This research is purposed to establish a simple method for operating the three phase induction motors of delta connection standard with single-phase power by using capacitor circuit to the motor. The research was conducted at the Laboratory of the Electrical Engineering of Institut Teknologi Padang. The object used in this research was the 3-phase induction motor of 1.5 HP, 380/220V, Y/, 2.75/4.74A, 4 poles, 50 Hz, 1400 RPM. The results showed that the motor could work well on single phase power load by up to 66% of the 3-phase rating. The motor could operated on power factor close to unity, with lower current harmonic distortion and efficiency.

A comparative study of equal, triangular, stepped, sinusoidal, and inverted sinusoidal pulse-width modulation (PWM) schemes on source and load performances of a three-phase AC-DC GTO thyristor converter-fed DC motor is presented. The two-quadrant GTO thyristor converter is studied in detail using an equal PWM (EPWM) scheme. A symmetrical gate pulse pattern that reduces the number of switchings and allows switching GTOs an equal number of times in each supply cycle is reported. Smooth and continuous transition is obtained between rectification and inversion with a single GTO converter. The proposed converter was designed, constructed, and tested using a 3 hp laboratory-sized separately excited DC motor. The experimental results are shown to be in good agreement with the theory.

Scheda was a person who published a method for operating the 3-phase induction motor on singlephase supply in 1985. The method installs a capacitor circuit on the terminal of the motor. So the motor operated like a single phase induction motor. This method only creates some formulas for calculating the capacitor that suitable for operating the 3-phase induction motor on single phase supply. The formulas could not be used for predicting characteristics of the motor in variation speed conditions. Therefore, this research is proposed to create a steady-state equivalent circuit includes its formulas for analyzing the motor on varying speed conditions, especially for power output and efficiency of the motor. The 3-phase induction motor used in this research was the motor of 1.5 HP, 380/220V, Y/, 2.75/4.7A, 4 poles, 50Hz, 1400 RPM. For validating the formulas, the motor also tested in a laboratory. The results showed that the formulas and equivalent circuit was given had good accuracy when they compared with the results of experiments in the laboratory.

Delta Connection Standard of the 3hp motor single phase on Single Phase Supply

A single phase induction motor having a main field winding and an auxiliary field winding provided with a phase advancing capacitor is controlled by a control unit having a timer unit and a by-pass switch for by passing the phase advancing capacitor. The main field winding is provided with a main switch operable by a relay controlled by the timer. The control unit also has a clutch detecting unit which detects the engagement and disengagement of the clutch adapted to couple the motor with a load such as a sewing machine. The timer is so set to activate the relay after a predetermined time period when the clutch is disengaged to relieve the motor of its load, whereby the relay causes the main switch to open, and the by-pass switch to close, such that the motor is operated solely on the auxiliary field winding when no load is applied, so as to save the power consumption at an idling operation.

Presently, various multimedia devices such as MP3 player, camera and even TV are integrated into mobile phones. Consumer demands cameras in mobile phones to have similar image quality and performance as those of digital cameras since pixel size of image sensor in cameras are increasing continuously more than 5 mega pixel. This increase of pixel size in phone cameras require at least one basic function that is optical auto focusing that a small lens group need to be moved about half of a millimeter. Piezoelectric motors are suitable for lens positioning mechanism in phone cameras because their sizes are highly scalability and their efficiencies are insensitive to size. Therefore it is possible to obtain high performance from a miniaturized piezoelectric motor. The motor presented in this study is specifically design for lens moving mechanism in a phone camera for auto focusing (AF) function. The motor is single phase-mixed-mode excitation type that second bending mode is superimposed into second dilatational mode to generate a circular motion.

When it comes to Three phase equipment to be used phase motors or pumps and other forming equipment. Inwith one of the three phase failed, what one requires is a systemwhich will convert the available one and lor two phase supply into equivalent nearly balanced three phase supply. This study isone of the solutions to design such system. The heart of thissystem is nothing but the 'SCOTT CONNECTION'. Here thereare two individual single phase transformers, designed &connected in such a fashion that the output will be balanced therephase supply of equal voltage phase difference. Also it electric traction application, only a single phase supply is available inside the train. Static phase converters using controlled power semiconductor device have now become common due to lower cost, size and better performance of the overall system, consisting of motor and converter. Using semiconductor converter for conversion from single phase to three phaseincorporates the control unit i.e. required to switch over to voltage can help in saving energy in two ways.

In many rural areas where only single-phase power is available from the local utility, operation of induction motors that drive large loads can be a problem. For loads up to about 20 hp, single-phase induction motors can be used with easily. For larger loads, the single-phase induction motors required a specific designed starting windings and control circuits. Such induction motors are often considerably higher in cost than the equivalent 3-phase induction motors.

Delta Connection Standard of the 3hp motor single phase on Single Phase Supply

We study radiative and nonradiative recombination at individual dislocations in GaN by cathodoluminescence performed in a transmission electron microscope. The dislocations are produced by indentation of dislocation free single crystals and havea-type Burgers vectors.They are aligned along directions in the basal plane. Our direct correlation between structural and optical properties on a microscopic scale yields two main results: (i) 60°-basal plane dislocations show radiative recombination at 2.9 eV; (ii) screw-type basal plane dislocations act as nonradiative recombination centers. We explain the nonradiative recombination by splitting this dislocation into 30° partials that have dangling bonds in the core. The dissociation width of these dislocations is <2 nm.

PIC microcontroller based PWM inverter controlled four switch three phase inverter (FSTPI) fed Induction Motor drive. The advantage of . Three-phase induction motor: 3 hp, 400 V, 50 Hz, 1500 rpm. The 3-phase . bit microcontroller (MCU) architecture. half bridge inverter and triac is applied to the three phase . Single phase 230V,50Hz AC supply is applied to the. Microcontroller Based Inverter. The technology is a microcontroller based sine waveinverter wherein the main power is directly sent to the output and the AC is implementation of a microcontroller based3-phase PFM generation scheme is lower than that of a square wave inverter, as in the case of sinusoidal PWM.

A three phase induction motor drive using IGBTs at the inverter power stage with volts hertz control (V/F) in closed loop using dsPIC30F5011 as a controller. It is a 16 bit high performance digital signal controller (DSC). DSC is a single chip embedded controller that integrates the controller attributes of a microcontroller with the computation and throughput capabilities of a DSP in a single core. A 1.5HP, 3-phase, 415V, 50Hz induction motor is used as load for the inverter. Digital Storage Oscilloscope Textronix TDS2024B is used to record and analyze the various waveforms. The experimental results for V/F control of 3- Phase induction motor using dsPIC30F5011 chip clearly shows constant volts per hertz and stable inverter line to line output voltage.

Sillimanite is chemically named Aluminum Silicate (Al2SiO5) which is rare and one of the Trimorphs of alumino silicate polymorphs. Sillimanite is an important mineral among the mineral sand deposits and predominantly occurs along the costal line of India. The Sillimanite mineral occurs in beach and dune placer deposits along with strategic and economically important heavy minerals heavy minerals such as ilmenite, rutile, zircon, garnet and monazite. Trimex Sands Pvt Limited (TSPL), a mineral wing of Trimex Group is operating a heavy mineral sands mine based on Srikurmam Deposit in the district of Srikakulam in the state of Andhra Pradesh. At TSPL, froth flotation is employed to separate Sillimanite from quartz and the performance of the flotation circuit is not at par with that of the design. Earlier studies were successfully conducted to optimize the parameters to improve the performance of the flotation circuit using design of experimentation and ANOVA. This paper deals with various efforts made to enhance the performance of the sillimanite flotation further.

The separation of variants of chromosomal proteins exhibiting closely related amino acid compositions has been achieved using weak cation-exchange or reversed-phase high-performance liquid chromatography. The purity of the isolated proteins has been ascertained by polyacrylamide gel electrophoresis and in several cases by micro-sequencing.

Delta Connection Standard of the 3hp motor single phase on Single Phase Supply

Small rated self-excited induction generators (SEIG) are most suitable for Pico hydro power generation systems in remote mountainous regions for feeding three-phase and single-phase domestic load using 3-phase 4-wire system. The voltage and frequency control is a big challenge in ever changing domestic load scenario. The electronic load controller (ELC) is examined experimentally in this paper. To mitigate harmonics in the standalone SEIG system with the increasing use of electronic gadgets with non-linear load, compact fluorescent lamps, light emitting diodes and computers etc., use of various transformer configurations is evaluated. This paper also presents the experimental evaluation of star-delta and zigzag transformer configurations for harmonic mitigation in 3-phase SEIG system while emulating actual load of isolated mountainous regions in India. The experimental set-up uses a 3HP, 3-phase, 4-pole induction machine coupled with a similar rating DC shunt motor, a multipurpose 3-phase transformer setup for emulation of different configurations.

Motors are widely used in industries due to its ability to provide high mechanical power in speed and torque applications. Its flexibility to control and quick response are other reasons for its widespread use. Disturbance torque acting on the motor shaft is a major factor which affects the motor performance. Considering the load disturbance torque while designing the control for the motor makes the system more robust to load changes. Most disturbance observers are designed for steady state load conditions. The observer designed here considers a general case making no assumptions about the load torque dynamics. The observer design methods to be used under different disturbance conditions are also discussed and the performances compared.

An electronic component formed as a regulator for generators in motor vehicles has an IC block arranged on a cooling body, connectors provided with conductors, connectors provided with conductors, bond wire connectors connecting the IC block with the conductors, the conductors being provided at first ends which face the IC block with a first bond pad, means forming a limited free space behind the first bond pad as seen from the IC block for insertion and withdrawal of a bond tool, the conductors of the plug connectors being each provided with a further bond pad located behind the limited free space at a distance from the first bond pad, for further bond wire connections of at least one selectively useable electronic component.

A compact, high-torque electric motor in which one motor element (either the stator or rotor) has magnetic poles whose effective magnetic width is substantially equal and which span equal center angles. The second motor element has a plurality of armature groups, each of which occupies a phase sector of the motor element formed by dividing the total periphery by a natural number. All of the armatures within an armature group are connected electrically in series and excited with a current of one phase (either an alternating current phase or an equivalent phase generated by commutator action). Within on pole group the poles may have equal widths or different widths.

Delta Connection Standard of the 3hp motor single phase on Single Phase Supply

In a resonant motor system, an electrical motor having a stator with one or more windings, a rotor which may or may not be wound, and an air gap between the stator and the rotor for storing magnetic energy such that the motor exhibits a definite electrical inductance may be deployed with a drive combination including a capacitance connected in series with the inductance of the motor to form an LCR circuit therewith. Phased provision of DC power to the LCR circuit causes the circuit to oscillate, which excites the motor. The DC power is provided in synchronism with the rotation of the rotor in order to maximize torque produced by the motor.

A system and method for determining stator winding resistance in an AC motor is disclosed. The system includes a circuit having an input connectable to an AC source and an output connectable to an input terminal of an AC motor. The circuit includes at least one contactor and at least one switch to control current flow and terminal voltages in the AC motor. The system also includes a controller connected to the circuit and configured to modify a switching time of the at least one switch to create a DC component in an output of the system corresponding to an input to the AC motor and determine a stator winding resistance of the AC motor based on the injected DC component of the voltage and current.

A method for estimating resistance of a DC motor for positioning read/write heads of a data storage disk is provided. The DC motor is controlled in an open-loop voltage mode through a motor controller input with a first signal for compensating positioning of the read/write heads onto the data storage disk. The first signal is generated based upon a position error signal representing a difference between a position of the read/write heads and a center of a track to be read. The method includes monitoring the first signal during a read operation of data being stored on the data storage disk, and estimating the resistance based upon spectral components of the first signal.

This research is purposed to establish a new method is good and simple to operate the 3-phase induction motor on single-phase power by using the capacitors. The research was conducted at the Laboratory of the Electrical Engineering of the Padang Institute of Technology. The object used in this research was the 3-phase induction motor that has the standard of 2 HP,380 V, Wye connection, 4 pole, 50 Hz, 1400 RPM, 3.6 A. The results of this research showed that the method could work well to control the motor to operate properly to load 85% of the 3-phase rating. In general, the motor has a better performance when operating on 1-phase power system in all load cases (low and high load). The motor could operate with power factor close to unity, higher speed and better efficiency. The motor operated with higher current harmonic distortion at low loads but lower current harmonic distortion at high loads. Therefore, it is very good to operate the motor at high load up to 85% of the 3-phase rating.

Delta Connection Standard of the 3hp motor single phase on Single Phase Supply

The fundamental-frequency components from the voltage and current waveforms in a Split-Phase induction motors that is fed through a Static Voltage Controller. These components are derived not from conducting a Fast Fourier Transform, but rather from few phase angles that are easily provided by zero-crossing and peak detectors. It is shown that knowledge of these components is useful when attempting to optimize load efficiency, and when assessing the power loss due to harmonic distortion. The analysis in this paper is partially validated by laboratory tests on a 1/3 hp split-phase motor.

Embodiments of the invention provide a variable frequency drive system and a method of controlling a pump driven by a motor with the pump in fluid communication with a fluid system. The drive system and method can provide one or more of the following: a sleep mode, pipe break detection, a line fill mode, an automatic start mode, dry run protection, an electromagnetic interference filter compatible with a ground fault circuit interrupter, two-wire and three-wire and three-phase motor compatibility, a simple start-up process, automatic password protection, a pump out mode, digital input/output terminals, and removable input and output power terminal blocks.