AC Motors

Industrial Axial Flow Fan Electric motor

Industrial Axial Flow Fan Electric motor

SF series special motors for axial flow fans, pure copper coils, cast iron shells, ball bearings, can be used in environments below 70-80 degrees at room temperature, and a one-year warranty for use in normal environments.

SFG Axial Fan Special Motor 220v Exhaust Fan/Induced Draft Fan/Smoke Machine/Three-phase Motor High Speed 380v.

Moisture and oil proof bearings
Seiko-made brand new bearings, wear-resistant, corrosion-resistant, not easy to rust, double stability in both directions, high-efficiency work is not afraid of shocks

The axial flow fan is mainly composed of impeller, casing, motor and other parts, and the bracket is connected with the casing air duct by using section steel. The impeller and casing of the anti-corrosion axial flow fan are made of glass fiber reinforced plastic, and other axial flow fans are generally made of steel plate. The gas conveyed by the axial flow fan should be free of significant dust, viscous and fibrous materials; the temperature of the direct-connected motor should not exceed 40°C, and the temperature of the belt-driven type should not exceed 60°C. The amount of dust in the conveying gas must not exceed 150mg/m3. When the impeller rotates, the gas enters the impeller axially from the air inlet, and is pushed by the blades on the impeller to increase the energy of the gas, and then flows into the guide vane. The guide vane changes the deflected airflow into an axial flow, and at the same time introduces the gas into the diffuser tube, further converts the kinetic energy of the gas into pressure energy, and introduces it into the working pipeline.

Industrial Axial Flow Fan Electric motor

Axial fans have a very wide range of uses. They are airflow in the same direction as the axis of the blades. For example, electric fans and air conditioners outside fans are fans that operate in axial flow. It is called "axial flow" because the gas flows parallel to the fan axis. T35 wall type axial flow fans are usually used in occasions with high flow requirements and low pressure requirements. The fire-fighting axial fan fixes the position and moves the air. The axial flow fan is mainly composed of the fan impeller and the casing. The structure is simple but the data requirements are very high.

Axial fans are usually used in occasions with higher flow requirements and lower pressure requirements. The axial fan fixes the position and moves the air. The axial flow fan is mainly composed of the fan impeller and the casing. The structure is simple but the data requirements are very high.

Scope of fan application: This series of fans is suitable for conveying non-explosive, non-corrosive and non-obviously dusty gas. The ambient temperature should not exceed 60 degrees Celsius. It is widely used in general factories, warehouses, offices, and houses for ventilation or strong heating. It can also be installed in series with a longer interval in the exhaust pipe to increase the pressure in the pipe. The casing can also be used as a free fan.

Full oil valve SG-16-180-R, SG-24-180-R, SG-32-180-R, PF-90-10, SG-16-90-R, SG-24-90-R, SG -32-90-R, PF-100-10, SG-16-90-L, SG-24-90-L, SG-32-90-L, PF-125-10, SG-16-180-L , SG-24-180-L, SG-32-180-L, PF-150-10
Ball directional valve, solenoid ball valve 23QDF6K-4/31.5E24,24QDF6K-4/31.5E24, 23QDF6B-4/31.5E24, 24QDF6B-4/31.5E24, 23QDF6K-31.5E24, 24QDF6K-31.5E24, 23QDF6B-31.5E24 , 24QDF6B-31.5E24, 23QDF6K-4/31.5B220, 24QDF6K-4/31.5B220, 23QDF6B-4/31.5B220, 24QDF6B-4/31.5B220, 23QDF6K-31.5B220, 24QDF6K-31.5B220,23QDF6B-31.5B220, 24QDF6B -31.5B220
Taiwan CHYUN TSEH Motor C01-43B0, C02-43B0, C03-43B0, C05-43B0, C7B-43B0, C10-43B0, C15-43B0, C20-43B0
Motor CO1-43BO, CO2-43BO, CO3-43BO, CO5-43BO, C7B-43BO, C1O-43BO, C15-43BO, C2O-43BO
Assemble directly with the oil pump, reducing space, low noise, strong power, quality assurance, and reliable performance
Air cooler AF0510-CA, AF1025-CA, AH0608T-CA, AH0608TL-CA, AH1012T-CA, AH1417T-CA, AH1470T-CA
Quantitative vane pump DS-11FR, DS-12FR, DS-13FR, DS-14FR, DS-11p, DS-12p, DS-13p, DS-14p
FB1-05FR, FB1-07FR, FB1-12FR
FB1-F3R-10, FB1-F5R-10, FB1-F7R-10, FB1-F12R-10
Vane pump HVP-FAI-F5R, HVP-FAI-F8R, HVP-FAI-F11R, HVP-FAI-F13R, HVP-FAI-L5R, HVP-FAI-L8R, HVP-FAI-L11R, HVP-FAI-L13

Industrial Axial Flow Fan Electric motor
Taiwan FURNAN vane pump HVP-FAI-5R, HVP-FAI-8R, HVP-FAI-11R, HVP-FAI-13R
Taiwan EALY quantitative pump FA1-F02R-10, FA1-F05R-10, FA1-F08R-10, FA1-F13R-10
Taiwan COMPASS vane pump FA1-05FR, FA1-08FR, FA1-11FR

The explosion-proof axial fan is a new type of fan designed on the basis of BT30-11 in the 1980s in my country. Compared with the BT30-11 fan, it has obvious advantages: ① The structure is more reasonable;   ② The performance is greatly improved, full pressure The effectiveness is 89.5%; ③ The noise is lower, and the noise (compared to A sound level) is reduced by 3.6dB (A).

Explosion-proof axial fan is suitable for conveying flammable, explosive and non-corrosive gas, and the ambient temperature should not exceed 60℃. It is widely used in general factories, warehouses, offices, and houses for ventilation or strong heat dissipation. It can also be longer The exhaust pipes are installed in series at intervals to increase the pressure in the pipes, and the motor can be used as a free fan when the motor is removed.

Product overview of mine axial fan:
Axial fans are very useful, that is, the airflow in the same direction as the axis of the blades, such as electric fans, air conditioner fans, which operate in axial flow mode. It is called "axial flow" because the gas flows parallel to the fan axis. Axial fans are usually used in occasions with higher flow requirements and lower pressure requirements. The axial fan fixes the position and moves the air. The axial flow fan is mainly composed of the fan impeller and the casing. The structure is simple but the data requirements are very high. Ordinary axial fans can be used for ventilation in general factories, warehouses, offices, residences, etc., and can also be used for air coolers (air coolers), evaporators, condensers, spray droplets, etc., and there are also mine shafts. Flow fan, anti-corrosion, explosion-proof axial flow fan adopts anti-corrosion materials and explosion-proof measures, and is matched with explosion-proof motor. It can be used to transport explosive, volatile, and corrosive gas. The gas delivered by axial flow fan should be dust-free and non-sticky. And fibrous materials; the temperature of the motor directly connected type does not exceed 40℃, and the temperature of the belt drive type does not exceed 60℃. The amount of dust in the conveying gas shall not exceed 150mg/m3. The axial flow fan is mainly composed of impeller, casing, motor and other parts, and the bracket is connected with the casing air duct by means of steel. The impeller and casing of the anti-corrosion axial flow fan are made of glass fiber reinforced plastic, and other axial flow fans are generally made of steel plate.
Working principle of mine axial fan:

Industrial Axial Flow Fan Electric motor
When the impeller rotates, the gas enters the impeller axially from the air inlet, is pushed by the blades on the impeller to increase the energy of the gas, and then flows into the guide vane. The guide vane changes the deflected airflow into an axial flow, and at the same time introduces the gas into the diffuser tube, further converts the kinetic energy of the gas into pressure energy, and then introduces it into the working pipeline. The blades of an axial flow fan work similarly to the wings of an airplane. However, the latter applies lift upwards on the wings and supports the weight of the aircraft, while the axial flow fan fixes the position and moves the air. The cross section of an axial fan is generally a wing section. The blade can be fixed in position, or it can rotate around its longitudinal axis. The angle between the blades and the airflow or the distance between the blades may not be adjustable or adjustable. Changing the blade angle or pitch is one of the main advantages of axial fans. A small blade pitch angle produces a lower flow rate, while increasing the pitch can produce a higher flow rate. The axial flow fan can change the blade pitch when the fan is running (this is quite similar to a helicopter rotor), thereby changing the flow rate accordingly. This is called adjustable moving blade (VP) axial flow fan.
Product Classification of Axial Fans for Mines:
Classified by material: steel fan, glass fiber reinforced plastic fan, plastic fan, PP fan, PVC fan, magnesium alloy fan, aluminum fan, stainless steel fan, etc.
Classified by purpose: explosion-proof fans, anti-corrosion fans, explosion-proof and anti-corrosion fans, axial fans and other types.
Classified according to usage requirements: pipeline type, wall type, post type, fixed type, rainproof and dustproof type, mobile type, motor external type, etc.
According to the installation method, it can be divided into: belt drive type and motor direct connection type.
Application occasions of mine axial fan:
It can be used for ventilation or heat dissipation in metallurgy, chemical industry, light industry, food, medical equipment, mechanical equipment and civil buildings. If the casing is removed, it can also be used as a free fan, or in a longer exhaust duct The internal compartments are installed in series to increase the wind pressure in the pipeline.

Industrial Axial Flow Fan Electric motor

Features of Mine Axial Fans:
Small axial flow fan: low power consumption, fast heat dissipation, low noise, energy saving and environmental protection, etc. Due to its small size, it is more useful.
Large-scale axial flow fans have the characteristics of simple structure, stability and reliability, low noise, large air volume, and function selection.
Product parameters of mine axial fan:
Material Steel
Fan pressure High pressure fan
Type Press-in
Performance Low noise fan
Purpose Coal mine, metal mine, tunnel ventilation

This series of motors have the advantages of high efficiency, energy saving, good performance, low noise, low vibration, high reliability, power level and installation size in line with I.E.C. standards, easy use and maintenance, etc. The protection level is IP44. Y2 series (IP54) is a fully enclosed self-fan-cooled squirrel-cage three-phase asynchronous motor, which is a new basic series designed uniformly in my country. It is a new generation product designed on the basis of Y series motors in China in the 1990s. It has the advantages of high efficiency, energy saving, good performance, low noise, low vibration, high reliability, power and installation dimensions in line with the International Electrotechnical Commission (I.E.C) standard, easy use and maintenance, etc. The protection level is IP54.
This series of motors are widely used in axial fans. Due to the adoption of the most advanced design ideas and methods, first-class craftsmanship, high-quality electrical materials, and low-noise bearings, the motor noise is greatly reduced. In addition, it also has a high degree of protection and performance. Low consumption, high efficiency, high insulation level, energy saving, stable starting, low vibration, excellent performance and other outstanding advantages, the power level and installation dimensions comply with the International Electrotechnical Commission (IEC) standards.

Industrial Axial Flow Fan Electric motor

YSF-7114, YSF-7124, YSF-8024, YSF-8026, YF90S-4, YSF-8026, YF100L-4, motor, manufacturer, price
Applicable scope and purpose
BHY series horn type explosion-proof loudspeaker (hereinafter referred to as loudspeaker) is a loudspeaker communication system equipment designed for noisy, flammable and explosive hazardous occasions. It is suitable for inflammable and explosive dangerous places of IIA, IIB, IIC, T1~T6 temperature group (zone 1, zone 2), and can be widely used in petroleum, chemical, pharmaceutical, military, oil depot, dock and other places.
This speaker meets the following standards
GB3836.1-2000 GB3836.2-2000 IEC60079-0 IEC60079-1
Use environmental conditions
a) Altitude: ≤2000 meters;
b) Working environment temperature: -20℃~+40℃
c) The relative humidity of the surrounding air is not more than 95% (+25℃);
d) Where there is no significant shaking and shock vibration;
e) In an environment where there is no gas or vapor that damages the insulation;
f) Pollution level: Level 3;
g) Installation category: Type II.

Date

28 December 2021

Tags

Industrial Axial Flow Fan Electric motor

 Geared Motors And Electric Motor Manufacturer

The best service from our transmission drive expert to your inbox directly.

Get in Touch

Yantai Bonway Manufacturer Co.ltd

ANo.160 Changjiang Road, Yantai, Shandong, China(264006)

T+86 535 6330966

W+86 185 63806647

© 2024 Sogears. All Rights Reserved.