      Frame size
Code/Variants     71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
5 Protective roof  
72 Radial seal at D-end. Not possible for 2-pole , 280 and 315 frames   - - -
73 Sealed against oil at D-end.   - - - - - -
158 Degree of protection IP65.  
211 Weather protected, IP xx W   - - - - -
250 Degree of protection IP66  
401 Protective roof, horizontal motor.   - - - - - - - - - - -
403 Degree of protection IP56.  
404 Degree of protection IP56, without fan and fan cover.   - - - - -
434 Degree of protection IP56, open deck   - - - - - - - - - - - -
520 Motor protection cover made of glass fiber. Vertical motor, shaft   - - - - - - - - - - - -
  down.                                  
783 Labyrinth sealing at D-end.   - - - - - -
784 Gamma-seal at D-end.   - - - - - -
Rating & instruction plates                                    
2 Restamping voltage, frequency and output, continuous duty.  
4 Additional text on std rating plate (max 12 digits on free text line).  
95 Restamping output (maintained voltage, frequency), intermittent  
  duty.                                  
98 Stainless rating plate   - -
126 Tag plate  
135 Mounting of additional identification plate, stainless.  
138 Mounting of additional identification plate, aluminium.   - - - - - - - - - -
139 Additional identification plate delivered loose.  
159 Additional plate with text “Made in ....”  
160 Additional rating plate affixed.  
161 Additional rating plate delivered loose.  
163 Frequency converter rating plate. Rating data according to quota   
  tion.                                  
181 Rating plate with ABB standard loadability values for VSD operation.  
  Other auxiliaries for VSD operation to be selected as necessary                                  
332 Baldor Catalogue #   - -
333 Not for use in the USA   - -
360 Cargotec rating plate   - - - - - -
528 Rating plate sticker   - - - - -
818 Restamping as generator   - - - - - -
Shaft & rotor                                    
69 Two shaft extensions according to catalog drawings.  
70 Special shaft extension at D-End, standard shaft material  
131 Motor delivered with half key (key not exceeding shaft diameter)   - - - - -
155 Cylindrical shaft extension, D-end, without key-way.  
164 Shaft extension with closed keyway   -
165 Shaft extension with open keyway   - - - - - -
410 Shaft material stainless steel  
591 Special shaft extension according to customer specification.  
600 Special shaft extension at N-end, standard shaft material.  
630 Shaft material certificate 3.1/3.2 according to EN10204:2004   - - - - - -
Standards and Regulations                                    
10 Fulfilling CSA Safety Certificate.   - - - - - -
208 Fulfilling Underwriters Laboratories (UL), listed requirements  
252 Shell DEP 33.66.05.31-GEN. February 2012, with standard winding >55   - - - - - - - - - - - - -
  kW                                  
331 IE1 motor not for sale for use in EU  
421 VIK design (Verband der Industriellen Energie- und Kraftwirtschaft   -
  e.V.).                                  
540 China energy label   - -
543 Australian MEPS   - - -
546 SABS rating plate   -
548 Certificate of conformity according TR-CU 004/2011 for customs  
  union RU, KZ, BY, AM, KG.                                  
822 WIMES 3.03i6 Compliant Design for DOL operation   - - - - - - -
823 WIMES 3.03i6 Compliant Design for VSD operation  
Stator winding temperature sensors                                    

 ○ = Included as standard │ ● = Available as option │ - = Not applicable

 

      Frame size
Code/Variants     71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
120 KTY 84-130 (1 per phase) in stator winding.   - - - - - -
121 Bimetal detectors, break type (NCC), (3 in series), 130 ºC, in stator  
  winding                                  
122 Bimetal detectors, break type (NCC), (3 in series), 150 ºC, in stator  
  winding                                  
123 Bimetal detectors, break type (NCC), (3 in series), 170 ºC, in stator  
  winding                                  
124 Bimetal detectors, break type (NCC), (3 in series), 140 ºC, in stator   - - - - - -
  winding                                  
125 Bimetal detectors, break type (NCC), (2x3 in series), 150 ºC, in stator   - - - - - -
  winding                                  
127 Bimetal detectors, break type (NCC), (3 in series, 130 ºC & 3 in series,  
  150 ºC), in stator winding                                  
435 PTC - thermistors (3 in series), 130 ºC, in stator winding  
437 PTC - thermistors (3 in series), 170 ºC, in stator winding  
438 PTC - thermistors (3 in series), 190 ºC, in stator winding   - - - - - - - - - - -
439 PTC - thermistors (2x3 in series), 150 ºC, in stator winding  
441 PTC - thermistors (3 in series, 130 ºC & 3 in series, 150 ºC), in stator  
  winding                                  
442 PTC - thermistors (3 in series, 150 ºC & 3 in series, 170 ºC), in stator  
  winding                                  
445 Pt100 2-wire in stator winding, 1 per phase  
446 Pt100 2-wire in stator winding, 2 per phase   - - - - - -
502 Pt100 3-wire in stator winding, 1 per phase   - - - - - -
503 Pt100 3-wire in stator winding, 2 per phase   - - - - - -
511 PTC thermistors (2 x 3 in series), 130 ºC, in stator winding   - - - - - -
515 Pt100 3-wire in stator winding, 3 per phase   - - - - - - - - - - -
Terminal box                                    
15 Motor supplied in D connection.   - - - - -
17 Motor supplied in Y connection   - - - - -
19 Larger than standard terminal box.   - - - - - -
20 Detached terminal box   - - - - - - - - - - -
21 Terminal box LHS (seen from D-end).   -
22 Cable entry LHS (seen from D-end).  
157 Terminal box degree of protection IP65.   - - - - - -
180 Terminal box RHS (seen from D-end).   -
230 Standard metal cable gland.   - -
277 Cable sealing end unit, size small for C-opening   - - - - - - - - - - - - - - -
278 Cable sealing end unit, size medium for D-opening   - - - - - - - - - - - -
279 Cable sealing end unit, size large for D-opening   - - - - - - - - - - - -
292 Adapter C-C   - - - - - - - - - - - - - - -
293 Adapter D-D   - - - - - - - - - - - - - -
294 Adapter E-D   - - - - - - - - - - - -
295 Adapter E-2D   - - - - - - - - - - - -
296 Adapter E-3D   - - - - - - - - - - - - - -
351 Terminal block turned according to cable entry   - - - - - - - - - - - -
375 Standard plastic cable gland   - - - - -
376 Two standard plastic cable glands   - - - - -
380 Separate terminal box for temperature detectors, std. material   - - - - - -
400 4 x 90 degr turnable terminal box.   - -
413 Extended cable connection, no terminal box.   - - - - - -
418 Separate terminal box for auxiliaries, standard material.  
444 Adapter E-2E   - - - - - -
447 Top mounted separate terminal box for monitoring equipment.   - - - - - - - - - - -
466 Terminal box at N-end.   - - - - - -
467 Lower than standard terminal box and rubber extended cable. Cable   - - - - - - - - - - -
  length 2 m                                  
468 Cable entry from D-end.   - -
469 Cable entry from N-end.   -
526 Existing cable entries plugged   - -
553 Terminal box degree of protection IP66.   -
554 Cast iron flange for cable glands drilled and tapped according to   - - - - - -
  order.                                  
557 Nickel plated cable glands mounted according to order   -

 ○ = Included as standard │ ● = Available as option │ - = Not applicable

 

      Frame size
Code/Variants     71 80 90 100 112 132 160 180 200 225 250 280 315 355 400 450
565 Adapter for terminal box on the side (RHS)   - - - - - - - - - -
566 Adapter for terminal box on the side (LHS)   - - - - - - - - - -
567 Separate terminal box material: cast Iron   - - - - - -
568 Separate terminal box for heating elements, std. material   - - - - - -
569 Separate terminal box for brakes   - - - - - -
624 Prepared for inch cable glands according to BSPP standard.  
727 Stainless steel flange for cable glands drilled and tapped according   - - - - - -
  to order.                                  
730 Prepared for NPT cable glands.  
731 Two standard metal cable glands.  
740 Prepared for PG cable glands.   - - - - - - - - - - -
742 Protective cover for accessory terminal block in main terminal box   - - - - - - - - - - -
743 Non-drilled cast iron flange for cable glands   - - - - - -
744 Stainless steel non-drilled flange for cable glands.   - - - - - -
745 Painted steel flange equipped with nickel plated brass cable glands   - - - - - -
746 Stainless steel cable flange equipped with standard nickel plated   - - - - - -
  brass cable glands                                  
Testing                                    
140 Test confirmation.   - - - - - - - - - - -
145 Type test report from a catalogue motor, 400V 50Hz.  
146 Type test with report for one motor from specific delivery batch.  
148 Routine test report.  
149 Test according to separate test specification.   - - - - - - - - - - -
150 Customer witnessed testing. Specify test procedure with other  
  codes.                                  
222 Torque/speed test, type test and multi-point load test with report  
  for one motor from specific delivery batch.                                  
560 Shaft voltage test.  
561 Overspeed test,for one motor from specific delivery batch  
562 Overvoltage test.  
760 Vibration level test  
761 Vibration spectrum test for one motor from specific delivery batch.   - - - - - -
762 Noise level test for one motor from specific delivery batch.  
763 Noise spectrum test for one motor from specific delivery batch.   - - - - - -
764 Test for one motor from specific delivery batch with ABB frequency   - - - - - -
  converter available at ABB test field. ABB standard test procedure.                                  
Variable speed drives                                    
429 Separate motor cooling (fan top, N-end) and 1024 pulse tacho (Leine   - - - - - - - - - - -
  & Linde 861) mounted.                                  
470 Prepared for hollow shaft pulse tacho (L&L equivalent).   - - - - - -
472 1024 pulse tacho (L&L 861007455-1024).   - - - -
473 2048 pulse tacho (L&L 861007455-2048).   - - - -
474 Separate motor cooling (axial fan, N-end) and prepared for hollow   - - - - - -
  shaft tacho (L&L equivalent)                                  
476 Separate motor cooling (axial fan, N-end) and 1024 pulse tacho (L&L   - - - - - -
  861007455-1024)                                  
477 Separate motor cooling (axial fan, N-end) and 2048 pulse tacho (L&L   - - - - - -
  861007455-2048)                                  
478 Separate motor cooling (fan on top, N-end) and prepared for hollow   - - - - - - - - - - -
  shaft tacho (L&L equivalent)                                  
479 Mounting of other type of pulse tacho with shaft extension, tacho   - - - - - - - -
  not included.                                  
486 Separate motor cooling (fan top, N-end) and prepared for DC-tacho.   - - - - - - - - - - -
510 Separate motor cooling (fan top, N-end) and 2048 pulse tacho (Leine   - - - - - - - - - - -
  & Linde 861) mounted.                                  
570 Prepared for hollow shaft pulse tacho (L&L 503).   - - - - - - - - - - -
572 1024 pulse tacho (L&L 503).   - - - - - - - - - - -
573 2048 pulse tacho (L&L 503).   - - - - - - - - - - -
582 1024 pulse tacho, GHK912-GBR-1024, BEI IDEACOD   - - - - - - - - - - -
583 2048 pulse tacho, GHK912-GBR-2048, BEI IDEACOD   - - - - - - - - - - -
588 Shaft grounding device   - - - - - - - -
658 Special tacho mounted, price category 1   - - - - - -
659 Special tacho mounted, price category 2   - - - - - -
660 Special tacho mounted, price category 3   - - - - - -
680 2048 pulse tacho, Ex d, tD, L&L 841910001   - - - - - - - - - - -

 ○ = Included as standard │ ● = Available as option │ - = Not applicable

 

 

 

 

 

 