Frame size | ||||||||||||||||||
Code/Variants | 71 | 80 | 90 | 100 | 112 | 132 | 160 | 180 | 200 | 225 | 250 | 280 | 315 | 355 | 400 | 450 | ||
5 | Protective roof | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
72 | Radial seal at D-end. Not possible for 2-pole , 280 and 315 frames | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | |
73 | Sealed against oil at D-end. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
158 | Degree of protection IP65. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
211 | Weather protected, IP xx W | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | - | - | |
250 | Degree of protection IP66 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
401 | Protective roof, horizontal motor. | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
403 | Degree of protection IP56. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
404 | Degree of protection IP56, without fan and fan cover. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | - | - | |
434 | Degree of protection IP56, open deck | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
520 | Motor protection cover made of glass fiber. Vertical motor, shaft | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
down. | ||||||||||||||||||
783 | Labyrinth sealing at D-end. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ○ | ○ | ○ | |
784 | Gamma-seal at D-end. | ● | ● | ● | ● | ● | ● | ○ | ○ | - | ○ | ○ | - | - | - | - | - | |
Rating & instruction plates | ||||||||||||||||||
2 | Restamping voltage, frequency and output, continuous duty. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
4 | Additional text on std rating plate (max 12 digits on free text line). | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
95 | Restamping output (maintained voltage, frequency), intermittent | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
duty. | ||||||||||||||||||
98 | Stainless rating plate | ● | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | - | - | |
126 | Tag plate | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
135 | Mounting of additional identification plate, stainless. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
138 | Mounting of additional identification plate, aluminium. | ● | ● | ● | ● | ● | ● | - | - | - | - | - | - | - | - | - | - | |
139 | Additional identification plate delivered loose. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
159 | Additional plate with text “Made in ....” | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
160 | Additional rating plate affixed. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
161 | Additional rating plate delivered loose. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
163 | Frequency converter rating plate. Rating data according to quota | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
tion. | ||||||||||||||||||
181 | Rating plate with ABB standard loadability values for VSD operation. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Other auxiliaries for VSD operation to be selected as necessary | ||||||||||||||||||
332 | Baldor Catalogue # | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | |
333 | Not for use in the USA | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | |
360 | Cargotec rating plate | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
528 | Rating plate sticker | ● | ● | ● | ● | ● | ● | - | - | - | - | - | ● | ● | ● | ● | ● | |
818 | Restamping as generator | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Shaft & rotor | ||||||||||||||||||
69 | Two shaft extensions according to catalog drawings. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
70 | Special shaft extension at D-End, standard shaft material | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
131 | Motor delivered with half key (key not exceeding shaft diameter) | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | - | - | |
155 | Cylindrical shaft extension, D-end, without key-way. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
164 | Shaft extension with closed keyway | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ● | ● | ● | ● | - | |
165 | Shaft extension with open keyway | - | - | - | - | - | - | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ | |
410 | Shaft material stainless steel | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
591 | Special shaft extension according to customer specification. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
600 | Special shaft extension at N-end, standard shaft material. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
630 | Shaft material certificate 3.1/3.2 according to EN10204:2004 | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Standards and Regulations | ||||||||||||||||||
10 | Fulfilling CSA Safety Certificate. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
208 | Fulfilling Underwriters Laboratories (UL), listed requirements | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
252 | Shell DEP 33.66.05.31-GEN. February 2012, with standard winding >55 | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | - | - | |
kW | ||||||||||||||||||
331 | IE1 motor not for sale for use in EU | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
421 | VIK design (Verband der Industriellen Energie- und Kraftwirtschaft | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | |
e.V.). | ||||||||||||||||||
540 | China energy label | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | |
543 | Australian MEPS | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | |
546 | SABS rating plate | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | |
548 | Certificate of conformity according TR-CU 004/2011 for customs | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
union RU, KZ, BY, AM, KG. | ||||||||||||||||||
822 | WIMES 3.03i6 Compliant Design for DOL operation | ● | ● | ● | ● | ● | ● | - | - | - | - | - | - | - | ● | ● | ● | |
823 | WIMES 3.03i6 Compliant Design for VSD operation | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Stator winding temperature sensors |
○ = Included as standard │ ● = Available as option │ - = Not applicable
Frame size | ||||||||||||||||||
Code/Variants | 71 | 80 | 90 | 100 | 112 | 132 | 160 | 180 | 200 | 225 | 250 | 280 | 315 | 355 | 400 | 450 | ||
120 | KTY 84-130 (1 per phase) in stator winding. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
121 | Bimetal detectors, break type (NCC), (3 in series), 130 ºC, in stator | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
winding | ||||||||||||||||||
122 | Bimetal detectors, break type (NCC), (3 in series), 150 ºC, in stator | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
winding | ||||||||||||||||||
123 | Bimetal detectors, break type (NCC), (3 in series), 170 ºC, in stator | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
winding | ||||||||||||||||||
124 | Bimetal detectors, break type (NCC), (3 in series), 140 ºC, in stator | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
winding | ||||||||||||||||||
125 | Bimetal detectors, break type (NCC), (2x3 in series), 150 ºC, in stator | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
winding | ||||||||||||||||||
127 | Bimetal detectors, break type (NCC), (3 in series, 130 ºC & 3 in series, | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
150 ºC), in stator winding | ||||||||||||||||||
435 | PTC - thermistors (3 in series), 130 ºC, in stator winding | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
437 | PTC - thermistors (3 in series), 170 ºC, in stator winding | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
438 | PTC - thermistors (3 in series), 190 ºC, in stator winding | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
439 | PTC - thermistors (2x3 in series), 150 ºC, in stator winding | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
441 | PTC - thermistors (3 in series, 130 ºC & 3 in series, 150 ºC), in stator | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
winding | ||||||||||||||||||
442 | PTC - thermistors (3 in series, 150 ºC & 3 in series, 170 ºC), in stator | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
winding | ||||||||||||||||||
445 | Pt100 2-wire in stator winding, 1 per phase | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
446 | Pt100 2-wire in stator winding, 2 per phase | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
502 | Pt100 3-wire in stator winding, 1 per phase | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
503 | Pt100 3-wire in stator winding, 2 per phase | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
511 | PTC thermistors (2 x 3 in series), 130 ºC, in stator winding | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
515 | Pt100 3-wire in stator winding, 3 per phase | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
Terminal box | ||||||||||||||||||
15 | Motor supplied in D connection. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | - | - | |
17 | Motor supplied in Y connection | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | - | - | |
19 | Larger than standard terminal box. | ● | ● | ● | ● | ● | ● | - | - | - | - | - | ● | ● | ● | ● | - | |
20 | Detached terminal box | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
21 | Terminal box LHS (seen from D-end). | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | |
22 | Cable entry LHS (seen from D-end). | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
157 | Terminal box degree of protection IP65. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
180 | Terminal box RHS (seen from D-end). | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | |
230 | Standard metal cable gland. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | |
277 | Cable sealing end unit, size small for C-opening | - | - | - | - | - | - | - | - | - | - | - | ● | - | - | - | - | |
278 | Cable sealing end unit, size medium for D-opening | - | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | |
279 | Cable sealing end unit, size large for D-opening | - | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | |
292 | Adapter C-C | - | - | - | - | - | - | - | - | - | - | - | ● | - | - | - | - | |
293 | Adapter D-D | - | - | - | - | - | - | - | - | - | - | - | - | ● | ● | - | - | |
294 | Adapter E-D | - | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | |
295 | Adapter E-2D | - | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ○ | |
296 | Adapter E-3D | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ● | ● | |
351 | Terminal block turned according to cable entry | - | - | - | - | - | - | - | - | - | - | - | ● | ● | - | ● | ● | |
375 | Standard plastic cable gland | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | - | - | |
376 | Two standard plastic cable glands | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | - | - | |
380 | Separate terminal box for temperature detectors, std. material | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
400 | 4 x 90 degr turnable terminal box. | ● | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | - | - | |
413 | Extended cable connection, no terminal box. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
418 | Separate terminal box for auxiliaries, standard material. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
444 | Adapter E-2E | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
447 | Top mounted separate terminal box for monitoring equipment. | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
466 | Terminal box at N-end. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
467 | Lower than standard terminal box and rubber extended cable. Cable | - | - | - | - | - | - | ● | ● | ● | ● | ● | - | - | - | - | - | |
length 2 m | ||||||||||||||||||
468 | Cable entry from D-end. | ● | ● | ● | ● | ● | ● | ● | ● | - | ● | ● | ● | ● | ● | ● | - | |
469 | Cable entry from N-end. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | |
526 | Existing cable entries plugged | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ● | ● | - | - | |
553 | Terminal box degree of protection IP66. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | |
554 | Cast iron flange for cable glands drilled and tapped according to | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
order. | ||||||||||||||||||
557 | Nickel plated cable glands mounted according to order | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
○ = Included as standard │ ● = Available as option │ - = Not applicable
Frame size | ||||||||||||||||||
Code/Variants | 71 | 80 | 90 | 100 | 112 | 132 | 160 | 180 | 200 | 225 | 250 | 280 | 315 | 355 | 400 | 450 | ||
565 | Adapter for terminal box on the side (RHS) | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | - | |
566 | Adapter for terminal box on the side (LHS) | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | - | |
567 | Separate terminal box material: cast Iron | - | - | - | - | - | - | ○ | ○ | ○ | ○ | ○ | ● | ● | ● | ● | ● | |
568 | Separate terminal box for heating elements, std. material | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
569 | Separate terminal box for brakes | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
624 | Prepared for inch cable glands according to BSPP standard. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
727 | Stainless steel flange for cable glands drilled and tapped according | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
to order. | ||||||||||||||||||
730 | Prepared for NPT cable glands. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
731 | Two standard metal cable glands. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
740 | Prepared for PG cable glands. | - | - | - | - | - | - | ● | ● | ● | ● | ● | - | - | - | - | - | |
742 | Protective cover for accessory terminal block in main terminal box | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
743 | Non-drilled cast iron flange for cable glands | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
744 | Stainless steel non-drilled flange for cable glands. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
745 | Painted steel flange equipped with nickel plated brass cable glands | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
746 | Stainless steel cable flange equipped with standard nickel plated | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
brass cable glands | ||||||||||||||||||
Testing | ||||||||||||||||||
140 | Test confirmation. | - | - | - | - | - | - | ● | ● | ● | ● | ● | - | - | - | - | - | |
145 | Type test report from a catalogue motor, 400V 50Hz. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
146 | Type test with report for one motor from specific delivery batch. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
148 | Routine test report. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
149 | Test according to separate test specification. | - | - | - | - | - | - | ● | ● | ● | ● | ● | - | - | - | - | - | |
150 | Customer witnessed testing. Specify test procedure with other | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
codes. | ||||||||||||||||||
222 | Torque/speed test, type test and multi-point load test with report | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
for one motor from specific delivery batch. | ||||||||||||||||||
560 | Shaft voltage test. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
561 | Overspeed test,for one motor from specific delivery batch | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
562 | Overvoltage test. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
760 | Vibration level test | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
761 | Vibration spectrum test for one motor from specific delivery batch. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
762 | Noise level test for one motor from specific delivery batch. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
763 | Noise spectrum test for one motor from specific delivery batch. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
764 | Test for one motor from specific delivery batch with ABB frequency | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
converter available at ABB test field. ABB standard test procedure. | ||||||||||||||||||
Variable speed drives | ||||||||||||||||||
429 | Separate motor cooling (fan top, N-end) and 1024 pulse tacho (Leine | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
& Linde 861) mounted. | ||||||||||||||||||
470 | Prepared for hollow shaft pulse tacho (L&L equivalent). | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
472 | 1024 pulse tacho (L&L 861007455-1024). | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
473 | 2048 pulse tacho (L&L 861007455-2048). | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
474 | Separate motor cooling (axial fan, N-end) and prepared for hollow | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
shaft tacho (L&L equivalent) | ||||||||||||||||||
476 | Separate motor cooling (axial fan, N-end) and 1024 pulse tacho (L&L | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
861007455-1024) | ||||||||||||||||||
477 | Separate motor cooling (axial fan, N-end) and 2048 pulse tacho (L&L | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
861007455-2048) | ||||||||||||||||||
478 | Separate motor cooling (fan on top, N-end) and prepared for hollow | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
shaft tacho (L&L equivalent) | ||||||||||||||||||
479 | Mounting of other type of pulse tacho with shaft extension, tacho | - | - | - | - | - | - | - | ● | ● | - | ● | ● | ● | ● | ● | ● | |
not included. | ||||||||||||||||||
486 | Separate motor cooling (fan top, N-end) and prepared for DC-tacho. | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
510 | Separate motor cooling (fan top, N-end) and 2048 pulse tacho (Leine | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
& Linde 861) mounted. | ||||||||||||||||||
570 | Prepared for hollow shaft pulse tacho (L&L 503). | - | ● | ● | ● | ● | ● | - | - | - | - | - | - | - | - | - | - | |
572 | 1024 pulse tacho (L&L 503). | - | ● | ● | ● | ● | ● | - | - | - | - | - | - | - | - | - | - | |
573 | 2048 pulse tacho (L&L 503). | - | ● | ● | ● | ● | ● | - | - | - | - | - | - | - | - | - | - | |
582 | 1024 pulse tacho, GHK912-GBR-1024, BEI IDEACOD | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
583 | 2048 pulse tacho, GHK912-GBR-2048, BEI IDEACOD | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
588 | Shaft grounding device | - | - | - | - | - | ● | ● | ● | ● | ● | ● | - | - | - | ● | ● | |
658 | Special tacho mounted, price category 1 | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
659 | Special tacho mounted, price category 2 | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
660 | Special tacho mounted, price category 3 | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
680 | 2048 pulse tacho, Ex d, tD, L&L 841910001 | - | - | - | - | - | - | ● | ● | ● | ● | ● | - | - | - | - | - |
○ = Included as standard │ ● = Available as option │ - = Not applicable