3 phase squirrel cage induction motor
We produce AC DC MOTOR at shanghai china .
Power: 50kw-500kw-1000kw-1500kw-5000kw-1500kw
Voltage: 220V/380V/6.6KV/10KV,20KV....
3 phase squirrel cage induction motor from 0.15kw, 0.5kw,0.75kw, 1kw ,2 kw ......10kw ...
YR Series HV Wound Rotor Motor (Slip Ring Motor)
Power: | 220kw - 3150KW |
Voltage: | 3KV, 6KV, 10KV |
Speed: | 500RPM/590RPM/740RPM/990RPM/1500RPM/3000RPM |
Protection Degree: | IP44/IP54 |
Cooling method: | ICW81A |
Insulation Class: | F |
Duty: | S1 |
Package: | Export Wooden Package |
Payment: | 30% in advance, balance by T/T or L/C at sight |
YR5001-6, 450KW, 10000V, 990r/min, IC01, IP23, F Insulation
YR5002-6, 500KW, 10000V, 990r/min, IC01, IP23, F Insulation
YR5003-6, 560KW, 10000V, 990r/min, IC01, IP23, F Insulation
YR5004-6, 630KW, 10000V, 985r/min, IC01, IP23, F Insulation
YR5005-6, 710KW, 10000V, 990r/min, IC01, IP23, F Insulation
YRKS Series HV Wound Rotor Motor (Slip Ring Motor)
Power: | 220kw - 3150KW |
Voltage: | 3KV, 6KV, 10KV |
Speed: | 500RPM/590RPM/740RPM/990RPM/1500RPM/3000RPM |
Protection Degree: | IP44/IP54 |
Cooling method: | ICW81A |
Insulation Class: | F |
Duty: | S1 |
Package: | Export Wooden Package |
Payment: | 30% in advance, balance by T/T or L/C at sight |
YRKS5001-6, 450KW, 10000V, 990r/min, ICW81A, IP44/IP54, F Insulation
YRKS5002-6, 500KW, 10000V, 990r/min, ICW81A, IP44/IP54, F Insulation
YRKS5003-6, 560KW, 10000V, 990r/min, ICW81A, IP44/IP54, F Insulation
YRKS5004-6, 630KW, 10000V, 985r/min, ICW81A, IP44/IP54, F Insulation
YRKS5005-6, 710KW, 10000V, 990r/min, ICW81A, IP44/IP54, F Insulation
Optional Available
Customized frame size
Shaft : Special dimensions, double shaft end, tapered, hollow as per request
VFD application
Service Factor: 1.15 or above
Insulation Class : H (ΔT=105°K)
Ambient temperature : above 40 °C (on request)
Altitude above 1000 m (on request)
Mountings : B5, B35, V1
SKF, FAG, NSK bearing
Grease lubricated bearings
Space heaters
Thermostats RTD
Thermal protection PTC
Bearing thermometer with gauge with/without contact
Independent hydraulic oil circulation system for sleeve bearing
DE or both DE and NDE bearings are electrically insulated
Grounding brush on drive end bearing for all frames when driven by frequency converter (except for classified area)
Special Windings (Special Voltage & Frequency)
Typical Applications
Customized request
Blowers
Compressors
Conveyor
Cranes
Crushers
Elevators
Fans
Pumps
Grinders
Mills
Mixers
Presses
Ventilators
Agricultural machine
Brick machine
Cement machine
Centrifugal machine
Chemical machine
Food machine
Forging machine
Foundry machine
Hydraulic machine
Mine Machine
Metallurgy Machine
Machine tools
Packaging machine
Pellet machine
Plastic machine
Power plant
Refrigerating machine
Steel industry
Textile machinery
Transportation machinery
Others
Rated Output | : | 160~2,000 kW |
Poles | : | 2 ~ 12 poles |
Frequency | : | 50 Hz, 60 Hz |
Rated Voltage | : | 380 up to 13,800V |
Protection Class | : | IP44, IP54, IP55 |
Insulation Class | : | F, H |
Mounting Methods | : | B3, B5, B35, V1 |
Frame Size | : | 355~630 frame |
Housing Material | : | Die casted aluminum-alloy |
Brand Bearing | : | C&U, NSK, SKF, FAG |
Cooling Methods | : | IC411, IC416, IC611, IC616 |
3 Phase Squirrel Cage Induction Motor
High Power Asynchronous Squirrel Cage Compact Motor
Output : 160 up to 2,000 kW
Voltage : 380 up to 13,800 V
Frequency : 50 / 60 Hz
Poles : 2 up to 12 Poles
Protection Type : IP44, IP54, IP55
Service Factor : 1.00
Mountings: B3 (horizontal)
Frame :
Cast iron 315 up to 355 frame
Fabricated in welded steel 400 up to 630 frame
Insulation Class : F (ΔT=80°K)
Bearing type :
Ball bearing
Sleeve bearing
Bearing brand : Top quality one of Chinese bearing brand
Working Duty: S1 (Continuous)
Ambient Temperature : -15°C ~ 40°C
Altitude : 1000 m.a.s.l.
Ambient humidity : Lower than 90%
Cooling :
IC01 Open self-ventilated
IC411 Totally-enclosed, fan-cooled
IC416 Forced cooling by independent axial fan
IC511 Self-ventilated with air-to-air heat exchanger, heat exchanger around the stator
IC611 Self-ventilated with air-to-air heat exchanger, heat exchanger on top of motor
IC616 Forced ventilation in the air internal and external circuit, air-to-air heat exchanger
ICW81A Self-ventilated with air-to-water heat exchanger, heat exchanger on top of motor
Lubricating : With grease system
Grounding lug : on the frame and terminal box
Temperature detector : PT100
3 connection terminals in the power terminal box for high voltage (with terminal block)
6 loose power connection leads for low voltage (without terminal block)
Material of nameplate : Stainless steel
Metric Threaded Cable Entries on the Terminal Box
Motor color : RAL 6018 green or as per request
Dimensions : According to IEC-72
Performance Characteristics : According to IEC-34
Model |
Output |
Rated Current (A) |
Speed |
Eff. |
P. F. |
Tst |
Ist |
Tmax |
Vibration |
Noise |
F.T. |
Weight |
||||
kW |
3300V |
4160V |
6000V |
6600V |
r/min |
η% |
cos |
Tn |
In |
Tn |
mm/s |
dB (A) |
G.m2 |
kg |
||
Synchronous Speed 3000 r/min = 2-poles (50Hz) |
||||||||||||||||
Y2HV |
3551-2 |
185 |
41.0 |
32.6 |
22.6 |
20.5 |
2985 |
93.9 |
0.84 |
0.7 |
7.0 |
2.0 |
2.8 |
109 |
8 |
2035 |
Y2HV |
3552-2 |
200 |
44.3 |
35.2 |
24.4 |
22.2 |
2985 |
94.0 |
0.84 |
0.7 |
7.0 |
2.0 |
2.8 |
109 |
8.5 |
2075 |
Y2HV |
3553-2 |
220 |
48.6 |
38.6 |
26.8 |
24.3 |
2985 |
94.2 |
0.84 |
0.7 |
7.0 |
2.0 |
2.8 |
109 |
9.5 |
2160 |
Y2HV |
3554-2 |
250 |
55.2 |
43.8 |
30.3 |
27.6 |
2985 |
94.4 |
0.84 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
10 |
2215 |
Y2HV |
3555-2 |
280 |
60.2 |
47.8 |
33.1 |
30.1 |
2985 |
94.6 |
0.86 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
11 |
2280 |
Y2HV |
4001-2 |
315 |
67.6 |
53.6 |
37.2 |
33.8 |
2985 |
94.8 |
0.86 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
17 |
2630 |
Y2HV |
4002-2 |
355 |
76.1 |
60.4 |
41.9 |
38.1 |
2985 |
94.9 |
0.86 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
18 |
2700 |
Y2HV |
4003-2 |
400 |
85.6 |
67.9 |
47.1 |
42.8 |
2985 |
95.1 |
0.86 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
20 |
2830 |
Y2HV |
4004-2 |
450 |
96.2 |
76.3 |
52.9 |
48.1 |
2985 |
95.2 |
0.86 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
21 |
2920 |
Y2HV |
4501-2 |
500 |
105.5 |
83.7 |
58.0 |
52.8 |
2985 |
95.3 |
0.87 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
22 |
3200 |
Y2HV |
4502-2 |
560 |
118.0 |
93.6 |
64.9 |
59.0 |
2985 |
95.4 |
0.87 |
0.7 |
7.0 |
2.0 |
2.8 |
112 |
24 |
3300 |
Y2HV |
4503-2 |
630 |
132.7 |
105.2 |
73.0 |
66.3 |
2985 |
95.5 |
0.87 |
0.7 |
7.0 |
2.0 |
2.8 |
112 |
27 |
3500 |
Y2HV |
4504-2 |
710 |
149.2 |
118.4 |
82.1 |
74.6 |
2985 |
95.7 |
0.87 |
0.7 |
7.0 |
2.0 |
2.8 |
112 |
30 |
3600 |
Y2HV |
5001-2 |
800 |
166.4 |
132.0 |
91.5 |
83.2 |
2985 |
95.6 |
0.88 |
0.7 |
7.0 |
2.0 |
2.8 |
112 |
61 |
5360 |
Y2HV |
5002-2 |
900 |
187.0 |
148.3 |
102.8 |
93.5 |
2985 |
95.7 |
0.88 |
0.7 |
7.0 |
2.0 |
2.8 |
112 |
65 |
5500 |
Y2HV |
5003-2 |
1000 |
207.3 |
164.5 |
114.0 |
103.7 |
2985 |
95.9 |
0.88 |
0.7 |
7.0 |
2.0 |
2.8 |
112 |
69 |
5640 |
Y2HV |
5004-2 |
1120 |
231.9 |
184.0 |
127.6 |
116.0 |
2985 |
96.0 |
0.88 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
75 |
5700 |
Y2HV |
5601-2 |
1250 |
255.7 |
202.8 |
140.6 |
127.8 |
2985 |
96.1 |
0.89 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
111 |
5800 |
Y2HV |
5602-2 |
1400 |
285.8 |
226.7 |
157.2 |
142.9 |
2985 |
96.3 |
0.89 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
119 |
5860 |
Y2HV |
5603-2 |
1600 |
325.9 |
258.6 |
179.3 |
163.0 |
2985 |
96.5 |
0.89 |
0.7 |
7.0 |
2.0 |
2.8 |
111 |
127 |
5930 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model |
Output |
Rated Current (A) |
Speed |
Eff. |
P. F. |
Tst |
Ist |
Tmax |
Vibration |
Noise |
F.T. |
Weight |
||||
kW |
3300V |
4160V |
6000V |
6600V |
r/min |
η% |
cos |
Tn |
In |
Tn |
mm/s |
dB (A) |
G.m2 |
kg |
||
Synchronous Speed 1500 r/min = 4-poles (50Hz) |
||||||||||||||||
Y2HV |
3551-4 |
185 |
41.1 |
32.6 |
22.6 |
20.6 |
1488 |
93.7 |
0.84 |
0.8 |
6.5 |
2.0 |
2.8 |
106 |
19 |
2120 |
Y2HV |
3552-4 |
200 |
44.4 |
35.2 |
24.4 |
22.2 |
1488 |
93.9 |
0.84 |
0.8 |
6.5 |
2.0 |
2.8 |
106 |
22 |
2220 |
Y2HV |
3553-4 |
220 |
48.7 |
38.6 |
26.8 |
24.3 |
1488 |
94.1 |
0.84 |
0.8 |
6.5 |
2.0 |
2.8 |
106 |
23 |
2290 |
Y2HV |
3554-4 |
250 |
55.2 |
43.8 |
30.4 |
27.6 |
1488 |
94.3 |
0.84 |
0.8 |
6.5 |
2.0 |
2.8 |
108 |
25 |
2345 |
Y2HV |
3555-4 |
280 |
61.7 |
49.0 |
33.9 |
30.9 |
1488 |
94.5 |
0.84 |
0.8 |
6.5 |
2.0 |
2.8 |
108 |
26 |
2400 |
Y2HV |
4001-4 |
315 |
68.5 |
54.4 |
37.7 |
34.3 |
1488 |
94.6 |
0.85 |
0.8 |
6.5 |
2.0 |
2.8 |
108 |
32 |
2970 |
Y2HV |
4002-4 |
355 |
77.1 |
61.1 |
42.4 |
38.5 |
1488 |
94.8 |
0.85 |
0.8 |
6.5 |
2.0 |
2.8 |
108 |
34 |
3080 |
Y2HV |
4003-4 |
400 |
86.7 |
68.7 |
47.7 |
43.3 |
1488 |
95.0 |
0.85 |
0.8 |
6.5 |
2.0 |
2.8 |
108 |
37 |
3170 |
Y2HV |
4004-4 |
450 |
97.3 |
77.2 |
53.5 |
48.6 |
1488 |
95.2 |
0.85 |
0.8 |
6.5 |
2.0 |
2.8 |
108 |
39 |
3250 |
Y2HV |
4501-4 |
500 |
106.7 |
84.7 |
58.7 |
53.4 |
1488 |
95.3 |
0.86 |
0.8 |
6.5 |
2.0 |
2.8 |
108 |
52 |
3500 |
Y2HV |
4502-4 |
560 |
119.4 |
94.7 |
65.7 |
59.7 |
1488 |
95.4 |
0.86 |
0.8 |
6.5 |
2.0 |
2.8 |
111 |
58 |
3700 |
Y2HV |
4503-4 |
630 |
134.2 |
106.5 |
73.8 |
67.1 |
1488 |
95.5 |
0.86 |
0.8 |
6.5 |
2.0 |
2.8 |
111 |
65 |
3950 |
Y2HV |
4504-4 |
710 |
151.1 |
119.9 |
83.1 |
75.5 |
1488 |
95.6 |
0.86 |
0.8 |
6.5 |
2.0 |
2.8 |
111 |
73 |
4200 |
Y2HV |
5001-4 |
800 |
170.1 |
134.9 |
93.5 |
85.0 |
1488 |
95.7 |
0.86 |
0.8 |
6.5 |
2.0 |
2.8 |
111 |
130 |
5350 |
Y2HV |
5002-4 |
900 |
191.1 |
151.6 |
105.1 |
95.6 |
1488 |
95.8 |
0.86 |
0.8 |
6.5 |
2.0 |
2.8 |
111 |
141 |
5540 |
Y2HV |
5003-4 |
1000 |
212.1 |
168.3 |
116.7 |
106.1 |
1488 |
95.9 |
0.86 |
0.8 |
6.5 |
2.0 |
2.8 |
111 |
148 |
5700 |
Y2HV |
5004-4 |
1120 |
237.3 |
188.3 |
130.5 |
118.7 |
1488 |
96.0 |
0.86 |
0.8 |
6.5 |
2.0 |
2.8 |
113 |
156 |
5800 |
Y2HV |
5601-4 |
1250 |
261.6 |
207.5 |
143.9 |
130.8 |
1488 |
96.1 |
0.87 |
0.7 |
6.5 |
2.0 |
2.8 |
113 |
252 |
5900 |
Y2HV |
5602-4 |
1400 |
292.7 |
232.2 |
161.0 |
146.3 |
1488 |
96.2 |
0.87 |
0.7 |
6.5 |
2.0 |
2.8 |
113 |
272 |
5950 |
Y2HV |
5603-4 |
1600 |
333.8 |
264.8 |
183.6 |
166.9 |
1488 |
96.4 |
0.87 |
0.7 |
6.5 |
2.0 |
2.8 |
113 |
Standards
ABB motors are of the totally enclosed, three phase squirrelcage type, built to comply with international IEC andEN standards. Motors conforming to other national andinternational specifications are also available on request.
All production units are certified to ISO 9001 internationalquality standard as well ISO 1 4OO0 environmental standardand conformto all applicable EU Directives.
Voltage and Frequency
The impact on temperature rise caused by voltage andfrequency fluctuation is defined in lEC 60034-1.
The standard divides the combinations into two zones, zoneA and B. Zone A is the combination of voltage deviation+/-5% and frequency deviation +/-2%. Zone B is thecombination of voltage deviation +/-1O% and frequencydeviation +3%/-5%.
The motors are capable of supplying the rated torque in both zone A and B, but the temperature rise will be higher than atrated voltage and frequency. The motors are to be inoperation only for a short period of time in zone B.
Rated output
M2BAX motors rated outputs means that the motor runs undercontinuous duty S1 (IEC 60034-1) operation at ambient temperature from -20C ~40°C and at altitudes of up to 1000 mabove sea level.
Environmental
In accordance with IEC 60034-1, tolerance is the maximum allowed deviation betweenthe test result andthe declared value on the rating plate (orin the catalog).Test results are basedon test procedures in accordancewith IEC 60034-2-1,IEC 60034-9, and IEC 60034-12.
Overload time
According to IEC 60034, M2BAX motors are designed towithstand overload capacity of 1.5 times rated current for2 minutes at rated voltage and frequency.
Ambient temperatures and high altitudes
Normal motors are designed for operation at a maximumambient temperature of 40°C and at a maximum altitude of1000 meters above sea level.If a motor isoperated at higher ambient temperatures or altitude, it should be derated.
The best service from our transmission drive expert to your inbox directly.
Yantai Bonway Manufacturer Co.ltd
ANo.160 Changjiang Road, Yantai, Shandong, China(264006)
T+86 535 6330966
W+86 185 63806647