Variant codes
Cast iron motors
Variant codes specify additional options and features to the standard motor. The desired features are listed as three-digit variant codes in the motor order. Note also that there are variants that cannot be used together.
Most of the variant codes apply to IE2, IE3, and IE4 motors. However, confirm the availability of variants for IE3 and IE4 motors with your ABB sales office before making an order.
Frame size | ||||||||||||||||||
Code/Variants | 71 | 80 | 90 | 100 | 112 | 132 | 160 | 180 | 200 | 225 | 250 | 280 | 315 | 355 | 400 | 450 | ||
Administration | ||||||||||||||||||
529 | Customer witnessed visual inspection of complete order line. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
530 | Two-year extension on standard warranty | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
531 | Sea freight packing | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
533 | Wooden sea freight packing | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
590 | Mounting of customer supplied part other than coupling | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | |
683 | Prepared for ABB Ability Smart Sensor | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
684 | ABB Ability Smart sensor mounted | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Balancing | ||||||||||||||||||
417 | Vibration acc. to Grade B (IEC 60034-14) | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
423 | Balanced without key. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
424 | Full-key balancing | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Bearings and Lubrication | ||||||||||||||||||
036 | Transport lock for bearings. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
037 | Roller bearing at D-end. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
39 | Cold-resistant grease | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
40 | Heat-resistant grease | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
41 | Bearings regreasable via grease nipples. | ● | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | |
43 | SPM compatible nipples for vibration measurement | ● | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | |
57 | 2RS bearings at both ends. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | - | - | |
58 | Angular contact bearing at D-end, shaft force away from bearing. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
59 | Angular contact bearing at N-end, shaft force towards bearing. | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | |
60 | Angular contact bearing at D-end, shaft force towards bearing. | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | |
61 | Angular contact bearing at N-end, shaft force away from bearing. | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | |
107 | Pt100 2-wire in bearings. | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
128 | Double PT100, 2-wire in bearings | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
129 | Double PT100, 3-wire in bearings | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
130 | Pt100 3-wire in bearings. | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
188 | 63-series bearing in D-end | ● | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | |
194 | 2Z bearings greased for life at both ends | ○ | ○ | ○ | ○ | ○ | ○ | ● | ● | ● | ● | ● | - | - | - | - | - | |
420 | Bearing mounted PTC thermistors | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
433 | Outlet grease collector | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
506 | Nipples for vibration measurement : SKF Marlin Quick Connect stud CMSS-2600-3 |
- | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
593 | Bearings grease suitable for food and beverage industry. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
654 | Provision for vibration sensors (M8x1) | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
795 | Lubrication information plate | - | - | - | - | - | - | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ | |
796 | Grease nipples JIS B 1575 PT 1/8 Type A | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
797 | Stainless steel SPM nipples | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
798 | Stainless steel grease nipples | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
799 | Grease nipples flat type DIN 3404, thread M10x1 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
800 | Grease nipples JIS B 1575 PT 1/8” pin type | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Brakes | ||||||||||||||||||
517 | KFB holding brake | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | - | - | |
518 | SFB-SH holding brake | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
Branch standard designs | ||||||||||||||||||
142 | Manilla connection. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - |
○ = Included as standard │ ● = Available as option │ - = Not applicable
Frame size | ||||||||||||||||||
Code/Variants | 71 | 80 | 90 | 100 | 112 | 132 | 160 | 180 | 200 | 225 | 250 | 280 | 315 | 355 | 400 | 450 | ||
172 | Smoke venting specification, 300 ºC, 1 hour, DOL use, class F300 ac cording to EN 12101-3 |
- | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
173 | Smoke venting specification, 200 ºC, 2 hours, DOL use, class F200 according to EN 12101-3 |
- | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
174 | Smoke venting specification, 400 ºC, 2 hours, DOL use, class F400 according to EN 12101-3 |
- | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
177 | Design for high ambient applications | - | - | - | - | - | - | ● | ● | ● | ● | ● | - | - | - | - | - | |
178 | Stainless steel / acid proof bolts. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
204 | Jacking bolts for foot mounted motors | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ○ | ○ | ○ | |
209 | Non-standard voltage or frequency, (special winding). | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
386 | Smoke venting specification, 200 ºC, 2 hours, VSD use, Class F200 according to EN 12101-3. |
- | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
387 | Smoke venting specification, 300 ºC, 1 hour, VSD use, Class F300 ac cording to EN 12101-3 |
- | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
389 | Smoke Venting specification, 400 ºC, 2 hours, VSD use, Class F400 according to EN 12101-3 |
- | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
392 | Smoke Venting specification, 250 ºC, 2 hours, DOL use, Class T250 | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
393 | Smoke venting specification, 250 ºC, 2 hours, VSD use, Class T250 | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | - | |
396 | Motor designed for minimum ambient temperature -20 °C to -40 °C, with space heaters (code 450/451 must be added) |
● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
397 | Motor designed for minimum ambient temperature -40 °C to -55 °C, with space heaters (code 450/451 must be added) |
- | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
398 | Motor designed for minimum ambient temperature -20 °C to -40 °C | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
399 | Motor designed for minimum ambient temperature -40 °C to -55 °C | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
425 | Corrosion protected stator and rotor core. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
524 | Special run-out tolerances on flange and shaft for close coupled pump applications. |
- | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | - | - | |
625 | Design for mining applications | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | |
786 | Special design shaft upwards (V3, V36, V6) for outdoor mounting. | - | - | - | - | - | - | ● | ● | - | ● | ● | - | - | - | - | - | |
877 | Design for high ambient applications, motor without fan and fan cover |
- | - | - | - | - | - | ● | ● | ● | ● | ● | - | - | - | - | - | |
Cooling system | ||||||||||||||||||
44 | Unidirectional fan for reduced noise level. Rotation clockwise seen from D-end. Available only for 2-pole motors. |
- | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
45 | Unidirectional fan for reduced noise level. Rotation counter clockwise seen from D-end. Available only for 2-pole motors. |
- | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
68 | Light alloy metal fan | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
75 | Cooling method IC418 (without fan). | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
183 | Separate motor cooling (fan axial, N-end). | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
206 | Steel fan | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
422 | Separate motor cooling (on top) with integrated fan motor | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
514 | Separate motor cooling (fan on top) | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
791 | Stainless steel fan cover | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | |
Coupling | ||||||||||||||||||
35 | Assembly of customer supplied coupling-half | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
Documentation | ||||||||||||||||||
141 | Binding 2D main dimension drawing. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
370 | Motor model drawing in 3D | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
374 | Binding 2D motor detailed drawing | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
536 | Photos of manufactured motors | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
537 | Advanced data sheet | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
722 | Rotor dimension drawing (incl. torosional stiffness) | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
777 | Premium documentation package | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Drain holes | ||||||||||||||||||
65 | Plugged existing drain holes. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
448 | Draining holes with metal plugs. | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
Earthing Bolt | ||||||||||||||||||
67 | External earthing bolt | ● | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | |
525 | External earthing bolts on motor feet | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Hazardous Environments | ||||||||||||||||||
456 | Ex ec IIC T3 Gc acc. IEC/EN 60079-7 with certificates. | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | - | - | |
Heating elements | ||||||||||||||||||
450 | Heating element, 100-120 V | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
451 | Heating element, 200 - 240 V | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
○ = Included as standard │ ● = Available as option │ - = Not applicable
Frame size | ||||||||||||||||||
Code/Variants | 71 | 80 | 90 | 100 | 112 | 132 | 160 | 180 | 200 | 225 | 250 | 280 | 315 | 355 | 400 | 450 | ||
14 | Winding insulation class H. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
405 | Special winding insulation for frequency converter supply | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
406 | Winding insulation for supply > 690 <= 1000 volts | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | |
Marine | ||||||||||||||||||
24 | Fulfilling Bureau Veritas (BV) requirements, with certificate. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
25 | Fulfilling Det Norske Veritas (DNV) requirements, with certificate. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
26 | Fulfilling Lloyds Register of Shipping (LR) requirements, with certifi | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
cate. | ||||||||||||||||||
27 | Fulfilling American Bureau of Shipping (ABS) requirements, with | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
certificate. | ||||||||||||||||||
49 | Fulfilling Germanischer Lloyd (GL) requirements, with certificate. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
50 | Fulfilling Registro Italiano Navale (RINA) requirements, with certifi | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
cate. | ||||||||||||||||||
51 | Fulfilling Russian Maritime Register of Shipping (RS) requirements, | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
with certificate. | ||||||||||||||||||
96 | Fulfilling Lloyds Register of Shipping (LR) requirements, without | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
certificate (non-essential duty only) | ||||||||||||||||||
186 | Fulfilling Det Norske Veritas (DNV) requirements, without certificate | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
481 | Fulfilling Nippon Kaiji Kyokai (NK) requirements, with certificate | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
483 | Fulfilling China Classification Societies (CCS) requirements (Beijing), | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
with certificate. | ||||||||||||||||||
484 | Fulfilling Korea Register of Shipping (KR) requirements, with certifi | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
cate. | ||||||||||||||||||
491 | Fulfilling Nippon Kaiji Kyokai (NK) requirements, without certificate. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
492 | Fulfilling Registro Italiano Navale (RINA) requirements, without | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
certificate. | ||||||||||||||||||
493 | Fulfilling China Classification Societies (CCS) requirements (Beijing), | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
without certificate. | ||||||||||||||||||
494 | Fulfilling Korea Register of Shipping (KR) requirements, without | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
certificate | ||||||||||||||||||
496 | Fulfilling Bureau Veritas (BV) requirements, without certificate(non | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
essential duty only) | ||||||||||||||||||
497 | Fulfilling Russian Maritime Register of Shipping (RS) requirements, | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
without certificate. | ||||||||||||||||||
675 | Fulfilling American Bureau of Shipping (ABS) requirements, without | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
certificate (non-essential duty only) | ||||||||||||||||||
676 | Fulfilling Germanischer Lloyd (GL) requirements, without certificate | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
(non-essential duty only) | ||||||||||||||||||
Mounting arrangements | ||||||||||||||||||
8 | IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from | ● | ● | ● | ● | ● | ● | - | - | - | - | - | - | - | - | - | - | |
B3). | ||||||||||||||||||
9 | IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
B3). | ||||||||||||||||||
47 | IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). | ● | ● | ● | ● | ● | ● | - | - | - | - | - | - | - | - | - | - | |
64 | NEMA D-flange | - | - | - | - | - | - | - | - | - | - | - | - | - | ● | - | - | |
66 | Modified for specified mounting position differing from IM B3 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
(1001), IM B5 (3001), B14 (3601), IM B35 (2001), IM B34 (2101) | ||||||||||||||||||
305 | Additional lifting lugs. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
320 | IM2001 foot/flat bottom flange mounted, from IM1001 (B35 flat bot | ● | ● | ● | ● | ● | ● | - | - | - | - | - | - | - | - | - | - | |
tom flange from B3) | ||||||||||||||||||
Noise reduction | ||||||||||||||||||
55 | Noise reduction cover for foot mounted motor | - | - | - | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
Painting | ||||||||||||||||||
105 | Paint thickness report | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
114 | Special paint color, standard grade | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
115 | Painting system C4M acc. to ISO 12944-2: 1998 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
168 | Primer paint only. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
303 | Painted insulation layer on inside of the terminal boxes. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
710 | Thermally sprayed zink metallizing with acrylic top coat | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
711 | Painting system C5-M very high, acc. to ISO 12944-5:2007 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
712 | Painting system C5-M according to Petrobras specification. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
713 | Painting system according Total Egina specification. | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
754 | Painting system C5M acc. to ISO 12944-2:1998 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
755 | Norsok M-501 revision 6, Coating system no. 1 | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
Protection |
○ = Included as standard │ ● = Available as option │ - = Not applicable