1,Support Applicable motors: AC induction motor, permanent magnet synchronous motor (PMSM)
2 High performance open loop and close loop vector control (support different kinds of encoders)
3.High torque control in low frequency 0.5Hz/150%(SVC), and 0Hz/180%(FVC)
real vector control with three hall sensor current detecting
4.Support 2 analog input 0-10v 4-20MA and two analog output as well as support IO expansion card
5. Protections: Over-voltage stall, under-voltage, current limit, overload, overheat, over speed, over-voltage, etc.
6.Support PID with fastest response
7 Support RJ45 Cables and standard keypad support 100m control
8 fast auto tuning less than 1 minutes
Item |
Specifications |
||
Standard functions |
Maximum frequency |
0~3200.00Hz |
|
Carrier frequency |
0.5–16 kHz(The carrier frequency is automatically adjusted based on the load features.) |
||
Input frequency resolution |
Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.025% |
||
Control mode |
Sensor-less flux vector control (SFVC) Closed-loop vector control (CLVC) (+PG Card) Voltage/Frequency (V/F) control |
||
Startup torque |
G type: 0.3Hz/150% (SFVC) ; 0 Hz/180% (CLVC) P type: 0.5Hz/100% |
||
Speed range |
1: 200 (SFVC) |
1:1000 (CLVC) |
|
Speed stability accuracy |
± 0.5% (SFVC) |
± 0.02% (CLVC) |
|
Torque control accuracy |
±5% (CLVC) |
||
Overload capacity |
G type: 60s for 150% of the rated current, 3s for 180% of the rated current P type: 60s for 120% of the rated current, 3s for 150% of the rated current |
||
Torque boost |
Auto boost; Manual boost: 0.1%~30.0% |
||
V/F curve |
Straight-line V/F curve Multi-point V/F curve N-powerV/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) |
||
V/F separation |
Two types: complete separation; half separation |
||
Acceleration/deceleration curve |
Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.00s~65000s |
||
Standard functions |
DC braking |
DC braking frequency: 0.00 Hz ~ maximum frequency Braking time: 0.0~100.0s Braking trigger current value: 0.0%~100.0% |
|
JOG control |
JOG frequency range: 0.00Hz~50.00 Hz JOG acceleration/deceleration time: 0.00s~65000s |
||
Built-in PLC, multiple speeds |
It realizes up to 16 speeds via the simple PLC function or combination of DI terminal states. |
||
Built-in PID |
It realizes closed loop control system easily. |
||
Auto voltage regulation (AVR) |
It can keep constant output voltage automatically when the mains voltage fluctuation. |
||
Overvoltage/ Over current stall control |
The current and voltage are limited automatically during the running process so as to avoid frequently tripping due to overvoltage/over current. |
||
Rapid current limit function |
It can auto limit running current of frequency inverter to avoid frequently tripping. |
||
Torque limit and control |
(Excavator characteristics) It can limit the torque automatically and prevent frequently over current tripping during the running process. Torque control can be implemented in the VC mode. |
||
Individualized functions |
High performance |
Control of asynchronous motor is implemented through the high-performance current vector control technology. |
|
Instant power off not stop |
The load feedback energy compensates the voltage reduction so that the frequency inverter can continue to run for a short time. |
||
Rapid current limit |
To avoid frequently over current faults of the frequency inverter. |
||
Timing control |
Time range: 0.0~6500.0 minutes |
||
Multiple communication protocols |
Currently supports communication bus via Modbus-RTU and later will support PROFIBUS-DP, CANopen, etc. |
||
Motor overheat protection |
The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100, PT1000) so as to realize motor overheat protection. |
||
Multiple encoder types |
It supports incremental encoder and encoders such as differential encoder, open-collector encoder, resolver, UVW encoder, and SIN/ COS encoder. |
||
Advanced background software |
It supports the operation of frequency inverter parameters and virtualoscillograph function, by which the state of frequency invertercan be monitored. |
||
Run |
Running command giving |
key panel Control terminals Serial communication port You can switch between these giving in various ways. |
The Performance of JAC 580
Support the vector control for various motors.
The newest non-speed sensor vector control
Characteristics of high starting torque and superior responsiveness
Technical Specification
Item |
Specification |
||
Standard functions |
Maximum frequency |
Vector contro: 0~300Hz; V/F control: 0~3200Hz |
|
Carrier frequency |
0.5kHz~16kHz The carrier frequency is automatically adjusted based on the load features. |
||
Input frequency resolution |
Digital setting: 0.01Hz Analog setting: maximum frequency x 0.025% |
||
Control mode |
• Sensorless flux vector control (SFVC) • Closed-loop vector control (CLVC) • Voltage/Frequency (V/F) control |
||
Starting torque |
• G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC) • P type: 0.5 Hz/100% |
||
Basic functions |
Speed range |
1:100 (SFVC) |
1:1000 (CLVC) |
Constant-speed accuracy |
± 0.5% (SFVC) |
± 0.02% (CLVC) |
|
Torque control accuracy. |
± 5% (CLVC) |
||
Overload capacity |
• G type: 60s for 150% of the rated current, 3s for 180% of the rated current • P type: 60s for 120% of the rated current, 3s for 150% of the rated current |
||
Torque boost |
•Fixed boost • Customized boost 0.1%–30.0% |
||
V/F curve |
• Straight-line V/F curve • Multi-point V/F curve •N-power V/F curve (1.2-power, 1.4-power, 1.6-power, ,1.8-power, square) |
||
V/F separation |
Two types: complete separation; half separation |
||
Acceleration /deceleration curve |
•Straight-line ramp • S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0–6500.0s |
||
DC braking. |
DC braking frequency: 0.00Hz~maximum frequency Braking time: 0.0s~36.0s Braking action current value: 0.0%–100.0% |
||
JOG control |
JOG frequency range: 0.00–50.00 Hz JOG acceleration/deceleration time: 0.0–6500.0s |
||
Simple PLC and multi-speed operation |
It implements up to 16 speeds via the simple PLC function or combination of DI terminal states. |
||
Onboard PID |
It realizes process-controlled closed loop control system easily. |
||
Automatic voltage regulation (AVR) |
It can keep constant output voltage automatically when the mains voltage changes. |
||
Overvoltage/ Overcurrent stall contro |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/overcurrent. |
||
Quick current limiting |
Maximize overcurrent failure and protect the frequency converter in normal operation |
||
Torque limit and control |
It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the CLVC mode. |
||
Individualized functions |
High performance |
Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology. |
|
Power dip ride through |
The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. |
||
Rapid current limit |
It helps to avoid frequent overcurrent faults of the AC drive. |
||
Timing control |
Time range: 0.0–6500.0 minutes |
||
Multi-motor switchover |
Four motors can be switched over via four groups of motor parameters. |
||
Bus support |
Support field bus: Modbus |
||
Motor overheat protection |
The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100, PT1000) so as to realize motor overheat protection. |
||
Multiple encoder types |
Support difference, open collector and rotary transformer |
||
Operation |
Command source |
Operation panel, control terminal and serial communication port are given Switch in various methods |
|
Frequency source |
Various frequency sources: digital reference, analog voltage reference, analog current reference, pulse reference and serial port reference. The switching can be conducted in various methods |
||
Auxiliary frequency source |
10 kinds of auxiliary frequency source. The auxiliary frequency jog and frequency synthesis can be achieved flexibly |
||
Input terminal |
Standards: 7 digital input terminals, among which one support maximum high-speed pulse input of 100kHz 2 analog input terminals, among which one only supports voltage input of 0 ~10V and the other supports voltage input of 0 ~10V or current input of 4 ~20mA Expansion capability: 3 digital input terminals 1 analog input terminal, which supports voltage input of -10V ~10V and supports PT100/PT1000 |
||
Operation |
Output terminal |
Standards: 1 high-speed pulse output terminal (The open collector type is optional), supporting 0~100kHz square signal output 1 digital output terminal 1 relay output terminal 1 analog output terminal, supporting current outpout of 0~20mA or voltage output of 0~10V Expansion capability: 1 digital output terminal 1 relay output terminal 1 analog output terminal, supporting current output of 0~20mA or voltage output of 0~10V |
|
Display and keyboard operation |
LED display |
Display the parameter |
|
Key lock and function selection |
Realize partial or all key lock and define the action range of some keys to prevent misoperation |
||
Protection function |
Short circuit test of electrified motor, input/output default phase protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, etc. |
||
Options |
IO expansion card, differential input PG card, OC input PG card and rotary transformer PG card. |
||
Environment |
Service site |
Indoor, free from direct sunshine, no dust, corrosive gas, combustible gas, oil fog, water vapor, drip or salt, etc. |
|
Altitude |
Less than 1,000m |
||
Ambient temperature |
-10℃~ +40℃ (Please use the equipment by derating at ambient temperature of 40℃~50 ℃) |
||
Humidity |
Less than 95%RH, no water condensation |
||
Vibration |
Less than 5.9m/s2(0.6g) |
||
Storage temperature |
-20℃~ +60℃ |
||
IP grade |
IP20 |
||
Pollution level |
PD2 |
||
Power distribution system |
TN , TT |
The best service from our transmission drive expert to your inbox directly.
Yantai Bonway Manufacturer Co.ltd
ANo.160 Changjiang Road, Yantai, Shandong, China(264006)
T+86 535 6330966
W+86 185 63806647