About ABB Motors M3BM

High Voltage Induction Motors

From 110 to 2800 kW General safety regulations, specific agreements made for each work site and safety precautions shown in this
document must be observed at all times.
M3BM 315LKA 3GBM 312 810 - A Q A 003 etc. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A Motor type B Motor size C

M3BM motor catalogue ratings can be re-stamped as follows. Motor construction will not be changed but a new rating plate and data sheet can be created with variant code 002. In all the below cases or their combinations, please contact ABB for correct motor size and motor data. Bearing re-lubrication intervals as shown in this catalogue are valid also for re-stamped motors.

Output can be re-stamped downwards from the catalogue data, however the minimum output available for hazardous area motors is 110 kW

General Information

ABB's engineered motors for low
voltage variable speed drives range of up to 2240 kW.
This section includes preliminary standard technical
data and drawings with low voltage main terminal box.
The basic mechanical construction is the same as
described in Section 2. As with the engineered motors
all the motors with VSD are confi gured and optimized
for each order and application.

Installation

The standard motors in this Section are offered with limited optional features and accessories. The high voltage star point terminal box is shown below (option, variant code 750).

Stator frame90%

Stator frame

90%

Drain holes40%

Drain holes

40%

Terminal boxes60%

Terminal boxes

60%

Auxiliary boxes95%

Auxiliary boxes

95%

Why Chose Us?

Why Chose Us?

The customer is responsible for the preparation of the foundation. Certifi ed outline drawing is delivered with each purchase order. The motor's rotational direction will be as specifi ed in the order.

ABB offers several comprehensive ranges of AC motors and generators. We manufacture synchronous motors for even the most demanding applications, and a full range of low and high voltage induction motors. Our in-depth knowledge of virtually every type of industrial processing ensures we always specify the best solution for your needs.

Installation of main terminal box

The main terminal box is delivered with the machine in a separate box/slide package. The installation of the main
terminal box is performed according to these guidelines.
Scope of delivery
Scope of delivery
Check of foundation
Check of foundation
Erection of machines
Erection of machines
Alignment
Alignment
Image

Motor type M3BM 315LKA

Pole number 4

Mounting arrangement (IM code) IM B3 (IM 1001)

Rated output 110 kW

Product code 3GBM312810-AQA Variant codes if needed

Ordering information

When placing an order, please state the following minimum data in the order, as in the example.

The product code of the motor is composed in accordance with the following example.

Motor size

A B C D, E, F, G

M3BM 315LKA 3GBM 312 810 - AQ A 003 etc.

1 2 3 4 5 6 7 8 9 10 11 12 13 14


  1. Motor type

  2. Motor size

  3. Product code

  4. Mounting arrangement code

  5. Voltage and frequency code

  6. Generation code

  7. Variant codes


Explanation of the product code:

Positions 1 to 4

3GBM = Totally enclosed fan cooled squirrel cage motor with cast iron frame, high voltage

Positions 5 and 6

IEC-frame

31 = 315

35 = 355

40 = 400


Position 7

Speed (Pole pairs)

1 = 2 poles

2 = 4 poles

3 = 6 poles

4 = 8 poles

5 = 10 poles

6 = 12 poles


Position 8 to 10

Serial number


Position 11

- (dash)

Position 12

Mounting arrangement

A = Horizontal

B = Vertical


Position 13

Voltage and frequency code See table below

Position 14 Generation code A, B, C...

The product code must be, if needed, followed by variant codes.


Code letters for supplementing the product code - single speed motors


Code letter for voltage and frequency

Q

R

S

T

50 Hz

50 Hz

50 Hz

50 Hz

3000 V

3300 V

6600 V

6000 V

661f8be3db519661f8be3db51c
Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

18

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

Effi ciency

Power factor

Current

Speed
r/min

Full
load
100%

3/4
load
75%

Full
load
100%

3/4
load
75%

I

N

A

I

S

I

N

I

0

A

Output
kW

Motor type

Product  code

HV Process performance cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

The bullet in the product code indicates choice of mounting 
arrangement (see ordering information page).

3000 r/min = 2 poles

3000 V   50 Hz

132

M3BM

315 LKA

3GBM

311 810-•QA

2971

94.7

94.5

0.92

0.92

29

6.3

5

160

M3BM

315 LKB

3GBM

311 820-•QA

2971

94.9

94.8

0.92

0.92

35

6.5

6

200

M3BM

355 LKA

3GBM

351 810-•QA

2974

95.0

94.9

0.90

0.90

45

5.6

9

250

M3BM

355 LKB

3GBM

351 820-•QA

2975

95.5

95.5

0.90

0.90

56

6.1

11

315

M3BM

355 LKC

3GBM

351 830-•QA

2973

96.0

96.1

0.91

0.92

69

6.0

11

335

M3BM

355 LKD

3GBM

351 840-•QA

2972

96.0

96.1

0.91

0.92

74

6.0

12

355

4)

M3BM

400 LA

3GBM

401 510-•QA

2980

96.0

95.9

0.90

0.90

79

6.3

16

400

4)

M3BM

400 LB

3GBM

401 520-•QA

2978

96.2

96.2

0.91

0.91

88

6.2

15

450

4)

M3BM

400 LC

3GBM

401 530-•QA

2978

96.4

96.4

0.91

0.92

98

6.4

17

3000 r/min = 2 poles

3300 V   50 Hz

160

M3BM

315 LKA

3GBM

311 810-•RA

2969

94.9

94.9

0.92

0.92

32

6.1

5

200

M3BM

355 LKA

3GBM

351 810-•RA

2978

95.1

94.9

0.89

0.88

41

6.3

10

250

M3BM

355 LKB

3GBM

351 820-•RA

2975

95.5

95.5

0.90

0.90

51

6.1

10

315

M3BM

355 LKC

3GBM

351 830-•RA

2975

96.0

96.0

0.91

0.92

63

6.4

11

335

M3BM

355 LKD

3GBM

351 840-•RA

2975

96.2

96.2

0.91

0.92

67

6.5

11

355

4)

M3BM

400 LA

3GBM

401 510-•RA

2979

96.1

96.0

0.90

0.90

72

6.3

14

400

4)

M3BM

400 LB

3GBM

401 520-•RA

2978

96.2

96.1

0.91

0.91

80

6.2

14

450

4)

M3BM

400 LC

3GBM

401 530-•RA

2977

96.4

96.4

0.91

0.92

90

6.2

14

3000 r/min = 2 poles

6000 V   50 Hz

250

M3BM

355 LKA

3GBM

351 810-•TA

2975

95.3

95.4

0.91

0.91

28

6.1

5

280

M3BM

355 LKB

3GBM

351 820-•TA

2975

95.6

95.7

0.91

0.92

31

6.2

5

315

4)

M3BM

400 LA

3GBM

401 510-•TA

2981

95.5

95.4

0.89

0.88

36

6.4

8

355

4)

M3BM

400 LB

3GBM

401 520-•TA

2979

95.9

95.8

0.91

0.91

39

6.3

7

400

4)

M3BM

400 LC

3GBM

401 530-•TA

2978

96.0

96.0

0.91

0.91

44

6.2

8

425

4)

M3BM

400 LD

3GBM

401 540-•TA

2978

96.2

96.2

0.91

0.92

47

6.3

8

3000 r/min = 2 poles

6600 V   50 Hz

280

M3BM

355 LKA

3GBM

351 810-•SA

2976

95.5

95.6

0.91

0.92

28

6.5

5

315

4)

M3BM

400 LA

3GBM

401 510-•SA

2980

95.6

95.4

0.90

0.89

32

6.4

7

355

4)

M3BM

400 LB

3GBM

401 520-•SA

2980

95.8

95.7

0.91

0.91

36

6.3

7

400

4)

M3BM

400 LC

3GBM

401 530-•SA

2979

96.1

96.1

0.91

0.91

40

6.5

7

425

4)

M3BM

400 LD

3GBM

401 540-•SA

2978

96.2

96.2

0.91

0.92

42

6.5

7

1) 

The given values of load inertia assume two starts from cold and  

  one start from warm conditions in successions against quadratic  
  load torque with 90% of the rated torque at the rated speed and at  
  80% of the rated voltage.

2)

 Starting time with given values of the load inertia from cold  

  condition in succession against quadratic load torque with 90% of  
  the rated torque at the rated speed and at rated voltage.

3)

 The sound pressure levels are presented at no-load. The magnetic  

  noise level of 2- and 4-pole motors is typically low compared to  
  the fan noise, resulting no increase in the noise level on-load. The  
  variation and measuring tolerance of the fi gures is +3 dB(A).

4) 

Unidirectional fan construction as standard. Direction of rotation  

  must be stated when ordering, see variant codes 044 and 045.

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

 

19

1

Torque

Load
inertia

1)

kgm

2

Starting
time
cold 

2)

s

Maximum
stalling
time hot
s

Sound
pressure
level LP 

3)

dB(A)

T

N

Nm

T

S

T

N

T

max

T

N

Power
factor
cos 

ϕ

k

Rotor
inertia
kgm

2

Rotor
weight
kg

Motor
weight
kg

Output
kW

Motor type

3000 r/min = 2 poles

3000 V   50 Hz

132

M3BM

315 LKA

424

1.2

2.4

0.17

11

8

16

2.2

240

1240

78

160

M3BM

315 LKB

514

1.3

2.5

0.16

13

8

16

2.3

250

1270

78

200

M3BM

355 LKA

642

0.8

2.2

0.13

15

11

22

2.7

280

1680

83

250

M3BM

355 LKB

802

0.9

2.4

0.13

16

8

16

3.2

300

1780

83

315

M3BM

355 LKC

1012

1.0

2.2

0.13

20

8

16

5.0

390

2160

83

335

M3BM

355 LKD

1076

1.0

2.3

0.14

19

7

14

5.5

410

2240

83

355

4)

M3BM

400 LA

1138

0.9

2.4

0.13

26

10

20

6.4

460

2420

79

400

4)

M3BM

400 LB

1283

1.0

2.3

0.14

32

10

20

8.0

520

2670

79

450

4)

M3BM

400 LC

1443

1.1

2.3

0.14

34

9

18

9.6

580

2900

79

3000 r/min = 2 poles

3300 V   50 Hz

160

M3BM

315 LKA

515

1.2

2.3

0.17

13

8

16

2.3

250

1280

78

200

M3BM

355 LKA

641

0.9

2.5

0.13

16

10

20

2.7

280

1680

83

250

M3BM

355 LKB

802

0.9

2.4

0.13

18

9

16

3.2

300

1780

83

315

M3BM

355 LKC

1011

1.1

2.4

0.14

20

7

14

5.0

390

2140

83

335

M3BM

355 LKD

1075

1.1

2.4

0.13

21

7

14

5.5

410

2250

83

355

4)

M3BM

400 LA

1138

1.0

2.3

0.12

25

9

18

6.4

460

2440

79

400

4)

M3BM

400 LB

1283

1.0

2.3

0.13

27

9

18

8.0

520

2660

79

450

4)

M3BM

400 LC

1444

1.1

2.2

0.14

32

9

18

9.6

570

2910

79

3000 r/min = 2 poles

6000 V   50 Hz

250

M3BM

355 LKA

803

1.0

2.3

0.15

15

8

16

4.6

370

2010

83

280

M3BM

355 LKB

899

1.1

2.3

0.15

18

8

16

5.5

410

2200

83

315

4)

M3BM

400 LA

1009

1.0

2.4

0.14

23

10

20

5.6

430

2260

79

355

4)

M3BM

400 LB

1138

1.0

2.3

0.14

27

10

20

7.2

490

2500

79

400

4)

M3BM

400 LC

1283

1.0

2.3

0.14

31

10

20

8.0

520

2620

79

425

4)

M3BM

400 LD

1363

1.1

2.3

0.14

35

10

20

9.2

560

2800

79

3000 r/min = 2 poles

6600 V   50 Hz

280

M3BM

355 LKA

898

1.1

2.4

0.15

13

6

12

5.5

410

2190

83

315

4)

M3BM

400 LA

1009

1.0

2.4

0.14

24

10

20

5.6

430

2260

79

355

4)

M3BM

400 LB

1138

1.0

2.3

0.14

26

10

20

7.2

490

2490

79

400

4)

M3BM

400 LC

1282

1.1

2.4

0.14

30

9

18

8.0

520

2620

79

425

4)

M3BM

400 LD

1363

1.2

2.3

0.15

33

9

18

9.2

560

2800

79

HV Process performance cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

20

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

Effi ciency

Power factor

Current

Speed
r/min

Full
load
100%

3/4
load
75%

Full
load
100%

3/4
load
75%

I

N

A

I

S

I

N

I

0

A

Output
kW

Motor type

Product  code

The bullet in the product code indicates choice of mounting 
arrangement (see ordering information page).

HV Process performance cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

1) 

The given values of load inertia assume three starts from cold and 

  two starts from warm conditions in successions against quadratic 
  load torque with 90% of the rated torque at the rated speed and at 
  80% of the rated voltage.

2)

 Starting time with given values of the load inertia from cold  

  condition in succession against quadratic load torque with 90% of  
  the rated torque at the rated speed and at rated voltage.   
   

 

 

 

 

 

3)

 The sound pressure levels are presented at no-load. The magnetic  

  noise level of 2- and 4-pole motors is typically low compared to  
  the fan noise, resulting no increase in the noise level on-load. The  
  variation and measuring tolerance of the fi gures is +3 dB(A).

1500 r/min = 4 poles

3000 V   50 Hz

110

M3BM

315 LKA

3GBM

312 810-•QA

1488

94.7

94.3

0.83

0.79

27

6.2

11

132

M3BM

315 LKB

3GBM

312 820-•QA

1484

94.7

94.7

0.84

0.82

32

5.2

11

160

M3BM

315 LKC

3GBM

312 830-•QA

1485

95.0

94.9

0.87

0.85

37

6.3

11

200

M3BM

315 LKD

3GBM

312 840-•QA

1484

95.3

95.4

0.87

0.85

46

6.4

14

250

M3BM

355 LKA

3GBM

352 810-•QA

1490

95.6

95.4

0.83

0.80

61

6.2

23

315

M3BM

355 LKB

3GBM

352 820-•QA

1489

95.9

95.8

0.84

0.81

76

6.0

27

355

M3BM

355 LKC

3GBM

352 830-•QA

1488

96.1

96.0

0.84

0.82

85

6.1

29

400

M3BM

355 LKD

3GBM

352 840-•QA

1489

96.3

96.3

0.85

0.83

94

6.2

30

450

M3BM

400 LA

3GBM

402 510-•QA

1490

96.7

96.7

0.85

0.83

105

6.4

33

500

M3BM

400 LB

3GBM

402 520-•QA

1489

96.5

96.4

0.85

0.83

118

6.3

37

530

M3BM

400 LC

3GBM

402 530-•QA

1490

96.6

96.5

0.85

0.83

124

6.5

38

1500 r/min = 4 poles

3300 V   50 Hz

132

M3BM

315 LKA

3GBM

312 810-•RA

1488

94.9

94.6

0.81

0.76

30

6.2

13

160

M3BM

315 LKB

3GBM

312 820-•RA

1484

95.1

95.1

0.84

0.81

35

5.5

12

200

M3BM

315 LKC

3GBM

312 830-•RA

1484

95.3

95.4

0.87

0.85

42

6.4

12

250

M3BM

355 LKA

3GBM

352 810-•RA

1489

95.6

95.5

0.83

0.80

55

6.1

20

315

M3BM

355 LKB

3GBM

352 820-•RA

1490

95.8

95.7

0.83

0.79

70

6.4

27

355

M3BM

355 LKC

3GBM

352 830-•RA

1489

96.0

96.0

0.83

0.80

78

6.4

28

400

M3BM

355 LKD

3GBM

352 840-•RA

1489

96.3

96.2

0.85

0.82

86

6.4

28

450

M3BM

400 LA

3GBM

402 510-•RA

1489

96.7

96.7

0.85

0.83

96

6.1

29

500

M3BM

400 LB

3GBM

402 520-•RA

1490

96.5

96.4

0.85

0.82

107

6.5

35

530

M3BM

400 LC

3GBM

402 530-•RA

1489

96.6

96.5

0.85

0.84

112

6.4

34

1500 r/min = 4 poles

6000 V   50 Hz

250

M3BM

355 LKA

3GBM

352 810-•TA

1486

95.5

95.5

0.83

0.80

30

5.7

11

315

M3BM

355 LKB

3GBM

352 820-•TA

1487

96.0

95.9

0.83

0.79

38

6.4

15

355

M3BM

400 LA

3GBM

402 510-•TA

1489

96.2

96.2

0.85

0.83

42

6.2

13

400

M3BM

400 LB

3GBM

402 520-•TA

1489

96.4

96.4

0.85

0.83

47

6.4

15

450

M3BM

400 LC

3GBM

402 530-•TA

1489

96.2

96.2

0.86

0.84

53

6.2

16

500

M3BM

400 LD

3GBM

402 540-•TA

1490

96.4

96.4

0.85

0.83

59

6.4

18

1500 r/min = 4 poles

6600 V   50 Hz

250

M3BM

355 LKA

3GBM

352 810-•SA

1488

95.5

95.4

0.82

0.78

28

6.1

11

315

M3BM

355 LKB

3GBM

352 820-•SA

1487

95.9

95.9

0.83

0.80

35

6.3

13

355

M3BM

400 LA

3GBM

402 510-•SA

1489

96.2

96.2

0.85

0.83

38

6.1

12

400

M3BM

400 LB

3GBM

402 520-•SA

1489

96.3

96.3

0.85

0.83

43

6.2

13

450

M3BM

400 LC

3GBM

402 530-•SA

1489

96.2

96.2

0.85

0.83

48

6.4

15

500

M3BM

400 LD

3GBM

402 540-•SA

1490

96.4

96.4

0.85

0.83

53

6.5

17

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 

21

1

Torque

Load
inertia

1)

kgm

2

Starting
time
cold 

2)

s

Maximum
stalling
time hot
s

Sound
pressure
level LP 

3)

dB(A)

T

N

Nm

T

S

T

N

T

max

T

N

Power
factor
cos 

ϕ

k

Rotor
inertia
kgm

2

Rotor
weight
kg

Motor
weight
kg

Output
kW

Motor type

HV Process performance cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors 

 

IP 55 – IC 411 – Insulation class F, temperature rise class B

1500 r/min = 4 poles

3000 V   50 Hz

110

M3BM

315 LKA

706

1.6

2.3

0.21

50

9

20

2.0

220

1190

73

132

M3BM

315 LKB

849

1.3

1.9

0.21

53

10

20

2.0

220

1190

73

160

M3BM

315 LKC

1029

1.7

2.2

0.21

69

8

16

3.2

260

1190

73

200

M3BM

315 LKD

1287

1.8

2.2

0.21

78

7

14

3.9

300

1290

73

250

M3BM

355 LKA

1603

1.3

2.2

0.17

86

8

16

6.4

400

1860

74

315

M3BM

355 LKB

2021

1.3

2.1

0.17

92

7

14

7.6

450

1990

74

355

M3BM

355 LKC

2278

1.4

2.1

0.17

105

7

14

8.4

480

2090

74

400

M3BM

355 LKD

2566

1.4

2.2

0.17

120

7

14

10.4

550

2310

74

450

M3BM

400 LA

2855

1.5

2.1

0.16

125

6

12

14.4

660

2880

74

500

M3BM

400 LB

3206

1.5

2.1

0.16

134

6

12

14.4

660

2870

79

530

M3BM

400 LC

3398

1.5

2.1

0.16

147

6

12

16.2

710

3040

79

1500 r/min = 4 poles

3300 V   50 Hz

132

M3BM

315 LKA

847

1.7

2.3

0.21

70

10

20

2.0

220

1190

73

160

M3BM

315 LKB

1029

1.5

2.0

0.21

70

10

20

2.3

240

1260

73

200

M3BM

315 LKC

1287

1.8

2.2

0.21

78

7

14

3.9

300

1290

73

250

M3BM

355 LKA

1603

1.3

2.2

0.17

83

8

16

6.4

400

1860

74

315

M3BM

355 LKB

2019

1.5

2.3

0.17

87

6

12

7.6

450

1970

74

355

M3BM

355 LKC

2277

1.5

2.2

0.17

98

6

12

8.4

480

2070

74

400

M3BM

355 LKD

2565

1.5

2.2

0.17

107

6

12

10.4

550

2300

74

450

M3BM

400 LA

2886

1.4

2.0

0.16

114

6

12

13.2

620

2760

74

500

M3BM

400 LB

3025

1.5

2.1

0.16

140

6

10

14.4

660

2850

79

530

M3BM

400 LC

3398

1.5

2.1

0.16

143

6

11

16.8

730

3100

79

1500 r/min = 4 poles

6000 V   50 Hz

250

M3BM

355 LKA

1606

1.2

2.1

0.17

95

9

20

4.6

380

2010

74

315

M3BM

355 LKB

2022

1.5

2.3

0.17

110

7

18

5.9

440

2290

74

355

M3BM

400 LA

2277

1.4

2.1

0.17

110

7

14

12.0

600

2590

74

400

M3BM

400 LB

2565

1.5

2.1

0.17

111

6

12

13.2

640

2720

74

450

M3BM

400 LC

2887

1.5

2.1

0.17

122

6

12

14.4

670

2840

79

500

M3BM

400 LD

3206

1.6

2.1

0.17

138

6

12

15.6

700

2950

79

1500 r/min = 4 poles

6600 V   50 Hz

250

M3BM

355 LKA

1605

1.4

2.3

0.17

93

8

16

4.6

380

2010

74

315

M3BM

355 LKB

2023

1.4

2.3

0.17

105

7

14

5.9

440

2280

74

355

M3BM

400 LA

2277

1.4

2.1

0.17

110

7

14

12.0

600

2600

74

400

M3BM

400 LB

2566

1.5

2.1

0.17

125

7

14

13.2

640

2710

74

450

M3BM

400 LC

2886

1.6

2.1

0.17

128

6

12

14.4

670

2830

79

500

M3BM

400 LD

3205

1.6

2.1

0.17

141

6

12

15.6

700

2940

79

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

22

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

Effi ciency

Power factor

Current

Speed
r/min

Full
load
100%

3/4
load
75%

Full
load
100%

3/4
load
75%

I

N

A

I

S

I

N

I

0

A

Output
kW

Motor type

Product  code

The bullet in the product code indicates choice of mounting 
arrangement (see ordering information page).

HV Process performance cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

1000 r/min = 6 poles

3000 V   50 Hz

110

M3BM

315 LKA

3GBM

313 810-•QA

987

94.4

94.6

0.79

0.76

28

5.3

12

132

M3BM

315 LKB

3GBM

313 820-•QA

986

94.7

94.9

0.79

0.75

34

5.4

14

150

M3BM

315 LKC

3GBM

313 830-•QA

987

95.1

95.2

0.80

0.75

38

5.7

16

160

M3BM

355 LKA

3GBM

353 810-•QA

992

95.3

95.2

0.74

0.68

43

5.5

22

200

M3BM

355 LKB

3GBM

353 820-•QA

990

95.7

95.7

0.78

0.74

52

5.3

22

250

M3BM

355 LKC

3GBM

353 830-•QA

991

96.0

96.0

0.78

0.74

64

5.5

28

315

M3BM

400 L

3GBM

403 500-•QA

991

96.1

96.2

0.81

0.78

78

5.9

29

355

M3BM

400 LA

3GBM

403 510-•QA

991

96.3

96.4

0.82

0.79

87

5.9

31

400

M3BM

400 LB

3GBM

403 520-•QA

991

96.4

96.5

0.82

0.79

98

6.2

36

425

M3BM

400 LC

3GBM

403 530-•QA

991

96.4

96.5

0.82

0.79

104

6.3

38

1000 r/min = 6 poles

3300 V   50 Hz

110

M3BM

315 LKA

3GBM

313 810-•RA

988

94.5

94.6

0.79

0.74

26

5.6

11

132

M3BM

315 LKB

3GBM

313 820-•RA

987

94.7

94.9

0.79

0.75

31

5.6

13

150

M3BM

315 LKC

3GBM

313 830-•RA

987

95.1

95.2

0.80

0.75

35

5.7

15

160

M3BM

355 LKA

3GBM

353 810-•RA

992

95.3

95.1

0.73

0.67

40

5.7

21

200

M3BM

355 LKB

3GBM

353 820-•RA

990

95.6

95.7

0.78

0.74

47

5.3

20

250

M3BM

355 LKC

3GBM

353 830-•RA

990

95.9

96.0

0.79

0.75

58

5.3

24

315

M3BM

400 L

3GBM

403 500-•RA

990

96.0

96.2

0.81

0.79

71

5.7

25

355

M3BM

400 LA

3GBM

403 510-•RA

991

96.2

96.3

0.81

0.79

79

6.0

29

400

M3BM

400 LB

3GBM

403 520-•RA

991

96.4

96.5

0.82

0.79

89

6.0

32

425

M3BM

400 LC

3GBM

403 530-•RA

991

96.5

96.6

0.82

0.78

95

6.4

35

1000 r/min = 6 poles

6000 V   50 Hz

220

M3BM

355 LKA

3GBM

353 810-•TA

992

95.5

95.5

0.79

0.74

28

6.3

12

250

M3BM

355 LKB

3GBM

353 820-•TA

991

95.6

95.7

0.80

0.76

31

6.0

13

280

M3BM

400 L

3GBM

403 500-•TA

991

96.0

96.0

0.79

0.75

36

5.6

15

315

M3BM

400 LA

3GBM

403 510-•TA

992

96.2

96.1

0.79

0.75

40

5.8

17

355

M3BM

400 LB

3GBM

403 520-•TA

991

96.3

96.3

0.80

0.76

45

5.6

18

375

M3BM

400 LC

3GBM

403 530-•TA

991

96.3

96.3

0.79

0.76

47

5.8

19

1000 r/min = 6 poles

6600 V   50 Hz

250

M3BM

355 LKA

3GBM

353 810-•SA

992

95.6

95.6

0.79

0.75

29

6.3

13

280

M3BM

400 L

3GBM

403 500-•SA

991

95.9

95.9

0.78

0.74

33

5.6

14

315

M3BM

400 LA

3GBM

403 510-•SA

992

96.2

96.1

0.78

0.73

37

6.1

16

355

M3BM

400 LB

3GBM

403 520-•SA

991

96.3

96.3

0.79

0.75

41

5.8

17

375

M3BM

400 LC

3GBM

403 530-•SA

992

96.4

96.3

0.79

0.75

43

5.9

18

1)

 The given values of load inertia assume three starts from cold and

  two starts from warm conditions in successions against quadratic
  load torque with 90% of the rated torque at the rated speed and at
  80% of the rated voltage.

2)

 Starting time with given values of the load inertia from cold  

  condition in succession against quadratic load torque with 90% of  
  the rated torque at the rated speed and at rated voltage.

3)

 The sound pressure levels are presented at no-load. Sound level

  values of 6...12-pole motors at no-load are typically 1...3 dB(A)
  higher than the corresponding values at no-load. The variation and  
  measuring tolerance of the fi gures is +3 dB(A).

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

 

23

1

Torque

Load
inertia

1)

kgm

2

Starting
time
cold 

2)

s

Maximum
stalling
time hot
s

Sound
pressure
level LP 

3)

dB(A)

T

N

Nm

T

S

T

N

T

max

T

N

Power
factor
cos 

ϕ

k

Rotor
inertia
kgm

2

Rotor
weight
kg

Motor
weight
kg

Output
kW

Motor type

1000 r/min = 6 poles

3000 V   50 Hz

110

M3BM

315 LKA

1065

1.5

2.0

0.22

127

10

20

3.2

270

1170

65

132

M3BM

315 LKB

1278

1.6

2.1

0.22

144

9

18

3.7

290

1240

65

150

M3BM

315 LKC

1452

1.7

2.2

0.22

156

8

20

4.6

340

1380

65

160

M3BM

355 LKA

1541

1.5

2.1

0.19

178

10

20

4.8

350

1660

70

200

M3BM

355 LKB

1928

1.4

2.0

0.19

205

10

20

6.4

410

1850

70

250

M3BM

355 LKC

2410

1.5

2.0

0.19

275

10

20

8.0

480

2040

70

315

M3BM

400 L

3036

1.6

2.0

0.18

335

9

18

16.2

680

2500

75

355

M3BM

400 LA

3422

1.6

2.0

0.18

370

9

18

19.8

770

2740

75

400

M3BM

400 LB

3854

1.7

2.0

0.19

400

8

18

23.4

870

2970

75

425

M3BM

400 LC

4094

1.8

2.1

0.19

435

8

18

26.1

940

3130

75

1000 r/min = 6 poles

3300 V   50 Hz

110

M3BM

315 LKA

1064

1.6

2.1

0.22

136

10

20

3.2

270

1170

65

132

M3BM

315 LKB

1277

1.7

2.1

0.22

149

9

18

3.7

290

1240

65

150

M3BM

315 LKC

1452

1.7

2.2

0.22

175

9

20

4.6

340

1380

65

160

M3BM

355 LKA

1540

1.5

2.2

0.19

184

10

20

4.8

350

1660

70

200

M3BM

355 LKB

1928

1.4

2.0

0.19

204

10

20

6.4

410

1850

70

250

M3BM

355 LKC

2412

1.4

1.9

0.19

258

10

20

8.0

480

2040

70

315

M3BM

400 L

3038

1.5

1.9

0.18

350

9

18

16.2

680

2500

75

355

M3BM

400 LA

3422

1.6

2.0

0.19

382

9

18

19.8

770

2730

75

400

M3BM

400 LB

3855

1.7

2.0

0.19

435

9

18

23.4

870

2970

75

425

M3BM

400 LC

4094

1.8

2.1

0.19

445

8

18

26.1

940

3140

75

1000 r/min = 6 poles

6000 V   50 Hz

220

M3BM

355 LKA

2118

1.8

2.3

0.21

198

7

14

9.6

540

2160

70

250

M3BM

355 LKB

2409

1.7

2.1

0.21

210

7

14

10.4

570

2250

70

280

M3BM

400 L

2697

1.3

2.0

0.16

290

10

20

11.4

590

2530

75

315

M3BM

400 LA

3033

1.4

2.1

0.17

342

10

20

13.2

640

2700

75

355

M3BM

400 LB

3421

1.4

2.0

0.17

367

10

20

14.4

680

2820

75

375

M3BM

400 LC

3613

1.4

2.0

0.17

410

10

20

15.6

720

2940

75

1000 r/min = 6 poles

6600 V   50 Hz

250

M3BM

355 LKA

2408

1.8

2.2

0.21

193

6

12

10.4

570

2250

70

280

M3BM

400 L

2697

1.3

2.0

0.16

290

10

20

10.8

570

2460

75

315

M3BM

400 LA

3032

1.5

2.2

0.17

369

10

20

13.2

640

2700

75

355

M3BM

400 LB

3419

1.4

2.0

0.17

390

10

20

14.4

680

2820

75

375

M3BM

400 LC

3611

1.5

2.1

0.17

427

10

20

15.6

720

2940

75

HV Process performance cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

24

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

Effi ciency

Power factor

Current

Speed
r/min

Full
load
100%

3/4
load
75%

Full
load
100%

3/4
load
75%

I

N

A

I

S

I

N

I

0

A

Output
kW

Motor type

Product  code

750 r/min = 8 poles

3000 V   50 Hz

200

M3BM

400 LA

3GBM

404 510-•QA

742

95.1

95.2

0.79

0.76

51

5.3

21

220

M3BM

400 LB

3GBM

404 520-•QA

742

95.3

95.4

0.79

0.75

56

5.5

24

250

M3BM

400 LC

3GBM

404 530-•QA

742

95.4

95.6

0.80

0.76

63

5.4

25

280

M3BM

400 LD

3GBM

404 540-•QA

741

95.4

95.6

0.80

0.77

70

5.2

26

300

M3BM

400 LE

3GBM

404 540-•QA

741

95.6

95.8

0.80

0.77

75

5.4

29

750 r/min = 8 poles

3300 V   50 Hz

200

M3BM

400 LA

3GBM

404 510-•RA

742

95.0

95.2

0.79

0.76

46

5.2

19

220

M3BM

400 LB

3GBM

404 520-•RA

742

95.2

95.4

0.80

0.76

51

5.3

20

250

M3BM

400 LC

3GBM

404 530-•RA

741

95.3

95.6

0.80

0.78

57

5.0

21

280

M3BM

400 LD

3GBM

404 540-•RA

741

95.5

95.7

0.80

0.77

64

5.5

25

300

M3BM

400 LE

3GBM

404 550-•RA

741

95.5

95.7

0.80

0.77

69

5.5

27

750 r/min = 8 poles

6000 V   50 Hz

160

M3BM

400 LA

3GBM

404 510-•TA

741

94.4

94.4

0.76

0.71

21

5.2

10

180

M3BM

400 LB

3GBM

404 520-•TA

740

94.5

94.6

0.77

0.72

24

5.0

11

200

M3BM

400 LC

3GBM

404 530-•TA

740

94.7

94.8

0.77

0.73

26

5.1

12

220

M3BM

400 LD

3GBM

404 540-•TA

740

94.8

95.0

0.78

0.74

29

5.0

12

250

M3BM

400 LE

3GBM

404 550-•TA

740

95.1

95.1

0.77

0.72

33

5.3

15

750 r/min = 8 poles

6600 V   50 Hz

160

M3BM

400 LA

3GBM

404 510-•SA

741

94.5

94.4

0.76

0.71

20

5.4

9

180

M3BM

400 LB

3GBM

404 520-•SA

741

94.5

94.5

0.76

0.70

22

5.3

11

200

M3BM

400 LC

3GBM

404 530-•SA

740

94.6

94.8

0.78

0.74

24

4.8

10

220

M3BM

400 LD

3GBM

404 540-•SA

740

94.9

94.9

0.77

0.72

26

5.2

12

250

M3BM

400 LE

3GBM

404 550-•SA

741

95.1

95.1

0.76

0.71

30

5.5

14

1)

  The given values of load inertia assume three starts from cold and

  two starts from warm conditions in successions against quadratic
  load torque with 90% of the rated torque at the rated speed and at
  80% of the rated voltage.

2)

  Starting time with given values of the load inertia from cold  

  condition in succession against quadratic load torque with 90% of  
  the rated torque at the rated speed and at rated voltage.

3)

 The sound pressure levels are presented at no-load. Sound level

  values of 6...12-pole motors at no-load are typically 1...3 dB(A)
  higher than the corresponding values at no-load. The variation and  
  measuring tolerance of the fi gures is +3 dB(A).

HV Process performance cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

The bullet in the product code indicates choice of mounting 
arrangement (see ordering information page).

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

 

25

1

Torque

Load
inertia

1)

kgm

2

Starting
time
cold 

2)

s

Maximum
stalling
time hot
s

Sound
pressure
level LP 

3)

dB(A)

T

N

Nm

T

S

T

N

T

max

T

N

Power
factor
cos 

ϕ

k

Rotor
inertia
kgm

2

Rotor
weight
kg

Motor
weight
kg

Output
kW

Motor type

750 r/min = 8 poles

3000 V   50 Hz

200

M3BM

400 LA

2575

1.0

2.1

0.15

390

11

22

14.4

630

2370

75

220

M3BM

400 LB

2831

1.1

2.3

0.14

425

10

20

16.2

680

2490

75

250

M3BM

400 LC

3219

1.1

2.2

0.14

480

10

20

19.8

780

2730

75

280

M3BM

400 LD

3610

1.1

2.1

0.14

530

10

20

21.6

830

2830

75

300

M3BM

400 LE

3866

1.1

2.1

0.14

565

10

20

23.4

870

2960

75

750 r/min = 8 poles

3300 V   50 Hz

200

M3BM

400 LA

2575

1.0

2.1

0.15

390

11

22

14.4

630

2370

75

220

M3BM

400 LB

2833

1.1

2.1

0.14

425

10

20

16.2

680

2490

75

250

M3BM

400 LC

3223

1.0

2.0

0.14

480

11

22

19.8

780

2720

75

280

M3BM

400 LD

3607

1.1

2.2

0.14

530

9

18

21.6

830

2840

75

300

M3BM

400 LE

3865

1.1

2.2

0.14

565

9

18

23.4

870

2940

75

750 r/min = 8 poles

6000 V   50 Hz

160

M3BM

400 LA

2062

1.1

2.2

0.16

320

10

20

10.2

560

2380

75

180

M3BM

400 LB

2322

1.0

2.1

0.16

355

11

22

10.8

580

2450

75

200

M3BM

400 LC

2580

1.1

2.2

0.15

390

10

20

12.6

640

2620

75

220

M3BM

400 LD

2840

1.0

2.1

0.15

425

10

20

13.8

680

2740

75

250

M3BM

400 LE

3225

1.2

2.3

0.15

480

9

18

15.6

740

2920

75

750 r/min = 8 poles

6600 V   50 Hz

160

M3BM

400 LA

2061

1.1

2.3

0.16

320

10

20

10.8

580

2440

75

180

M3BM

400 LB

2319

1.1

2.3

0.16

355

10

20

10.8

580

2440

75

200

M3BM

400 LC

2583

1.0

2.0

0.16

390

11

22

12.6

640

2620

75

220

M3BM

400 LD

2838

1.1

2.2

0.15

425

10

20

13.8

680

2740

75

250

M3BM

400 LE

3223

1.2

2.3

0.15

480

9

18

15.6

740

2910

75

HV Process performance cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

26

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

Effi ciency

Power factor

Current

Speed
r/min

Full
load
100%

3/4
load
75%

Full
load
100%

3/4
load
75%

I

N

A

I

S

I

N

I

0

A

Output
kW

Motor type

Product  code

1)

  The given values of load inertia assume three starts from cold and

  two starts from warm conditions in successions against quadratic
  load torque with 90% of the rated torque at the rated speed and at
  80% of the rated voltage.

2)

  Starting time with given values of the load inertia from cold  

  condition in succession against quadratic load torque with 90% of  
  the rated torque at the rated speed and at rated voltage.

3)

 The sound pressure levels are presented at no-load. Sound level

  values of 6...12-pole motors at no-load are typically 1...3 dB(A)
  higher than the corresponding values at no-load. The variation and  
  measuring tolerance of the fi gures is +3 dB(A).

HV Process performance cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

The bullet in the product code indicates choice of mounting 
arrangement (see ordering information page).

600 r/min = 10 poles

3000 V   50 Hz

150

M3BM

400 LA

3GBM

405 510-•QA

593

94.1

93.9

0.72

0.67

43

4.7

22

160

M3BM

400 LB

3GBM

405 520-•QA

594

94.2

93.9

0.71

0.65

46

4.9

25

180

M3BM

400 LC

3GBM

405 530-•QA

593

94.3

94.0

0.71

0.65

51

4.9

27

200

M3BM

400 LD

3GBM

405 540-•QA

593

94.5

94.2

0.72

0.66

57

4.9

29

220

M3BM

400 LE

3GBM

405 550-•QA

593

94.6

94.2

0.71

0.64

63

5.2

35

600 r/min = 10 poles

3300 V   50 Hz

150

M3BM

400 LA

3GBM

405 510-•RA

593

94.1

93.8

0.71

0.66

39

4.8

20

160

M3BM

400 LB

3GBM

405 520-•RA

594

94.2

93.8

0.71

0.64

42

5.0

23

180

M3BM

400 LC

3GBM

405 530-•RA

593

94.3

94.0

0.71

0.65

47

4.9

25

200

M3BM

400 LD

3GBM

405 540-•RA

593

94.4

94.2

0.72

0.67

51

4.8

26

220

M3BM

400 LE

3GBM

405 550-•RA

593

94.5

94.3

0.72

0.66

57

5.0

30

500 r/min = 12 poles

3000 V   50 Hz

110

M3BM

400 LA

3GBM

406 510-•QA

494

93.1

92.8

0.66

0.60

34

4.3

19

120

M3BM

400 LB

3GBM

406 520-•QA

494

93.2

93.0

0.67

0.61

37

4.3

21

132

M3BM

400 LC

3GBM

406 530-•QA

494

93.4

93.1

0.67

0.61

41

4.3

23

150

M3BM

400 LD

3GBM

406 540-•QA

494

93.5

93.2

0.66

0.61

46

4.3

26

160

M3BM

400 LE

3GBM

406 550-•QA

494

93.7

93.2

0.66

0.59

50

4.6

29

500 r/min = 12 poles

3300 V   50 Hz

110

M3BM

400 LA

3GBM

406 510-•RA

494

93.1

92.7

0.66

0.60

31

4.4

18

120

M3BM

400 LB

3GBM

406 520-•RA

494

93.2

92.9

0.66

0.60

34

4.3

19

132

M3BM

400 LC

3GBM

406 530-•RA

494

93.4

93.1

0.67

0.61

37

4.3

21

150

M3BM

400 LD

3GBM

406 540-•RA

493

93.5

93.3

0.67

0.61

42

4.3

23

160

M3BM

400 LE

3GBM

406 550-•RA

494

93.7

93.3

0.66

0.60

45

4.4

25

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

 

27

1

Torque

Load
inertia

1)

kgm

2

Starting
time
cold 

2)

s

Maximum
stalling
time hot
s

Sound
pressure
level LP 

3)

dB(A)

T

N

Nm

T

S

T

N

T

max

T

N

Power
factor
cos 

ϕ

k

Rotor
inertia
kgm

2

Rotor
weight
kg

Motor
weight
kg

Output
kW

Motor type

600 r/min = 10 poles

3000 V   50 Hz

150

M3BM

400 LA

2415

1.0

2.0

0.15

515

13

26

16.2

680

2480

75

160

M3BM

400 LB

2574

1.1

2.1

0.15

545

12

24

17.1

710

2540

75

180

M3BM

400 LC

2897

1.1

2.1

0.15

605

11

22

18.9

750

2660

75

200

M3BM

400 LD

3220

1.1

2.1

0.14

670

11

22

21.6

830

2840

75

220

M3BM

400 LE

3540

1.2

2.2

0.14

730

10

20

23.4

880

2950

75

600 r/min = 10 poles

3300 V   50 Hz

150

M3BM

400 LA

2414

1.0

2.0

0.15

515

12

24

16.2

680

2470

75

160

M3BM

400 LB

2573

1.1

2.2

0.15

545

11

22

17.1

710

2530

75

180

M3BM

400 LC

2897

1.1

2.1

0.15

605

11

22

18.9

750

2650

75

200

M3BM

400 LD

3222

1.0

2.0

0.14

670

12

24

21.6

830

2830

75

220

M3BM

400 LE

3542

1.1

2.1

0.14

730

11

22

23.4

880

2950

75

500 r/min = 12 poles

3000 V   50 Hz

110

M3BM

400 LA

2126

1.0

2.0

0.14

595

14

28

16.2

680

2470

75

120

M3BM

400 LB

2320

1.0

2.0

0.14

650

14

28

18.0

730

2580

75

132

M3BM

400 LC

2553

1.0

2.0

0.14

710

14

28

19.8

780

2700

75

150

M3BM

400 LD

2902

1.1

2.0

0.14

795

13

26

21.6

830

2820

75

160

M3BM

400 LE

3092

1.1

2.1

0.14

845

12

24

24.3

900

3000

75

500 r/min = 12 poles

3300 V   50 Hz

110

M3BM

400 LA

2125

1.1

2.1

0.14

595

13

26

16.2

680

2460

75

120

M3BM

400 LB

2320

1.0

2.0

0.14

650

14

28

18.0

730

2580

75

132

M3BM

400 LC

2553

1.0

2.0

0.14

710

14

28

19.8

780

2700

75

150

M3BM

400 LD

2903

1.0

1.9

0.14

795

14

28

21.6

830

2820

75

160

M3BM

400 LE

3094

1.1

2.0

0.14

845

13

26

24.3

900

3000

75

HV Process performance cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

28

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

Effi ciency

Power factor

Current

Speed
r/min

Full
load
100%

3/4
load
75%

Full
load
100%

3/4
load
75%

I

N

A

I

S

I

N

I

0

A

Output
kW

Motor type

Product  code

Non-sparking and Dust Ignition Proof HV Cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

3000 r/min = 2 poles

3000 V 50 Hz

132

M3GM

315 LKA

3GGM

311 810-•QA

2971

94.7

94.5

0.92

0.92

29

6.3

5

160

M3GM

315 LKB

3GGM

311 820-•QA

2971

94.9

94.8

0.92

0.92

35

6.5

6

200

M3GM

355 LKA

3GGM

351 810-•QA

2974

95.0

94.9

0.9

0.9

45

5.6

9

250

M3GM

355 LKB

3GGM

351 820-•QA

2975

95.5

95.5

0.9

0.9

56

6.1

11

315

M3GM

355 LKC

3GGM

351 830-•QA

2973

96.0

96.1

0.91

0.92

69

6.0

11

335

M3GM

355 LKD

3GGM

351 840-•QA

2972

96.0

96.1

0.91

0.92

74

6.0

12

355

4)

M3GM

400 LA

3GGM

401 510-•QA

2980

96.0

95.9

0.9

0.9

79

6.3

16

400

4)

M3GM

400 LB

3GGM

401 520-•QA

2978

96.2

96.2

0.91

0.91

88

6.2

15

450

4)

M3GM

400 LC

3GGM

401 530-•QA

2978

96.4

96.4

0.91

0.92

98

6.4

17

3000 r/min = 2 poles

3300 V 50 Hz

160

M3GM

315 LKA

3GGM

311 810-•RA

2969

94.9

94.9

0.92

0.92

32

6.1

5

200

M3GM

355 LKA

3GGM

351 810-•RA

2978

95.1

94.9

0.89

0.88

41

6.3

10

250

M3GM

355 LKB

3GGM

351 820-•RA

2975

95.5

95.5

0.9

0.9

51

6.1

10

315

M3GM

355 LKC

3GGM

351 830-•RA

2975

96.0

96.0

0.91

0.92

63

6.4

11

335

M3GM

355 LKD

3GGM

351 840-•RA

2975

96.2

96.2

0.91

0.92

67

6.5

11

355

4)

M3GM

400 LA

3GGM

401 510-•RA

2979

96.1

96.0

0.9

0.9

72

6.3

14

400

4)

M3GM

400 LB

3GGM

401 520-•RA

2978

96.2

96.1

0.91

0.91

80

6.2

14

450

4)

M3GM

400 LC

3GGM

401 530-•RA

2977

96.4

96.4

0.91

0.92

90

6.2

14

3000 r/min = 2 poles

6000 V 50 Hz

250

M3GM

355 LKA

3GGM

351 810-•TA

2975

95.3

95.4

0.91

0.91

28

6.1

5

280

M3GM

355 LKB

3GGM

351 820-•TA

2975

95.6

95.7

0.91

0.92

31

6.2

5

315

4)

M3GM

400 LA

3GGM

401 510-•TA

2981

95.5

95.4

0.89

0.88

36

6.4

8

355

4)

M3GM

400 LB

3GGM

401 520-•TA

2979

95.9

95.8

0.91

0.91

39

6.3

7

400

4)

M3GM

400 LC

3GGM

401 530-•TA

2978

96.0

96

0.91

0.91

44

6.2

8

425

4)

M3GM

400 LD

3GGM

401 540-•TA

2978

96.2

96.2

0.91

0.92

47

6.3

8

3000 r/min = 2 poles

6600 V 50 Hz

280

M3GM

355 LKA

3GGM

351 810-•SA

2976

95.5

95.6

0.91

0.92

28

6.5

5

315

4)

M3GM

400 LA

3GGM

401 510-•SA

2980

95.6

95.4

0.9

0.89

32

6.4

7

355

4)

M3GM

400 LB

3GGM

401 520-•SA

2980

95.8

95.7

0.91

0.91

36

6.3

7

400

4)

M3GM

400 LC

3GGM

401 530-•SA

2979

96.1

96.1

0.91

0.91

40

6.5

7

425

4)

M3GM

400 LD

3GGM

401 540-•SA

2978

96.2

96.2

0.91

0.92

42

6.5

7

The bullet in the product code indicates choice of mounting 
arrangement (see ordering information page).

 

1)

 When ordering, the following variant codes have to be added to the product code acc. to  

 

 needs. The above prices INCLUDE the extra price acc. to variant code: 

 

 for non-sparking motors: 

 

 456 = Ex nA design, fulfi lling IEC 60079-15, with certifi cate.  

 

 

 

 480 = EEx nA, fulfi lling EN 50021.  

 for DIP motors:
 453 = DIP according to EN 50281-1-1, T= 125°C, category 2D, IP65  (for zone 21)  
 805 = DIP according to IEC 61241-1-1, T= 125°C, IP65  (for zone 21) 
 452 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP55  (for zone 22) 
 454 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP65  (for zone 22) 
 804 = DIP according to IEC 61241-1-1, T= 125°C, IP55  (for zone 22) 
 806 = DIP according to IEC 61241-1-1, T= 125°C, IP65  (for zone 22) 

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

 

29

1

Torque

Load
inertia

1)

kgm

2

Starting
time
cold 

2)

s

Maximum
stalling
time hot
s

Sound
pressure
level LP 

3)

dB(A)

T

N

Nm

T

S

T

N

T

max

T

N

Power
factor
cos 

ϕ

k

Rotor
inertia
kgm

2

Rotor
weight
kg

Motor
weight
kg

Output
kW

Motor type

Non-sparking and Dust Ignition Proof HV Cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

3000 r/min = 2 poles

3000 V 50 Hz

132

M3GM

315 LKA

424

1.2

2.4

0.17

11

8

16

2.2

240

1240

78

160

M3GM

315 LKB

514

1.3

2.5

0.17

13

8

16

2.3

250

1270

78

200

M3GM

355 LKA

642

0.8

2.2

0.13

15

11

22

2.7

280

1680

83

250

M3GM

355 LKB

802

0.9

2.4

0.13

16

8

16

3.2

300

1780

83

315

M3GM

355 LKC

1012

1.0

2.2

0.13

20

8

16

5

390

2160

83

335

M3GM

355 LKD

1076

1.0

2.3

0.14

19

7

14

5.5

410

2240

83

355

4)

M3GM

400 LA

1138

0.9

2.4

0.13

26

10

20

6.4

460

2420

79

400

4)

M3GM

400 LB

1283

1.0

2.3

0.14

32

10

20

8

520

2670

79

450

4)

M3GM

400 LC

1443

1.1

2.3

0.14

34

9

18

9.6

580

2900

79

3000 r/min = 2 poles

3300 V 50 Hz

160

M3GM

315 LKA

515

1.2

2.3

0.17

13

8

16

2.3

250

1280

78

200

M3GM

355 LKA

641

0.9

2.5

0.13

16

10

20

2.7

280

1680

83

250

M3GM

355 LKB

802

0.9

2.4

0.13

18

9

16

3.2

300

1780

83

315

M3GM

355 LKC

1011

1.1

2.4

0.14

20

7

14

5

390

2140

83

335

M3GM

355 LKD

1075

1.1

2.4

0.13

21

7

14

5.5

410

2250

83

355

4)

M3GM

400 LA

1138

1.0

2.3

0.13

25

9

18

6.4

460

2440

79

400

4)

M3GM

400 LB

1283

1.0

2.3

0.13

27

9

18

8

520

2660

79

450

4)

M3GM

400 LC

1444

1.1

2.2

0.14

32

9

18

9.6

570

2910

79

3000 r/min = 2 poles

6000 V 50 Hz

250

M3GM

355 LKA

803

1.0

2.3

0.15

15

8

16

4.6

370

2010

83

280

M3GM

355 LKB

899

1.1

2.3

0.15

18

8

16

5.5

410

2200

83

315

4)

M3GM

400 LA

1009

1.0

2.4

0.14

23

10

20

5.6

430

2260

79

355

4)

M3GM

400 LB

1138

1.0

2.3

0.14

27

10

20

7.2

490

2500

79

400

4)

M3GM

400 LC

1283

1.0

2.3

0.14

31

10

20

8

520

2620

79

425

4)

M3GM

400 LD

1363

1.1

2.3

0.14

35

10

20

9.2

560

2800

79

3000 r/min = 2 poles

6600 V 50 Hz

280

M3GM

355 LKA

898

1.1

2.4

0.15

13

6

12

5.5

410

2190

83

315

4)

M3GM

400 LA

1009

1.0

2.4

0.14

24

10

20

5.6

430

2260

79

355

4)

M3GM

400 LB

1138

1.0

2.3

0.14

26

10

20

7.2

490

2490

79

400

4)

M3GM

400 LC

1282

1.1

2.4

0.14

30

9

18

8

520

2620

79

425

4)

M3GM

400 LD

1363

1.2

2.3

0.15

33

9

18

9.2

560

2800

79

1)

  The given values of load inertia assume two starts from cold and  

  one start from warm conditions in successions against quadratic  
  load torque with 90% of the rated torque at the rated speed and  
  at 80% of the rated voltage.

2)

  Starting time with given values of the load inertia from cold  

  condition in succession against quadratic load torque with 90%  
  of the rated torque at the rated speed and at rated voltage.

3)

  The sound pressure levels are presented at no-load. The    

  magnetic noise level of 2- and 4-pole motors is typically low  
  compared to the fan noise, resulting no increase in the noise  
  level on-load. The variation and measuring tolerance of the 
  fi gures is + 3 dB(A).

4)

  Unidirectional fan construction as standard. Direction of rotation  

  must be stated when ordering, see variant codes 044 and 045.

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

30

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

Effi ciency

Power factor

Current

Speed
r/min

Full
load
100%

3/4
load
75%

Full
load
100%

3/4
load
75%

I

N

A

I

S

I

N

I

0

A

Output
kW

Motor type

Product  code

The bullet in the product code indicates choice 
of mounting arrangement 
(see ordering information page).

Non-sparking and Dust Ignition Proof HV Cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

1500 r/min = 4 poles

3000 V 50 Hz

110

M3GM

315 LKA

3GGM

312 810-•QA

1488

94.7

94.3

0.83

0.79

27

6.2

11

132

M3GM

315 LKB

3GGM

312 820-•QA

1484

94.7

94.7

0.84

0.82

32

5.2

11

160

M3GM

315 LKC

3GGM

312 830-•QA

1485

95.0

94.9

0.87

0.85

37

6.3

11

200

M3GM

315 LKD

3GGM

312 840-•QA

1484

95.3

95.4

0.87

0.85

46

6.4

14

250

M3GM

355 LKA

3GGM

352 810-•QA

1490

95.6

95.4

0.83

0.8

61

6.2

23

315

M3GM

355 LKB

3GGM

352 820-•QA

1489

95.9

95.8

0.84

0.81

76

6.0

27

355

M3GM

355 LKC

3GGM

352 830-•QA

1488

96.1

96.0

0.84

0.82

85

6.1

29

400

M3GM

355 LKD

3GGM

352 840-•QA

1489

96.3

96.3

0.85

0.83

94

6.2

30

450

M3GM

400 LA

3GGM

402 510-•QA

1490

96.7

96.7

0.85

0.83

105

6.4

33

500

M3GM

400 LB

3GGM

402 520-•QA

1489

96.5

96.4

0.85

0.83

118

6.3

37

530

M3GM

400 LC

3GGM

402 530-•QA

1490

96.6

96.5

0.85

0.83

124

6.5

38

1500 r/min = 4 poles

3300 V 50 Hz

132

M3GM

315 LKA

3GGM

312 810-•RA

1488

94.9

94.6

0.81

0.76

30

6.2

13

160

M3GM

315 LKB

3GGM

312 820-•RA

1484

95.1

95.1

0.84

0.81

35

5.5

12

200

M3GM

315 LKC

3GGM

312 830-•RA

1484

95.3

95.4

0.87

0.85

42

6.4

12

250

M3GM

355 LKA

3GGM

352 810-•RA

1489

95.6

95.5

0.83

0.8

55

6.1

20

315

M3GM

355 LKB

3GGM

352 820-•RA

1490

95.8

95.7

0.83

0.79

70

6.4

27

355

M3GM

355 LKC

3GGM

352 830-•RA

1489

96.0

96.0

0.83

0.8

78

6.4

28

400

M3GM

355 LKD

3GGM

352 840-•RA

1489

96.3

96.2

0.85

0.82

86

6.4

28

450

M3GM

400 LA

3GGM

402 510-•RA

1489

96.7

96.7

0.85

0.83

96

6.1

29

500

M3GM

400 LB

3GGM

402 520-•RA

1490

96.5

96.4

0.85

0.82

107

6.5

35

530

M3GM

400 LC

3GGM

402 530-•RA

1489

96.6

96.5

0.85

0.84

112

6.4

34

1500 r/min = 4 poles

6000 V 50 Hz

250

M3GM

355 LKA

3GGM

352 810-•TA

1486

95.5

95.5

0.83

0.8

30

5.7

11

315

M3GM

355 LKB

3GGM

352 820-•TA

1487

96.0

95.9

0.83

0.79

38

6.4

15

355

M3GM

400 LA

3GGM

402 510-•TA

1489

96.2

96.2

0.85

0.83

42

6.2

13

400

M3GM

400 LB

3GGM

402 520-•TA

1489

96.4

96.4

0.85

0.83

47

6.4

15

450

M3GM

400 LC

3GGM

402 530-•TA

1489

96.2

96.2

0.86

0.84

53

6.2

16

500

M3GM

400 LD

3GGM

402 540-•TA

1490

96.4

96.4

0.85

0.83

59

6.4

18

1500 r/min = 4 poles

6600 V 50 Hz

250

M3GM

355 LKA

3GGM

352 810-•SA

1488

95.5

95.4

0.82

0.78

28

6.1

11

315

M3GM

355 LKB

3GGM

352 820-•SA

1487

95.9

95.9

0.83

0.8

35

6.3

13

355

M3GM

400 LA

3GGM

402 510-•SA

1489

96.2

96.2

0.85

0.83

38

6.1

12

400

M3GM

400 LB

3GGM

402 520-•SA

1489

96.3

96.3

0.85

0.83

43

6.2

13

450

M3GM

400 LC

3GGM

402 530-•SA

1489

96.2

96.2

0.85

0.83

48

6.4

15

500

M3GM

400 LD

3GGM

402 540-•SA

1490

96.4

96.4

0.85

0.83

53

6.5

17

 

1)

 When ordering, the following variant codes have to be added to the product code acc. to   

  needs. The above prices INCLUDE the extra price acc. to variant code:   

  for non-sparking motors: 

 

 456 = Ex nA design, fulfi lling IEC 60079-15, with certifi cate. 

 

 

 

 480 = EEx nA, fulfi lling EN 50021.  

  for DIP motors:
  453 = DIP according to EN 50281-1-1, T= 125°C, category 2D, IP65  (for zone 21)  
 805 = DIP according to IEC 61241-1-1, T= 125°C, IP65  (for zone 21) 
 452 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP55  (for zone 22) 
 454 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP65  (for zone 22) 
 804 = DIP according to IEC 61241-1-1, T= 125°C, IP55  (for zone 22) 
 806 = DIP according to IEC 61241-1-1, T= 125°C, IP65  (for zone 22) 

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

 

31

1

Torque

Load
inertia

1)

kgm

2

Starting
time
cold 

2)

s

Maximum
stalling
time hot
s

Sound
pressure
level LP 

3)

dB(A)

T

N

Nm

T

S

T

N

T

max

T

N

Power
factor
cos 

ϕ

k

Rotor
inertia
kgm

2

Rotor
weight
kg

Motor
weight
kg

Output
kW

Motor type

1)

  The given values of load inertia assume three starts from cold and  

  two starts from warm conditions in successions against quadratic  
  load torque with 90% of the rated torque at the rated speed and  
  at 80% of the rated voltage.

2)

  Starting time with given values of the load inertia from cold  

  condition in succession against quadratic load torque with 90%  
  of the rated torque at the rated speed and at rated voltage.

3)

  The sound pressure levels are presented at no-load. The    

  magnetic noise level of 2- and 4-pole motors is typically low  
  compared to the fan noise, resulting no increase in the noise  
  level on-load. The variation and measuring tolerance of the fi gures
  is + 3 dB(A).

Non-sparking and Dust Ignition Proof HV Cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

1500 r/min = 4 poles

3000 V 50 Hz

110

M3GM

315 LKA

706

1.6

2.3

0.21

50

9

20

2

220

1190

73

132

M3GM

315 LKB

849

1.3

1.9

0.21

53

10

20

2

220

1190

73

160

M3GM

315 LKC

1029

1.7

2.2

0.21

69

8

16

3.2

260

1190

73

200

M3GM

315 LKD

1287

1.8

2.2

0.21

78

7

14

3.9

300

1290

73

250

M3GM

355 LKA

1603

1.3

2.2

0.17

86

8

16

6.4

400

1860

74

315

M3GM

355 LKB

2021

1.3

2.1

0.17

92

7

14

7.6

450

1990

74

355

M3GM

355 LKC

2278

1.4

2.1

0.17

105

7

14

8.4

480

2090

74

400

M3GM

355 LKD

2566

1.4

2.2

0.17

120

7

14

10.4

550

2310

74

450

M3GM

400 LA

2855

1.5

2.1

0.16

125

6

12

14.4

660

2880

74

500

M3GM

400 LB

3206

1.5

2.1

0.16

134

6

12

14.4

660

2870

79

530

M3GM

400 LC

3398

1.5

2.1

0.16

147

6

12

16.2

710

3040

79

1500 r/min = 4 poles

3300 V 50 Hz

132

M3GM

315 LKA

847

1.7

2.3

0.21

70

10

20

2

220

1190

73

160

M3GM

315 LKB

1029

1.5

2.0

0.21

70

10

20

2.3

240

1260

73

200

M3GM

315 LKC

1287

1.8

2.2

0.21

78

7

14

3.9

300

1290

73

250

M3GM

355 LKA

1603

1.3

2.2

0.17

83

8

16

6.4

400

1860

74

315

M3GM

355 LKB

2019

1.5

2.3

0.17

87

6

12

7.6

450

1970

74

355

M3GM

355 LKC

2277

1.5

2.2

0.17

98

6

12

8.4

480

2070

74

400

M3GM

355 LKD

2565

1.5

2.2

0.17

107

6

12

10.4

550

2300

74

450

M3GM

400 LA

2886

1.4

2.0

0.16

114

6

12

13.2

620

2760

74

500

M3GM

400 LB

3025

1.5

2.1

0.16

140

6

10

14.4

660

2850

79

530

M3GM

400 LC

3398

1.5

2.1

0.16

143

6

11

16.8

730

3100

79

1500 r/min = 4 poles

6000 V 50 Hz

250

M3GM

355 LKA

1606

1.2

2.1

0.17

95

9

20

4.6

380

2010

74

315

M3GM

355 LKB

2022

1.5

2.3

0.17

110

7

18

5.9

440

2290

74

355

M3GM

400 LA

2277

1.4

2.1

0.17

110

7

14

12

600

2590

74

400

M3GM

400 LB

2565

1.5

2.1

0.17

111

6

12

13.2

640

2720

74

450

M3GM

400 LC

2887

1.5

2.1

0.17

122

6

12

14.4

670

2840

79

500

M3GM

400 LD

3206

1.6

2.1

0.17

138

6

12

15.6

700

2950

79

1500 r/min = 4 poles

6600 V 50 Hz

250

M3GM

355 LKA

1605

1.4

2.3

0.17

93

8

16

4.6

380

2010

74

315

M3GM

355 LKB

2023

1.4

2.3

0.17

105

7

14

5.9

440

2280

74

355

M3GM

400 LA

2277

1.4

2.1

0.17

110

7

14

12

600

2600

74

400

M3GM

400 LB

2566

1.5

2.1

0.17

125

7

14

13.2

640

2710

74

450

M3GM

400 LC

2886

1.6

2.1

0.17

128

6

12

14.4

670

2830

79

500

M3GM

400 LD

3205

1.6

2.1

0.17

141

6

12

15.6

700

2940

79

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

32

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

Effi ciency

Power factor

Current

Speed
r/min

Full
load
100%

3/4
load
75%

Full
load
100%

3/4
load
75%

I

N

A

I

S

I

N

I

0

A

Output
kW

Motor type

Product  code

Non-sparking and Dust Ignition Proof HV Cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

The bullet in the product code indicates choice 
of mounting arrangement 
(see ordering information page).

 

1)

 When ordering, the following variant codes have to be added to the product code acc. to  

 needs. The above prices INCLUDE the extra price acc. to variant code: 

 for non-sparking motors: 

 

 456 = Ex nA design, fulfi lling IEC 60079-15, with certifi cate.  

 

 

 480 = EEx nA, fulfi lling EN 50021.  

 for DIP motors:
 453 = DIP according to EN 50281-1-1, T= 125°C, category 2D, IP65  (for zone 21)  
 805 = DIP according to IEC 61241-1-1, T= 125°C, IP65  (for zone 21) 
 452 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP55  (for zone 22) 
 454 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP65  (for zone 22) 
 804 = DIP according to IEC 61241-1-1, T= 125°C, IP55  (for zone 22) 
 806 = DIP according to IEC 61241-1-1, T= 125°C, IP65  (for zone 22) 

1000 r/min = 6 poles

3000 V 50 Hz

110

M3GM

315 LKA

3GGM

313 810-•QA

987

94.4

94.6

0.79

0.76

28

5.3

12

132

M3GM

315 LKB

3GGM

313 820-•QA

986

94.7

94.9

0.79

0.75

34

5.4

14

150

M3GM

315 LKC

3GGM

313 830-•QA

987

95.1

95.2

0.8

0.75

38

5.7

16

160

M3GM

355 LKA

3GGM

353 810-•QA

992

95.3

95.2

0.74

0.68

43

5.5

22

200

M3GM

355 LKB

3GGM

353 820-•QA

990

95.7

95.7

0.78

0.74

52

5.3

22

250

M3GM

355 LKC

3GGM

353 830-•QA

991

96.0

96.0

0.78

0.74

64

5.5

28

315

M3GM

400 L

3GGM

403 500-•QA

991

96.1

96.2

0.81

0.78

78

5.9

29

355

M3GM

400 LA

3GGM

403 510-•QA

991

96.3

96.4

0.82

0.79

87

5.9

31

400

M3GM

400 LB

3GGM

403 520-•QA

991

96.4

96.5

0.82

0.79

98

6.2

36

425

M3GM

400 LC

3GGM

403 530-•QA

991

96.4

96.5

0.82

0.79

104

6.3

38

1000 r/min = 6 poles

3300 V 50 Hz

110

M3GM

315 LKA

3GGM

313 810-•RA

988

94.5

94.6

0.79

0.74

26

5.6

11

132

M3GM

315 LKB

3GGM

313 820-•RA

987

94.7

94.9

0.79

0.75

31

5.6

13

150

M3GM

315 LKC

3GGM

313 830-•RA

987

95.1

95.2

0.8

0.75

35

5.7

15

160

M3GM

355 LKA

3GGM

353 810-•RA

992

95.3

95.1

0.73

0.67

40

5.7

21

200

M3GM

355 LKB

3GGM

353 820-•RA

990

95.6

95.7

0.78

0.74

47

5.3

20

250

M3GM

355 LKC

3GGM

353 830-•RA

990

95.9

96.0

0.79

0.75

58

5.3

24

315

M3GM

400 L

3GGM

403 500-•RA

990

96

96.2

0.81

0.79

71

5.7

25

355

M3GM

400 LA

3GGM

403 510-•RA

991

96.2

96.3

0.81

0.79

79

6.0

29

400

M3GM

400 LB

3GGM

403 520-•RA

991

96.4

96.5

0.82

0.79

89

6.0

32

425

M3GM

400 LC

3GGM

403 530-•RA

991

96.5

96.6

0.82

0.78

95

6.4

35

1000 r/min = 6 poles

6000 V 50 Hz

220

M3GM

355 LKA

3GGM

353 810-•TA

992

95.5

95.5

0.79

0.74

28

6.3

12

250

M3GM

355 LKB

3GGM

353 820-•TA

991

95.6

95.7

0.8

0.76

31

6

13

280

M3GM

400 L

3GGM

403 500-•TA

991

96

96

0.79

0.75

36

5.6

15

315

M3GM

400 LA

3GGM

403 510-•TA

992

96.2

96.1

0.79

0.75

40

5.8

17

355

M3GM

400 LB

3GGM

403 520-•TA

991

96.3

96.3

0.8

0.76

45

5.6

18

375

M3GM

400 LC

3GGM

403 530-•TA

991

96.3

96.3

0.79

0.76

47

5.8

19

1000 r/min = 6 poles

6600 V 50 Hz

250

M3GM

355 LKA

3GGM

353 810-•SA

992

95.6

95.6

0.79

0.75

29

6.3

13

280

M3GM

400 L

3GGM

403 500-•SA

991

95.9

95.9

0.78

0.74

33

5.6

14

315

M3GM

400 LA

3GGM

403 510-•SA

992

96.2

96.1

0.78

0.73

37

6.1

16

355

M3GM

400 LB

3GGM

403 520-•SA

991

96.3

96.3

0.79

0.75

41

5.8

17

375

M3GM

400 LC

3GGM

403 530-•SA

992

96.4

96.3

0.79

0.75

43

5.9

18

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

 

33

1

Torque

Load
inertia

1)

kgm

2

Starting
time
cold 

2)

s

Maximum
stalling
time hot
s

Sound
pressure
level LP 

3)

dB(A)

T

N

Nm

T

S

T

N

T

max

T

N

Power
factor
cos 

ϕ

k

Rotor
inertia
kgm

2

Rotor
weight
kg

Motor
weight
kg

Output
kW

Motor type

1)

  The given values of load inertia assume three starts from cold and  

  two starts from warm conditions in successions against quadratic  
  load torque with 90% of the rated torque at the rated speed and  
  at 80% of the rated voltage.

2)

  Starting time with given values of the load inertia from cold  

  condition in succession against quadratic load torque with 90%  
  of the rated torque at the rated speed and at rated voltage.

3)

 The sound pressure levels are presented at no-load. Sound level

  values of 6...12-pole motors at no-load are typically 1...3 dB(A)
  higher than the corresponding values at no-load. The variation and  
  measuring tolerance of the fi gures is +3 dB(A).

Non-sparking and Dust Ignition Proof HV Cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

1000 r/min = 6 poles

3000 V 50 Hz

110

M3GM

315 LKA

1065

1.5

2.0

0.22

127

10

20

3.2

270

1170

65

132

M3GM

315 LKB

1278

1.6

2.1

0.22

144

9

18

3.7

290

1240

65

150

M3GM

315 LKC

1452

1.7

2.2

0.22

156

8

20

4.6

340

1380

65

160

M3GM

355 LKA

1541

1.5

2.1

0.19

178

10

20

4.8

350

1660

70

200

M3GM

355 LKB

1928

1.4

2.0

0.19

205

10

20

6.4

410

1850

70

250

M3GM

355 LKC

2410

1.5

2.0

0.19

275

10

20

8

480

2040

70

315

M3GM

400 L

3036

1.6

2.0

0.18

335

9

18

16.2

680

2500

75

355

M3GM

400 LA

3422

1.6

2.0

0.18

370

9

18

19.8

770

2740

75

400

M3GM

400 LB

3854

1.7

2.0

0.19

400

8

18

23.4

870

2970

75

425

M3GM

400 LC

4094

1.8

2.1

0.19

435

8

18

26.1

940

3130

75

1000 r/min = 6 poles

3300 V 50 Hz

110

M3GM

315 LKA

1064

1.6

2.1

0.22

136

10

20

3.2

270

1170

65

132

M3GM

315 LKB

1277

1.7

2.1

0.22

149

9

18

3.7

290

1240

65

150

M3GM

315 LKC

1452

1.7

2.2

0.22

175

9

20

4.6

340

1380

65

160

M3GM

355 LKA

1540

1.5

2.2

0.19

184

10

20

4.8

350

1660

70

200

M3GM

355 LKB

1928

1.4

2.0

0.19

204

10

20

6.4

410

1850

70

250

M3GM

355 LKC

2412

1.4

1.9

0.19

258

10

20

8

480

2040

70

315

M3GM

400 L

3038

1.5

1.9

0.18

350

9

18

16.2

680

2500

75

355

M3GM

400 LA

3422

1.6

2.0

0.19

382

9

18

19.8

770

2730

75

400

M3GM

400 LB

3855

1.7

2.0

0.19

435

9

18

23.4

870

2970

75

425

M3GM

400 LC

4094

1.8

2.1

0.19

445

8

18

26.1

940

3140

75

1000 r/min = 6 poles

6000 V 50 Hz

220

M3GM

355 LKA

2118

1.8

2.3

0.21

198

7

14

9.6

540

2160

70

250

M3GM

355 LKB

2409

1.7

2.1

0.21

210

7

14

10.4

570

2250

70

280

M3GM

400 L

2697

1.3

2.0

0.17

290

10

20

11.4

590

2530

75

315

M3GM

400 LA

3033

1.4

2.1

0.17

342

10

20

13.2

640

2700

75

355

M3GM

400 LB

3421

1.4

2.0

0.17

367

10

20

14.4

680

2820

75

375

M3GM

400 LC

3613

1.4

2.0

0.17

410

10

20

15.6

720

2940

75

1000 r/min = 6 poles

6600 V 50 Hz

250

M3GM

355 LKA

2408

1.8

2.2

0.21

193

6

12

10.4

570

2250

70

280

M3GM

400 L

2697

1.3

2.0

0.17

290

10

20

10.8

570

2460

75

315

M3GM

400 LA

3032

1.5

2.2

0.17

369

10

20

13.2

640

2700

75

355

M3GM

400 LB

3419

1.4

2.0

0.17

390

10

20

14.4

680

2820

75

375

M3GM

400 LC

3611

1.5

2.1

0.17

427

10

20

15.6

720

2940

75

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

34

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

Effi ciency

Power factor

Current

Speed
r/min

Full
load
100%

3/4
load
75%

Full
load
100%

3/4
load
75%

I

N

A

I

S

I

N

I

0

A

Output
kW

Motor type

Product  code

Non-sparking and Dust Ignition Proof HV Cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

750 r/min = 8 poles

3000 V 50 Hz

200

M3GM

400 LA

3GGM

404 510-•QA

742

95.1

95.2

0.79

0.76

51

5.3

21

220

M3GM

400 LB

3GGM

404 520-•QA

742

95.3

95.4

0.79

0.75

56

5.5

24

250

M3GM

400 LC

3GGM

404 530-•QA

742

95.4

95.6

0.8

0.76

63

5.4

25

280

M3GM

400 LD

3GGM

404 540-•QA

741

95.4

95.6

0.8

0.77

70

5.2

26

300

M3GM

400 LE

3GGM

404 540-•QA

741

95.6

95.8

0.8

0.77

75

5.4

29

750 r/min = 8 poles

3300 V 50 Hz

200

M3GM

400 LA

3GGM

404 510-•RA

742

95

95.2

0.79

0.76

46

5.2

19

220

M3GM

400 LB

3GGM

404 520-•RA

742

95.2

95.4

0.8

0.76

51

5.3

20

250

M3GM

400 LC

3GGM

404 530-•RA

741

95.3

95.6

0.8

0.78

57

5.0

21

280

M3GM

400 LD

3GGM

404 540-•RA

741

95.5

95.7

0.8

0.77

64

5.5

25

300

M3GM

400 LE

3GGM

404 550-•RA

741

95.5

95.7

0.8

0.77

69

5.5

27

750 r/min = 8 poles

6000 V 50 Hz

160

M3GM

400 LA

3GGM

404 510-•TA

741

94.4

94.4

0.76

0.71

21

5.2

10

180

M3GM

400 LB

3GGM

404 520-•TA

740

94.5

94.6

0.77

0.72

24

5.0

11

200

M3GM

400 LC

3GGM

404 530-•TA

740

94.7

94.8

0.77

0.73

26

5.1

12

220

M3GM

400 LD

3GGM

404 540-•TA

740

94.8

95.0

0.78

0.74

29

5.0

12

250

M3GM

400 LE

3GGM

404 550-•TA

740

95.1

95.1

0.77

0.72

33

5.3

15

750 r/min = 8 poles

6600 V 50 Hz

160

M3GM

400 LA

3GGM

404 510-•SA

741

94.5

94.4

0.76

0.71

20

5.4

9

180

M3GM

400 LB

3GGM

404 520-•SA

741

94.5

94.5

0.76

0.7

22

5.3

11

200

M3GM

400 LC

3GGM

404 530-•SA

740

94.6

94.8

0.78

0.74

24

4.8

10

220

M3GM

400 LD

3GGM

404 540-•SA

740

94.9

94.9

0.77

0.72

26

5.2

12

250

M3GM

400 LE

3GGM

404 550-•SA

741

95.1

95.1

0.76

0.71

30

5.5

14

The bullet in the product code indicates choice of mounting 
arrangement (see ordering information page).

 

1)

 When ordering, the following variant codes have to be added to the product code acc. to  

 

 needs. The above prices INCLUDE the extra price acc. to variant code: 

 

 for non-sparking motors: 

 

 456 = Ex nA design, fulfi lling IEC 60079-15, with certifi cate.  

 

 

 

 480 = EEx nA, fulfi lling EN 50021.  

 for DIP motors:
 453 = DIP according to EN 50281-1-1, T= 125°C, category 2D, IP65  (for zone 21)  
 805 = DIP according to IEC 61241-1-1, T= 125°C, IP65  (for zone 21) 
 452 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP55  (for zone 22) 
 454 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP65  (for zone 22) 
 804 = DIP according to IEC 61241-1-1, T= 125°C, IP55  (for zone 22) 
 806 = DIP according to IEC 61241-1-1, T= 125°C, IP65  (for zone 22) 

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

 

35

1

Torque

Load
inertia

1)

kgm

2

Starting
time
cold 

2)

s

Maximum
stalling
time hot
s

Sound
pressure
level LP 

3)

dB(A)

T

N

Nm

T

S

T

N

T

max

T

N

Power
factor
cos 

ϕ

k

Rotor
inertia
kgm

2

Rotor
weight
kg

Motor
weight
kg

Output
kW

Motor type

Non-sparking and Dust Ignition Proof HV Cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

750 r/min = 8 poles

3000 V 50 Hz

200

M3GM

400 LA

2575

1.0

2.1

0.15

390

11

22

14.4

630

2370

75

220

M3GM

400 LB

2831

1.1

2.3

0.14

425

10

20

16.2

680

2490

75

250

M3GM

400 LC

3219

1.1

2.2

0.14

480

10

20

19.8

780

2730

75

280

M3GM

400 LD

3610

1.1

2.1

0.14

530

10

20

21.6

830

2830

75

300

M3GM

400 LE

3866

1.1

2.1

0.14

565

10

20

23.4

870

2960

75

750 r/min = 8 poles

3300 V 50 Hz

200

M3GM

400 LA

2575

1.0

2.1

0.15

390

11

22

14.4

630

2370

75

220

M3GM

400 LB

2833

1.1

2.1

0.14

425

10

20

16.2

680

2490

75

250

M3GM

400 LC

3223

1.0

2.0

0.14

480

11

22

19.8

780

2720

75

280

M3GM

400 LD

3607

1.1

2.2

0.14

530

9

18

21.6

830

2840

75

300

M3GM

400 LE

3865

1.1

2.2

0.14

565

9

18

23.4

870

2940

75

750 r/min = 8 poles

6000 V 50 Hz

160

M3GM

400 LA

2062

1.1

2.2

0.16

320

10

20

10.2

560

2380

75

180

M3GM

400 LB

2322

1.0

2.1

0.16

355

11

22

10.8

580

2450

75

200

M3GM

400 LC

2580

1.1

2.2

0.15

390

10

20

12.6

640

2620

75

220

M3GM

400 LD

2840

1.0

2.1

0.15

425

10

20

13.8

680

2740

75

250

M3GM

400 LE

3225

1.2

2.3

0.15

480

9

18

15.6

740

2920

75

750 r/min = 8 poles

6600 V 50 Hz

160

M3GM

400 LA

2061

1.1

2.3

0.16

320

10

20

10.8

580

2440

75

180

M3GM

400 LB

2319

1.1

2.3

0.16

355

10

20

10.8

580

2440

75

200

M3GM

400 LC

2583

1.0

2.0

0.16

390

11

22

12.6

640

2620

75

220

M3GM

400 LD

2838

1.1

2.2

0.15

425

10

20

13.8

680

2740

75

250

M3GM

400 LE

3223

1.2

2.3

0.15

480

9

18

15.6

740

2910

75

1)

  The given values of load inertia assume three starts from cold and  

  two starts from warm conditions in successions against quadratic  
  load torque with 90% of the rated torque at the rated speed and  
  at 80% of the rated voltage.

2)

  Starting time with given values of the load inertia from cold  

  condition in succession against quadratic load torque with 90%  
  of the rated torque at the rated speed and at rated voltage.

3)

 The sound pressure levels are presented at no-load. Sound level

  values of 6...12-pole motors at no-load are typically 1...3 dB(A)
  higher than the corresponding values at no-load. The variation and  
  measuring tolerance of the fi gures is +3 dB(A).

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

36

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

Effi ciency

Power factor

Current

Speed
r/min

Full
load
100%

3/4
load
75%

Full
load
100%

3/4
load
75%

I

N

A

I

S

I

N

I

0

A

Output
kW

Motor type

Product  code

Non-sparking and Dust Ignition Proof HV Cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

600 r/min = 10 poles

3000 V 50 Hz

150

M3GM

400 LA

3GGM

405 510-•QA

593

94.1

93.9

0.72

0.67

43

4.7

22

160

M3GM

400 LB

3GGM

405 520-•QA

594

94.2

93.9

0.71

0.65

46

4.9

25

180

M3GM

400 LC

3GGM

405 530-•QA

593

94.3

94.0

0.71

0.65

51

4.9

27

200

M3GM

400 LD

3GGM

405 540-•QA

593

94.5

94.2

0.72

0.66

57

4.9

29

220

M3GM

400 LE

3GGM

405 550-•QA

593

94.6

94.2

0.71

0.64

63

5.2

35

600 r/min = 10 poles

3300 V 50 Hz

150

M3GM

400 LA

3GGM

405 510-•RA

593

94.1

93.8

0.71

0.66

39

4.8

20

160

M3GM

400 LB

3GGM

405 520-•RA

594

94.2

93.8

0.71

0.64

42

5.0

23

180

M3GM

400 LC

3GGM

405 530-•RA

593

94.3

94.0

0.71

0.65

47

4.9

25

200

M3GM

400 LD

3GGM

405 540-•RA

593

94.4

94.2

0.72

0.67

51

4.8

26

220

M3GM

400 LE

3GGM

405 550-•RA

593

94.5

94.3

0.72

0.66

57

5.0

30

500 r/min = 12 poles

3000 V 50 Hz

110

M3GM

400 LA

3GGM

406 510-•QA

494

93.1

92.8

0.66

0.6

34

4.3

19

120

M3GM

400 LB

3GGM

406 520-•QA

494

93.2

93.0

0.67

0.61

37

4.3

21

132

M3GM

400 LC

3GGM

406 530-•QA

494

93.4

93.1

0.67

0.61

41

4.3

23

150

M3GM

400 LD

3GGM

406 540-•QA

494

93.5

93.2

0.66

0.61

46

4.3

26

160

M3GM

400 LE

3GGM

406 550-•QA

494

93.7

93.2

0.66

0.59

50

4.6

29

500 r/min = 12 poles

3300 V 50 Hz

110

M3GM

400 LA

3GGM

406 510-•RA

494

93.1

92.7

0.66

0.6

31

4.4

18

120

M3GM

400 LB

3GGM

406 520-•RA

494

93.2

92.9

0.66

0.6

34

4.3

19

132

M3GM

400 LC

3GGM

406 530-•RA

494

93.4

93.1

0.67

0.61

37

4.3

21

150

M3GM

400 LD

3GGM

406 540-•RA

493

93.5

93.3

0.67

0.61

42

4.3

23

160

M3GM

400 LE

3GGM

406 550-•RA

494

93.7

93.3

0.66

0.6

45

4.4

25

The bullet in the product code indicates choice of mounting 
arrangement (see ordering information page).

 

1)

 When ordering, the following variant codes have to be added to the product code acc. to  

 

 needs. The above prices INCLUDE the extra price acc. to variant code: 

 

 for non-sparking motors: 

 

 456 = Ex nA design, fulfi lling IEC 60079-15, with certifi cate.  

 

 

 

 480 = EEx nA, fulfi lling EN 50021.  

 for DIP motors:
 453 = DIP according to EN 50281-1-1, T= 125°C, category 2D, IP65  (for zone 21)  
 805 = DIP according to IEC 61241-1-1, T= 125°C, IP65  (for zone 21) 
 452 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP55  (for zone 22) 
 454 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP65  (for zone 22) 
 804 = DIP according to IEC 61241-1-1, T= 125°C, IP55  (for zone 22) 
 806 = DIP according to IEC 61241-1-1, T= 125°C, IP65  (for zone 22) 

Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

 

37

1

Torque

Load
inertia

1)

kgm

2

Starting
time
cold 

2)

s

Maximum
stalling
time hot
s

Sound
pressure
level LP 

3)

dB(A)

T

N

Nm

T

S

T

N

T

max

T

N

Power
factor
cos 

ϕ

k

Rotor
inertia
kgm

2

Rotor
weight
kg

Motor
weight
kg

Output
kW

Motor type

Non-sparking and Dust Ignition Proof HV Cast iron motors

Technical data for totally enclosed squirrel
cage three phase motors  

IP 55 – IC 411 – Insulation class F, temperature rise class B

600 r/min = 10 poles

3000 V 50 Hz

150

M3GM

400 LA

2415

1

2

0.15

515

13

26

16.2

680

2480

75

160

M3GM

400 LB

2574

1.1

2.1

0.15

545

12

24

17.1

710

2540

75

180

M3GM

400 LC

2897

1.1

2.1

0.15

605

11

22

18.9

750

2660

75

200

M3GM

400 LD

3220

1.1

2.1

0.14

670

11

22

21.6

830

2840

75

220

M3GM

400 LE

3540

1.2

2.2

0.14

730

10

20

23.4

880

2950

75

600 r/min = 10 poles

3300 V 50 Hz

150

M3GM

400 LA

2414

1.0

2.0

0.15

515

12

24

16.2

680

2470

75

160

M3GM

400 LB

2573

1.1

2.2

0.15

545

11

22

17.1

710

2530

75

180

M3GM

400 LC

2897

1.1

2.1

0.15

605

11

22

18.9

750

2650

75

200

M3GM

400 LD

3222

1.0

2.0

0.14

670

12

24

21.6

830

2830

75

220

M3GM

400 LE

3542

1.1

2.1

0.14

730

11

22

23.4

880

2950

75

500 r/min = 12 poles

3000 V 50 Hz

110

M3GM

400 LA

2126

1.0

2.0

0.14

595

14

28

16.2

680

2470

75

120

M3GM

400 LB

2320

1.0

2.0

0.14

650

14

28

18

730

2580

75

132

M3GM

400 LC

2553

1.0

2.0

0.14

710

14

28

19.8

780

2700

75

150

M3GM

400 LD

2902

1.1

2.0

0.14

795

13

26

21.6

830

2820

75

160

M3GM

400 LE

3092

1.1

2.1

0.14

845

12

24

24.3

900

3000

75

500 r/min = 12 poles

3300 V 50 Hz

110

M3GM

400 LA

2125

1.1

2.1

0.14

595

13

26

16.2

680

2460

75

120

M3GM

400 LB

2320

1.0

2.0

0.14

650

14

28

18

730

2580

75

132

M3GM

400 LC

2553

1.0

2.0

0.14

710

14

28

19.8

780

2700

75

150

M3GM

400 LD

2903

1.0

1.9

0.14

795

14

28

21.6

830

2820

75

160

M3GM

400 LE

3094

1.1

2.0

0.14

845

13

26

24.3

900

3000

75

1)

  The given values of load inertia assume three starts from cold and  

  two starts from warm conditions in successions against quadratic  
  load torque with 90% of the rated torque at the rated speed and  
  at 80% of the rated voltage.

2)

  Starting time with given values of the load inertia from cold  

  condition in succession against quadratic load torque with 90%  
  of the rated torque at the rated speed and at rated voltage.

3)

 The sound pressure levels are presented at no-load. Sound level

  values of 6...12-pole motors at no-load are typically 1...3 dB(A)
  higher than the corresponding values at no-load. The variation and  
  measuring tolerance of the fi gures is +3 dB(A).

background image

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 

43

1

HV Process performance cast iron motors in brief, basic design

Motor size

315

355

400

Stator

Material

Cast iron EN-GJL-250 EN 1561

Paint colour shade

Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G / RAL 5014

Paint thickness

Two-pack epoxy paint, thickness

 

≥ 

180

 

µm

Bearing end shields

Material

Cast iron EN-GJL-200 SFS-EN 1561

Paint colour shade

Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G / RAL 5014

Paint thickness

Two-pack epoxy paint, thickness

 

≥ 

180 µm

Bearings

D-end  

2 pole

6316-M/C3 

6316-M/C3

6317-M/C3

           

4-12 pole

6319/C3

6322/C3

6324/C3

N-end

2 pole

6316-M/C3 

6316-M/C3

6317-M/C3

4-12 pole

6316/C3

6316/C3

6319/C3

Axially-locked

Inner bearing cover

As standard, locked at D-end

bearings

Bearing seal

As standard, labyrinth seal in both ends.

Lubrication

Regreasable bearings

Regreasing nipples M10x1 DIN 71412 A

SPM-nipples

As standard

Rating and 

Material

Stainless steel, EN 10088, thickness 0.5 mm.

lubrication plate

Terminal box

Frame material

Structural steel S235JRG2-EN-10025, thickness 3 mm.

Cover material

Structural steel S235JRG2-EN-10025, thickness 3 mm.

Cover screws material

Yellow passivated.

Connections

Cable entries

Blind gland plate.

Terminals

3 terminals for connection with cable lugs (not included)

Grounding locations on frame and terminal box (in- and outside)

Fan

Material

Glass fi bre reinforced plastic, aluminum or polyprophene fan with metal hub. 

Direction of rotation / fans (IC411)

- plastic bidirectional

- aluminum birectional

- polyprophene fan unidirectional.

Fan cover

Material

Steel

Paint colour shade

Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G / RAL 5014

Paint thickness

Two-pack epoxy polyester powder, thickness

 

≥ 

80 µm

Stator winding

Material

Form wound copper, VPI

Insulation

Insulation class F

Winding protection

PT100, 6 pieces

Rotor winding

Material

Pressure die-cast aluminum

Balancing method

Half key balancing as standard

Key ways

Open key way

Heating elements

On request

1x200 W

1x200 W

1x300 W

Drain holes

Standard, open on delivery.

Enclosure

IP 55, higher protection as option.

Cooling method

IC 411

661f8dd0ed5ec661f8dd0ed5ee
Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B

38

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

HV Process performance cast iron motors - Variant codes

Code

Variant

Motor size

 

1)

315

355

400

Balancing

423

Balanced without key

P

P

P

424

Full key balancing.

P

P

P

Bearings and lubrication

036

Transport lock for bearings.

P

P

P

037

Roller bearing at D-end.

P

P

P

107

Bearing mounted PT100 resistance elements.

P

P

P

796

Grease nipples JIS B 1575 PT 1/8 Type A.

P

P

P

Branch standard designs

178

Stainless steel/acid proof bolts.

P

P

P

398

Motor designed for ambient temperature -20°C to -40°C.

P

P

P

Cooling system

44

Unidirectional fan, clockwise seen from D-end.

NA

NA

P

45

Unidirectional fan, counter clockwise seen from D-end.

NA

NA

P

68

Metal fan (for M3BM motors only).

P

P

P

791

Stainless steel fan cover (horizontal motor only).

R

R

R

Drain holes

65

Plugged existing drain holes.

P

P

P

448

Draining holes with metal plugs.

P

P

P

Heating elements

450

Heating element, 100-120 V.

P

P

P

451

Heating element, 200-240 V.

P

P

P

Painting

114

Special paint colour, standard grade.

P

P

P

751

Paint system 2, UV-light.

P

P

P

Surface treatment acc. to the ISO 12944, category 3 with direct UV radiation.

752

Paint system 4, offshore.

P

P

P

Surface treatment acc. to the ISO 12944, category C5 & Norsok M-501.

Protection

005

Protective roof, vertical motor, shaft down.

P

P

P

401

Protective roof, horizontal motor (for M3BM motors only).

R

R

R

158

Degree of protection IP 65.

P

P

P

403

Degree of protection IP 56.

P

P

P

Rating & instruction plates

002

Restamping output and voltage, continuous duty. For M3GM on request.

P

P

P

Standards and regulations

010

Fulfi lling CSA Safety Certifi cate.

P

P

P

778

GOST Export/Import Certifi cate (Russia).

P

P

P

782

Fulfi lling CQST Certifi cate requirements (China) (for M3GM motors only).

R

R

R

Terminal box

021

Terminal box LHS (seen from D-end).

P

P

P

447

Top mounted separate auxiliary box for heating elements (for M3BM motors only). 

P

P

P

750

Star point terminal box.

P

P

P

Testing

Routine test report included as standard.

146

Type test with report for motor from specifi c delivery patch.

P

P

P

147

Type test with report for motor from specifi c delivery patch, customer witnessed.

P

P

P

Variable speed drives

701

Insulated bearing at N-end.

P

P

P

P   =  New manufacture only. 
NA  =  Not applicable.

1)

 Certain variant codes cannot be used simultaneously.

R   =  On request.

661f8f27a130f661f8f27a1311
HV Process performance cast iron motors

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 

39

1

HV Process performance cast iron motors

 

Sizes 315-400

Dimension drawings 

Foot-mounted: IM B3 (IM 1001)

Motor

Poles

A

AA

AB

AC

AD

B

B'

B''

BA

BB

C    

 D

DB

E

EG

size

315 LK

2

508

100

590

656

555

508

560

710

336

851

216

65

M20

140

42

315 LK

4-6

508

100

590

656

555

508

560

710

336

851

216

90

M24

170

52

355 LK

2

610

120

700

746

627

630

710

900

447

1077

254

70

M20

140

42

355 LK

4-6

610

120

700

746

627

630

710

900

447

1077

254

100

M24

210

51

400 L

2

710

150

840

834

627

900

1000

-

410

1156

224

80

M20

170

42

400 L

4-12

710

150

840

834

627

900

1000

-

410

1156

224

110

M24

210

50

Tolerances:
A, B, C ± 

0,8 

F ISO 

h9

D ISO 

m6 

H +0 

-1.0

 

The above table gives the main dimensions in mm.

For detailed drawings please see our web-pages 'www.
abb.com/motors&drives' or contact us.

Motor

Poles

F

G

GA

GD

H

HA

HC

HD

K

L

LD

O

size

315 LK

2

18

58

69

11

315

40

643

1055

28

1490

355

115

315 LK

4-6

25

81

95

14

315

40

643

1055

28

1521

385

115

355 LK

2

20

62.5

74.5

12

355

52

725

1138

35

1764

398

130

355 LK

4-6

28

90

106

16

355

52

725

1138

35

1834

468

130

400 L

2

22

71

85

14

400

45

814

1225

35

1851

458

150

400 L

4-12

28

100

116

16

400

45

814

1225

35

1891

498

150

661f8f22d8ad8661f8f22d8adb
HV Process performance cast iron motors

40

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

HV Process performance cast iron motors

 

Sizes 315-400

Dimension drawings 

Flange-mounted; IM V1 (IM 3011)

Motor

Poles

AC

D

DB

E

EG

F

G

GA

GD

HB

size

315 LK

4-6

725

100

M24

210

51

28

90

106

16

731

355 LK

4-6

725

100

M24

210

51

28

90

106

16

774

400 L

4-12

814

110

M24

210

50

28

100

106

16

816

The above table gives the main dimensions in mm.

For detailed drawings please see our web-pages 'www.
abb.com/motors&drives' or contact us.

Tolerances:

D ISO 

m6 

 N  ISO js6 (315_)

F ISO 

h9 

 

Motor 

Poles

L

LA

LB

LD

M

N

O

P

S

T

size

315 LK

4-6

1834

25

1624

1116

600

550

130

800

23

6

355 LK

4-6

1834

25

1624

1386

740

680

130

800

23

6

400 L

4-12

1891

26

1681

1400

940

880

150

1000

28

6

661f90847142e661f90847142f
Typical exploded view of high voltage cast iron motor

42

 

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006

1

HV Process performance cast iron motor construction

Typical exploded view of high voltage cast iron motor

 

1 Stator 

frame

 2  End 

shield, 

D-end

 

Screws for end shield, D-end

 

End shield, N-end 

 

Screws for end shield, N-end

 

Rotor with shaft 

 7  Key, 

D-end 

 8  Main 

terminal 

box 

 9  Middle 

box 

 

 

  10 

Screws for terminal box cover 

  11 

Outer bearing cover, D-end 

  12 

Valve disc with labyrinth seal, D-end

 13  Bearing, 

D-end 

 14  Inner 

bearing 

cover

  15 

Screws for bearing cover, D-end

  16 

Outer bearing cover, N-end

 

 

 

17 

Valve disc with labyrinth seal, D-end 

 18  Bearing, 

N-end

  19 

Inner bearing cover, N-end

 20  Spring
  21 

Screws for bearing cover, N-end

 22  Fan
 23  Fan 

cover

  24 

Screws for fan cover

 25  Rating 

plate

 26  Lubrication 

plate

 27  Auxiliary 

terminal 

box

  28 

Grease nipple, D-end

  29 

Grease nipple, N-end

 30  SPM 

nipple, 

D-end

  31 

SPM nipple, N-end

661f908e581b1661f908e581b5
Typical exploded view of high voltage cast iron motor

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 

41

1

L

LL

Accessories

 

 

Frame size

Set code

315

SLRA315-M3

355

SLRA355-M3

400

SLRA400-M3

The set code has to be mentioned on order.

Sole plates

With anchor bolts for concrete foundation

Frame size

Set code

315

SOPL315A-M3

355

SOPL355A-M3

400

SOPL400A-M3

The set code has to be mentioned on order.

Frame size

Set code

315

FOST315-M3

355

FOST355-M3

400

FOST400-M3

The set code has to be mentioned on order.

Foundation studs

Slide rails

Without anchor bolts

Frame size

Set code

315

SOPL315-M3

355

SOPL355-M3

400

SOPL400-M3

The set code has to be mentioned on order.

Sole plates

Protective roof 

Motor

Pole

L

LL

size

number

315 LK

4-6

1591

1421

355 LK

4-6

1951

1741

400 L

4-6

2008

1798

Variant code 005

Partner 1
Partner 1
Partner 1
Partner 1

Order Quantity OfOne PieceTwo PiecesThree PiecesAll Quantitesis acceptable.

We accept all quantities even one piece that we would send for you. There are big stock these brands' parts in our warehouse and one or two pieces is not a problem for us. Of courser, the larger quantity, the better price. We suggest to order as more as possible.
Payment could be Telegraphic Transfer or Paypal Or credit card or even Alipay. We have over 30 years experience on international trade and lots of the payment we can accept. We will send you our accounts once you have make decision on which way will pay us.
Delivery way is by various ways such as by air, or by sea or door to door by courier. For small quantity, we suggest to send by air or by courier because the sea freight agents don't like small weight cargos over 100kg below. Also, the transport time is depends on the way that you choose and we will give you some advice when you have place orders.
We are one of many agents for worldwide famous brands in China and we guarantee all these brand parts that we selling is genuine. There is QR code in the parts and all you could check from the brands' official website.

Your Feedback Is Very Import To Us.

Please fill the required field.
Please fill the required field.

Product Gallery

Contact Information

Yantai Bonway Manufacturer Co.ltd

Phone:   +86 535 6330966

Whatsapp/Wechat: +86 185 6380 6647 

Adress: No.160 Changjiang Road, Yantai, Shandong, China(264006)

Please fill the required field.
Please fill the required field.

Search