Modular induction motors, type AMI
The AMI motors meets NEMA electrical performance requirements and mechanical mounting standards while providing the energy-efficient operation, sustainable design and quality manufacturing processes ABB is known for.

The type designation of the AMI motor follows the coding principle shown below.
Example: AMI 450L4A BATH
1 AM
General type designations
2
I
Indicates the type of motor, A, I = SCIM, K, L = WRIM
3
450
Shaft centre height in mm; 355, 400, 450, 500, 560, 630
4
L
Frame length, S = small, M = medium or L = long
5
4
Number of poles
6
A
Stands for the IC/IP combination
A = IC611 / IP54 (55) [TEAAC] air-to-air cooled
D = IC01 / IP23 [WP I] open ("drip proof")
L = IC81W / IP54 (55) [TEWAC] air-to-water cooled
P = IC11, 21, 31 / IP23, 54, (55) [OPV, TEPV] pipe ventilated
W = IC01 / IPW24 [WP II] weather protected
7
B
Mounting arrangement, B = IM1001 (horizontal), V = IM4011 (vertical)
8
A
Bearing type, A = antifriction, S = sleeve
9
T
Indication of special construction
T = separate ventilation
M = marine application
Y = mechanically special
F = frequency converter drive X = electrically special
Z = special material specs
10
H
Location of manufacture

—
Modular induction motors, type AMI
Enclosure and cooling
—
21
IC01 / IP24
—
22
IC611 / IP55
—
23
IC81W / IP55
—
24
IC31 / IP55
—
25
IC01
Standard combinations for AMI motors:
IC01 / IP24
This weather protected motor has a shaft
mounted cooling fan inside the housing.
The design of the motor reduces the ingress
of rain, snow and airborne particles into the
electrical parts. On the air intake path this is
achieved by ensuring that the average velocity
does not exceed 3 m/s, allowing any heavier
particles to settle. The design of the air intake
path includes three acute direction changes
in excess of 90 degrees to further reduce the
flow rate to the optimal level. The motor is
protected against splashing water from any
direction.
IC611 / IP55
This design has an air-to-air heat exchanger
mounted on the motor, which is fully enclosed.
Shaft mounted fans are fitted both inside and
outside of the casing to supply the inside and
outside cooling circuits respectively. The motor
is protected against dust and splashing water
from any direction.
IC81W / IP55
This fully enclosed motor is fitted with an
air-to-water heat exchanger. A shaft mounted fan
is fitted inside the casing to supply the internal
cooling circuit. The motor is protected against
dust and splashing water from any direction.
The terminal boxes have a protection rating of
at least IP55.
IC31 / IP55
This version is fitted with inlet and outlet pipes
to use remote cooling air. Essentially this is
the AMI motor frame without an upper cover.
The motor is protected against dust and
splashing water from any direction.
IC01
IC01 with asymmetric inside air circulation.
—
21
—
22
—
23
—
24
—
25
56
H I G H VOLTAG E E NG I N E E R E D I N DUC TI ON MOTOR S TECHNIC A L C ATA LOG

—
Modular induction motors, type AMI
Mounting arrangements
—
19
Code I: IM B3
Code II: IM 1001
Horizontal foot mounted
—
20
Code I: IM V1
Code II: IM 4011
Vertical flange mounted
(free shaft end facing
downwards)
Standard mounting arrangements for AMI motors. Other mountings available on request.
55

—
Modular induction motors, type AMI
Dimension drawings
—
Antifriction bearings, 1 < UN ≤ 6.6 kV, IM 1001, IC611 / IP55
Table gives main dimensions in mm.
AMI
Poles
A
B
C
D
E
F
G
H
K
L
AA
AB
AC
AD
400L
2
750
1250
200
85
170
22
76
400
35
2290
150
880
855
335
400L
≥ 4
750
1250
200
110
210
28
100
400
35
2330
150
880
855
335
450L
2
850
1400
200
90
170
25
81
450
42
2480
150
980
905
335
450L
≥ 4
850
1400
200
125
210
32
114
450
42
2520
150
980
905
335
500L
≥ 4
950
1600
200
140
250
36
128
500
42
2830
150
1080
955
335
560L
≥ 6
1180
2000
250
180
300
45
165
560
42
3395
200
1320
1285
545
630L
≥ 6
1400
2240
250
200
350
45
185
630
42
3685
200
1500
1375
545
AMI
Poles
AE
BA
BB
BC
GD
HA
HB
HC
LD
LE
HU
D-end bearing
N-end bearing
400L
2 1400
545 1450
445
14
20
130 1590
615 1480
565
6319M/C3
6319M/C3
400L
≥ 4 1400
545 1450
445
16
20
130 1590
655 1520
565
6324/C3
6319/C3
450L
2 1500
575 1600
465
14
25
230
1760
710
1630
665
6319M/C3
6319M/C3
450L
≥ 4 1500
575 1600
465
18
25
230
1760
750
1670
665
6326/C3
6322/C3
500L
≥ 4 1605
645 1800
495
20
35
330 1960
860
1910
765
6330/C3
6324/C3
560L
≥ 6
2125
400 2230
400
25
65.5
75
2100
765
2435
798
6038/C3+NU1038/C3
NU1038/C3
630L
≥ 6 2305
400
2470
400
25
65.5
225 2320
815
2725
948
6044/C3+NU1044/C3
NU1044/C3
Key benefits
ABB is the world's leading supplier of medium-voltage squirrel cage motors and speed controllers. These motors are practically used in a wide range ABB High Voltage Motors ; Output power, 140 to 28,500 kW at 50 Hz 200 to 38,000 HP at 60 Hz ; Frame size, IEC 400 to 1,000.
Reduce operating costs by utilizing energy efficiency that meets or exceeds NEMA electrical and mechanical performance values
AMI engineered modular induction motors provide reliability and availability in the toughest and most demanding applications. Engineered modular induction motors are tailormade to meet the needs of each customer and each application. Built from the motor industry’s most successful modular platform, they match a broad variety of demanding application requirements while having the flexibility to be adapted to highly specific configurations.
Here is a example: ABB AMI 450L6L BAFTMH INDUCTION MOTOR TYPE:- AMI 450L6L BAFTMH BAFTMH YEAR 2011 3 PHASES WEIGHT 4480 KG OUTPUT 1470 KW VOLTAGE 440 V CURRENT 2281 A POWER FACTOR 0.88 FREQUENCY 60.4 HZ RPM 1199.8 COOLING WATER FLOW8.2 3/H COOLING WATER TEMP 38c AMBIENT 45C


Main features
AMI modular induction motors have a welded steel frame. They are available with the following cooling methods and protection types as standard: IC01/IP24W, IC611/IP55 and IC81W/IP55. The standard shaft heights are 400 to 630 mm. The motors can be mounted horizontally or vertically.
For AMI motors this catalog shows the technical data at 50 Hz only, but these motors are operating at both 50 Hz and 60 Hz, with synchronous speed from 500 to 3600 rpm. Output powers for AMI motors covered in this catalogue are up to 8,000 kW, while the complete range goes up to 23,000 kW.
AMI engineered modular induction motors provide reliability and availability in the toughest and most demanding applications.
Engineered modular induction motors are tailormade to meet the needs of each customer and each application. Built from the motor industry’s most successful modular platform, they match a broad variety of demanding application requirements while having the flexibility to be adapted to highly specific configurations.
ABB’s modular induction motors comply with all relevant international standards. Versions are available for both direct-on-line (DOL) and variable speed drive (VSD) operation.
Other Types Of ABB Motors
Used in various industrial and commercial applications, including pumps, fans, conveyors, and compressors.
Fabricated Aluminum bar as standard (Copper or Copper alloy bar available)
Bars fixed to slots by swaging
Rotor balanced with half key acc. ISO 1940/1