OMRON PLC Models

OMRON PLC Models

Omron PLC is a compact PLC with complete functions, which can provide high value-added machine control for the industry's leading transportation and decentralization control. Efficient software development capability under Windows environment.

CJ1, CP1, CPM1A-10CDR-A-V1, CPM1A-10CDR-D-V1, CPM1A-10CDT-D-V1, CPM1A-20CDR-A-V1, CPM1A-20CDR-D-V1, CPM1A-20CDT-D-V1, CPM1A-30CDR-A-V1, CPM1A-30CDR-D-V1, CPM1A-30CDT-D-V1, CPM1A-40CDR-A-V1, CPM1A-40CDR-D-V1, CPM1A-40CDT-D-V1, CPM1A-40EDR, CPM1A-20EDR1, CPM1A-8ER, CPM1A-8ED, CPM1A-40EDT, CPM1A-20EDT, CPM1A-8ET, CPM1A-MAD01-NL, CPM1A-MAD02-CH, CPM1A-DA001, CPM1A-DA002, CPM1A-AD041, CPM1A-DA041

1) N7X

Motion, Logic, Safety, Vision and HMI in one. A powerful and robust ONE automation platform. The NX-Series Machine Automation Controller is at the heart of the new Sysmac platform. Powerful Power Supply Unit to supply steady electric power to NX series controller.

2) NX1

Improves production efficiency while optimizing information, safety, and quality. Compact size controller that integrates production line and IT systems. A wide range of Digital Input/Output Units for any intended application. A wide range of Analog Input/Output Units for any intended application. Thermocouple-type and resistance-thermometer-type Temperature Control/Temperature Input/Heater Burnout Detection Unit with a wide variety of interfaces and Heater Burnout Detection Unit. Load cell input unit ideal for a cost saving weighing/measurement system. Position Interface Units for pulse output, encoder input, and SSI input. IO-Link master unit makes sensor level information visible and solves issues at manufacturing sites. Provides simplicity and flexibility in connecting serial devices to EtherCAT. Direct connection to RFID V680 amplifiers and antennas. Power Supply Units to add Unit power supply and I/O power supply for NX-series I/O Units. One connection using Safety over EtherCAT protocol enables flexible configuration by mixing the Safety Units with standard NX I/O.

3) NX1P

Advanced motion control and networks for onsite IoT in a compact entry model. Advanced motion control and networks for onsite IoT in a compact entry model. A wide range of Digital Input/Output Units for any intended application. A wide range of Analog Input/Output Units for any intended application. Thermocouple-type and resistance-thermometer-type Temperature Control/Temperature Input/Heater Burnout Detection Unit with a wide variety of interfaces and Heater Burnout Detection Unit. Load cell input unit ideal for a cost saving weighing/measurement system. Position Interface Units for pulse output, encoder input, and SSI input. IO-Link master unit makes sensor level information visible and solves issues at manufacturing sites. Provides simplicity and flexibility in connecting serial devices to EtherCAT. Direct connection to RFID V680 amplifiers and antennas. Power Supply Units to add Unit power supply and I/O power supply for NX-series I/O Units.

4) NJ

Motion, Logic, Safety, Vision and HMI in one. A powerful and robust ONE automation platform. The NJ-Series Machine Automation Controller is at the heart of the new Sysmac platform. Powerful Power Supply Unit to supply steady electric power to NJ series controller. Basic I/O Units are available for essentially any application and wiring method. Specialized I/O and communications units for temperature control, analog control, ID sensing and other types of machine control. Specialized I/O and communications units for DeviceNet, serial communications, and other network communications. I/O control units.

OMRON PLC Models

5) CP

Built-in Ethernet communication function and 4-axis positioning function to achieve high cost performance. Micro PLC ideal for controlling compact machine. 

6) CJ1

The CJ1 Series of small Programmable Controllers provide all the functions required for everything from machine control to process control in a backplane-free structure that enables flexible system configuration. Take a look at this overview of the entire CJ1 Series. Many models of CPU Units are available to handle anywhere from 160 to 2,560 I/O points. Models with built-in I/O are available to save even more space. A wide variation of Power Supply Units is available to match the scale of just about any system. Models are also available with a Replacement Notification function. Basic I/O Units are available for essentially any application and wiring method. Special I/O Units can be used to handle advanced machine control needs, such as temperature control, position control, and communications. CPU Bus Units handle special I/O and communications needs to achieve advanced position control, motion control, and network communications. Other Units are available for expansion racks and so on.

7) CJ2

Enhanced performance and functionality over the CJ1. A Programmable Controller that inherits all the features of the CJ1. CJ2 CPU Units provide all of this: Higher data memory capacity, Multifunctional Ethernet port, Tag access and USB port. Small, Fast, Flexible: The CJ2 CPU Units inherit and improve CJ1 features while also adding EtherNet/IP as a standard feature for high-speed, high-capacity Ethernet-based networking. A wide variation of Power Supply Units is available to match the scale of just about any system. Models are also available with a Replacement Notification function. Basic I/O Units are available for essentially any application and wiring method. Special I/O Units can be used to handle advanced machine control needs, such as temperature control, position control, and communications. CPU Bus Units handle special I/O and communications needs to achieve advanced position control, motion control, and network communications. Coupler Unit which enables EtherCAT or EtherNet/IP network communications. Other Units are available for expansion racks and so on.

8) CS1

The CS1 medium-sided building-block PLCs can be configured from a wide array of CPU Units, Special I/O Units, and CPU Bus Units. It handles everything from machine control to process control. Take a look at this overview of the entire CS1 Series. Basic I/O Units are available for essentially any application and wiring method. Special I/O Units can be used to handle advanced machine control needs, such as temperature control, position control, and communications. CPU Bus Units handle special I/O and communications needs to achieve advanced position control, motion control, and network communications. Coupler Unit which enables EtherCAT or EtherNet/IP network communications.

9) NSJ

This One-package Controller combines a touch panel with a controller.

OMRON PLC Models

Brand introduction:
Omron PLC is a compact PLC with complete functions, which can provide high value-added machine control for the industry's leading transportation and decentralization control. Efficient software development capability under Windows environment. Omron PLC can also be used in packaging systems and supports HACCP (parasitic pulse analysis critical control point) process processing standards.

1. Maintenance procedures, regular testing and adjustment of equipment
(1) Check the connection of the terminals in the PLC cabinet every six months or quarters, and if it is found to be loose, re-firm it in time
(2) Re-measure the working voltage of the power supply to the host in the cabinet every month.
2. Provisions for regular cleaning of equipment
(1) Clean the PLC every six months or quarters, cut off the power supply to the PLC, remove the power supply rack, CPU motherboard and input / output board in sequence, and then install them in situ after purging and cleaning. After all connections are restored, power on and start the PLC host. Carefully clean the sanitation in the PLC box;
(2) Replace the filter below the power supply rack every three months.
3. Preparation and maintenance procedures before maintenance
(1) Prepare tools before maintenance;
(2) In order to ensure that the function of the component does not fail and the template is not damaged, you must use protective devices and make anti-static preparations carefully;
(3) Contact the dispatcher and operator before overhaul, and the overhaul card should be hung at the overhaul board.
4. Equipment disassembly sequence and method
(1) When shutting down for maintenance, more than two persons must be monitored and operated;
(2) Turn the mode selection switch on the front panel of the CPU from "Run" to "Stop" position;
(3) Turn off the main power supply of PLC, and then turn off the other power supply to Mosaka;
(4) Remove the power cable connected to the power supply rack after clearing the line number and connection position, and then remove the screws connecting the power supply rack to the cabinet, and the power supply rack can be removed
(5) The CPU motherboard and I / 0 board can be removed after rotating the screws under the template;
(6) The installation is performed in reverse order.


V. Maintenance process and technical requirements
(1) When measuring voltage, use a digital voltmeter or a universal meter with an accuracy of 1%
(2) Both the power supply rack and the CPU motherboard can only be removed when the main power supply is cut off;
(3) Before the RAM module is removed from the CPU or inserted into the CPU, the power of the PC must be disconnected, so as to ensure that the data is not confused;
(4) Before removing the RAM module, check whether the module battery is working properly. If the battery fault light is on, the PAM content of the module will be lost;
(5) The main power supply should also be turned off before the input / output board is removed, but the I / 0 board can also be removed while the programmable controller is running if production requires, but the QVZ (timeout) light on the CPU board lights up;
(6) When inserting and inserting the template, take extra care, handle it gently, and keep it away from static-generating objects;
(7) The replacement components shall not be operated with power on;
(8) After the maintenance, the template must be installed in place.

Main feature:
① Flexible structure
Without being restricted by the environment, the network can be set up when power is available. At the same time, the number of access ports can be flexibly expanded to maintain a high utilization rate of resources, which is comparable to WLAN in terms of mobility.
② High transmission quality, fast speed and stable bandwidth
You can watch DVD movies smoothly online, and the 14Mbps bandwidth it provides can guarantee many application platforms. The latest powerline standard HomePlug AV transmission speed has reached 200Mbps; in order to ensure QoS, HomePlug AV uses Time Division Multiple Access (TDMA) and Carrier Sense Multiple Access (CSMA) protocol with collision detection function, a combination of both, It can transmit streaming media well.
③ Wide range
The ubiquitous power line network is also an advantage of this technology. Although the wireless network can be achieved without breaking the wall, for high-rise buildings, it is necessary to deploy N multiple APs to meet the demand, and also the existence of signal blind spots cannot be avoided. The power line is the most basic network, and its scale is unmatched by any other network. As a result, operators can easily infiltrate this network access service everywhere where there is a power line. Once this technology fully enters the commercial stage, it will bring great development space to the popularity of the Internet. End users only need to plug in a power cat to achieve Internet access, receive TV channels, make calls or make video calls.
④ Low cost
Make full use of the existing low-voltage power distribution network infrastructure, without any wiring, saving resources. There is no need to dig trenches and holes through walls, avoiding damage to buildings, public facilities and home decoration, and at the same time saving manpower. Compared with the traditional networking technology, PLC has lower cost, shorter construction period, and stronger scalability and manageability. At present, where the domestic broadband Internet access has been opened, the monthly usage fee is generally around 50-80 yuan / month, which is the same as that of the ADSL monthly subscription in many places.
⑤ Wide application
As an access technology that utilizes power line networking, PLC provides a "last mile" solution for broadband networks, and is widely used in residential areas, hotels, office areas, and monitoring and security fields. It uses power line as a communication carrier, which makes PLC extremely convenient. As long as there is a power outlet anywhere in the room, without dialing, you can immediately enjoy 4.5 ~ 45Mbps high-speed Internet access to browse the web and make calls. And watch online movies, so as to realize the integration of data, voice, video, and power in the "four networks in one."
The new trend of plc development PLC is a kind of electronic device specially designed for application in industrial environment. It uses programmable memory to store internal instructions for performing logical operations, sequential operations, timing, counting, and arithmetic operations, and can control various types of inputs through digital or analog inputs and outputs. Mechanical or production process. PLC has been widely used in various industries such as steel, petroleum, chemical industry, electric power, building materials, machinery manufacturing, automobile, textile, transportation, environmental protection and cultural entertainment. It has high reliability, strong anti-interference ability, powerful function and flexibility. It is easy to learn, easy to use, small, light and cheap.

OMRON PLC Models

Omron C series P type machine has three types: basic type, extended type and special type. There are 4 kinds of CPU mainframes, 6 kinds of I / O short-range expansion machines, and a variety of special units.

The micro PLC with integral structure is a model represented by C20P. The CJ type is the most typical microcomputer with a stacked (or compact) structure. It has ultra-small size and ultra-thin size. The small PLC machine is the most typical of P-type machine and CPM-type machine, both of which are of solid overall structure. It has smaller size, richer commands, and superior performance. It can realize flexible configuration of 10 ~ 140 input and output points through I / O expansion, and can be connected to a programmable terminal to program directly from the screen. CPM machine is OMRON Users currently choose the most small series products. The C200H series is the most typical OMRON medium-sized machine, mainly including C200H, C200HS, C200HX, C200HG and C200HE. 

The model of C series is generally CXXPXX-XXX-X, from left to right, X is (1) (2) (3)
1. The basic unit The basic unit (also called the host) has a CPU, where C represents the series code; (1) indicates the total number of input and output points, mainly 20, 28, 40, 60 points; (2) P means pocket Ladder diagram programming mode, PE stands for pocket ladder diagram programming mode; (3) is the unit type represented by one letter, C represents the basic unit, E represents the expansion unit with input and output points, I represents the expansion unit with input points , O represents an expansion unit with only an output point, TM represents an analog timer unit; (4) is a letter indicating the type of input loop power supply, such as A means AC 100V, D means DC 24V power supply; (5) output with a letter Type, R represents the relay contact output with socket, R1 represents the relay contact output without socket, T represents the transistor output, S represents the bidirectional thyristor output; (6) uses a letter to indicate the power supply type, A represents 100 ~ 240V AC power supply , D means DC 24V.
Note that for the number of input points, if it is a DC input type, it is the number of points in the table, if it is an AC input type, the AC input point minus 2. Another 2 points are DC 24V input.

2. Expansion I / O unit The expansion unit is divided into an I / O expansion unit and a single expansion unit. The gas model and meaning are as follows:
Among them, C is the series code; (1) represents the expansion points; (2) I represents the expansion input, O represents the expansion output, E represents the input and output expansion; (3) represents the input power source type or the output type, which means (2) Only when combined with the two letters of (3) can the complete meaning be expressed. For example, ID means DC expansion, OR means relay contact output expansion, etc.
There are 6 varieties of I / O expansion unit: C4K, C16P, C20P, C28P, C40P, C60P. For example, C28P-EDS-A indicates that it is an AC-powered C series P-type expansion unit with 16 DC 24V input points and 24 bidirectional thyristor output points. C4K-ID indicates an expansion unit with 4 points and 2V input points.

3. Dedicated unit Dedicated unit is used to expand other functions, occupying I / O address. Special units include analog timing unit, analog input, output unit and I / O connection unit.
Omron's small PLC is generally an overall structure. A control system that can be flexibly combined with 4 types of CPU units and 6 types of I / O expansion units as needed, can meet the needs of the vast majority!

OMRON PLC Models

Main technical parameters of OMRON C series PLC:
1. Brief introduction of input technical characteristics For DC input type, input DC voltage is 24V, input impedance 3kΩ, input
Current 7mA, turn-on and turn-off response time is less than or equal to 2.5ms, input circuit has photoelectric isolation ... The power supply voltage is AC 100 ~ 240V, DC 24V.
For the AC input type, the input voltage is 100 ~ 120V, the input impedance is 9.7kΩ (50Hz), 8kΩ (60Hz), the input current is 10mA, the turn-on response time is less than 35ms, and the turn-off response time is less than 55ms. Photoelectric isolation. Power supply voltage AC 100 ~ 240V, DC 24V.
2. Introduction of output technical characteristics For the R contact output of the relay, the turn-on and turn-off response time are below 15ms. The output loop is isolated by the relay. The power supply voltage is AC 100 ~ 240V, DC 24V, and can drive AC or DC loads. For the transistor T output, the turn-on and turn-off response time are less than 1.5ms, and the output loop has photoelectric isolation, which can drive a DC load.
For the bidirectional thyristor S output, the turn-on response time is less than 1.5ms, the turn-off time is less than (load frequency / 2 ten 1ms), there is photoelectric isolation, suitable for AC loads.
Regardless of the output method, the load power is provided by the user.

Programmable Logic Controllers, along with easy-to-use Support Software, are available to flexibly handle applications from small-scale equipment to entire production lines with Programmable Logic Controllers such as those in the CJ1, CS1 and other series.

OMRON PLC Models

 Geared Motors And Electric Motor Manufacturer

The best service from our transmission drive expert to your inbox directly.

Get in Touch

Yantai Bonway Manufacturer Co.ltd

ANo.160 Changjiang Road, Yantai, Shandong, China(264006)

T+86 535 6330966

W+86 185 63806647

© 2024 Sogears. All Rights Reserved.